LC-ESI-MS/MS Method for the Fosamprenavir Quantification Bioanalytical Method Development and Validation for the Quantification Fosamprenavir in Human Plasma by LC-ESI-MS/MS

被引:2
|
作者
Susmitha, Kondam [1 ]
Menaka, Muthukkarupan [2 ]
机构
[1] Annamalai Univ, Dept Pharmaceut Chem, Chidambaram, Tamil Nadu, India
[2] Annamalai Univ, Dept Pharmaceut, Chidambaram, Tamil Nadu, India
关键词
Fosamprenavir; Protease inhibitor; LC-MS/MS; FDA guidelines; Acuuracy; RITONAVIR; LOPINAVIR; PROTEASE;
D O I
10.5530/ijper.56.3s.168
中图分类号
G40 [教育学];
学科分类号
040101 ; 120403 ;
摘要
Objectives: The main goal of the current research was to develop a bioanalytical technique for the quantification of fosamprenavir in plasma by LC-ESI-MS/MS. Materials and Methods: Chromatographic elution was attained thru a Zorbax (3.5 mu m; 50 x 4.6 mm) analytical C-18-column with isocratic system by methanol, 0.1 %v/v formic acid and acetonitrile in the ratio of 60:10:30 V/V as mobile phase with flowrate of 0.70 ml/min. Liquid-liquid extraction was executed for the drug separation with an ethyl acetate solvent. Parent and product ions were monitored at m/z 586.19 /57.0 for Fosamprenavir and 590.0/61.0 for Fosamprenavir-D4 on MRM. Results: Linearity plot of fosamprenavir was rectilinear over the concentration of 4.0- 1600.0 ng/ml with correlation coefficient (r(2)) value of more than 0.99. The developed procedure has fine recovery with percentage recovery findings of HQC, MQC and LQC standards were present between 89.65% to 95.61 %. The % RSD findings were < 6.30% for intra-day and inter-day accuracy and precision. Conclusion: Fosamprenavir has more stability for longer time when subjected for different stability environments and the technique was effectively relevant to routine analysis of fosamprenavir in biological matrix.
引用
收藏
页码:S599 / S604
页数:6
相关论文
共 50 条
  • [1] A Sensitive Bioanalytical Method Development And Validation Of Pazopanib In Human Plasma By LC-ESI-MS/MS
    Annapurna, M.
    Shanthi, Priya D. K.
    JOURNAL OF PHARMACEUTICAL NEGATIVE RESULTS, 2022, 13 : 855 - 861
  • [2] A sensitive bioanalytical method development and validation of cabozantinib in human plasma by LC-ESI-MS/MS
    Inturi, Srikanth
    Avula, Prameela Rani
    BRAZILIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2018, 54 (02)
  • [3] Method Development and Validation for the Quantification of Abametapir in Biological Matrices by LC-ESI-MS/MS
    Krishnan, Vinayaga Sundaram
    Bhikshapathi, Darna
    Cheruku, Shankar
    INDIAN JOURNAL OF PHARMACEUTICAL EDUCATION AND RESEARCH, 2024, 58 (03)
  • [4] Development and Validation of LC-ESI-MS Method for the Quantification of Dapoxetine in Rat Plasma
    Wang, Zhiyi
    Wang, Zhibin
    Chen, Chan
    Wang, Jinjin
    Luo, Shunbin
    Ma, Jianshe
    LATIN AMERICAN JOURNAL OF PHARMACY, 2012, 31 (01): : 5 - 9
  • [5] Development and Validation of a LC-ESI-MS/MS Based Bioanalytical Method for Dapagliflozin and Saxagliptin in Human Plasma
    Goday, Swapna
    Shaik, Abdul Rahaman
    Avula, Prameelarani
    INDIAN JOURNAL OF PHARMACEUTICAL EDUCATION AND RESEARCH, 2018, 52 (04) : S277 - S286
  • [6] Development and Validation of LC-ESI-MS/MS Method for the Determination of Alfuzosin in Human Plasma
    Rania M. Moustapha E. Moustapha
    Mehnaz El Gamal
    Journal of Analytical Chemistry, 2021, 76 : 1327 - 1335
  • [7] Development and Validation of LC-ESI-MS/MS Method for the Determination of Alfuzosin in Human Plasma
    Moustapha, Moustapha E.
    El Gamal, Rania M.
    Kamal, Mehnaz
    JOURNAL OF ANALYTICAL CHEMISTRY, 2021, 76 (11) : 1327 - 1335
  • [8] A sensitive LC-ESI-MS/MS method for the quantification of low concentrations of buspirone in human plasma
    Joshi, Pankaj
    Rao, Shireen
    Singh, Manoj
    Vig, Nitin
    Singh, Abhay Kant
    Rajawat, Narendra Singh
    Gupta, Ankush
    ANALYTICAL METHODS, 2013, 5 (24) : 7014 - 7021
  • [9] Rapid, simple and highly sensitive LC-ESI-MS/MS method for the quantification of tamsulosin in human plasma
    Ramakrishna, NVS
    Vishwottam, KN
    Manoj, S
    Koteshwara, M
    Wishu, S
    Varma, DP
    BIOMEDICAL CHROMATOGRAPHY, 2005, 19 (10) : 709 - 719
  • [10] LC-ESI-MS/MS method for the quantification of entecavir in human plasma and its application to bioequivalence study
    Challa, Balasekhara Reddy
    Awen, Bahlul Z.
    Chandu, Babu Rao
    Rihanaparveen, Shaik
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (11-12): : 769 - 776