ADAPTIVE PLANNING IN INTENSITY-MODULATED RADIATION THERAPY FOR HEAD AND NECK CANCERS: SINGLE-INSTITUTION EXPERIENCE AND CLINICAL IMPLICATIONS

被引:97
|
作者
Ahn, Peter H. [1 ,2 ]
Chen, Chin-Cheng [1 ,2 ]
Ahn, Andrew I. [2 ]
Hong, Linda [1 ,2 ]
Scripes, Paola G. [1 ,2 ]
Shen, Jin [1 ,2 ]
Lee, Chen-Chiao [1 ,2 ]
Miller, Ekeni [1 ,2 ]
Kalnicki, Shalom [1 ,2 ]
Garg, Madhur K. [1 ,2 ]
机构
[1] Yeshiva Univ, Montefiore Med Ctr, Dept Radiat Oncol, Bronx, NY USA
[2] Yeshiva Univ, Albert Einstein Coll Med, Bronx, NY USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2011年 / 80卷 / 03期
关键词
Radiotherapy; Head-and-neck tumor; Positional change; Anatomic change; Dosimetry; RADIOTHERAPY; IMRT;
D O I
10.1016/j.ijrobp.2010.03.014
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Anatomic changes and positional variability during intensity-modulated radiation therapy (IMRT) for head and neck cancer can lead to clinically significant dosimetric changes. We report our single-institution experience using an adaptive protocol and correlate these changes with anatomic and positional changes during treatment. Methods and Materials: Twenty-three sequential head and neck IMRT patients underwent serial computed tomography (CT) scans during their radiation course. After undergoing the planning CT scan, patients underwent planned rescans at 11, 22, and 33 fractions; a total of 89 scans with 129 unique CT plan combinations were thus analyzed. Positional variability and anatomic changes during treatment were correlated with changes in dosimetric parameters to target and avoidance structures between planning CT and subsequent scans. Results: A total of 15/23 patients (65%) benefited from adaptive planning, either due to inadequate dose to gross disease or to increased dose to organs at risk. Significant differences in primary and nodal targets (planning target volume, gross tumor volume, and clinical tumor volume), parotid, and spinal cord dosimetric parameters were noted throughout the treatment. Correlations were established between these dosimetric changes and weight loss, fraction number, multiple skin separations, and change in position of the skull, mandible, and cervical spine. Conclusions: Variations in patient positioning and anatomy changes during IMRT for head and neck cancer can affect dosimetric parameters and have wide-ranging clinical implications. The interplay between random positional variability and gradual anatomic changes requires careful clinical monitoring and frequent use of CT- based image-guided radiation therapy, which should determine variations necessitating new plans. (C) 2011 Elsevier Inc.
引用
收藏
页码:677 / 685
页数:9
相关论文
共 50 条
  • [41] Intensity modulated radiation therapy for head and neck cancer: The standard
    Maingon, P.
    Crehange, G.
    Chamois, J.
    Khoury, C.
    Truc, G.
    CANCER RADIOTHERAPIE, 2011, 15 (6-7): : 473 - 476
  • [42] Quality assurance of intensity modulated radiation therapy treatment planning using head and neck phantom
    Zahra
    Rehman, Jalil ur
    Asghar, H. M. Noor ul Huda Khan
    Ahmad, Nisar
    Gilani, Zaheer Abbas
    Nasar, Gulfam
    Akhter, Malik M.
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2019, 18 (03) : 239 - 245
  • [43] Effectiveness of radiotherapy for head and neck skin cancers: a single-institution study
    Kim, Jae Wang
    Yun, Byung Min
    Shin, Myoung Soo
    Kang, Jae Kyoung
    Kim, JungJu
    Kim, Young Suk
    RADIATION ONCOLOGY JOURNAL, 2019, 37 (04): : 293 - 301
  • [44] Fentanyl pectin nasal spray for painful mucositis in head and neck cancers during intensity-modulated radiation therapy with or without chemotherapy
    R. Mazzola
    F. Ricchetti
    A. Fiorentino
    N. Giaj-Levra
    S. Fersino
    U. Tebano
    S. Albanese
    S. Gori
    F. Alongi
    Clinical and Translational Oncology, 2017, 19 : 593 - 598
  • [45] On the value of a multistage optimization approach for intensity-modulated radiation therapy planning*
    Wood, Doran
    Cetinkaya, Sila
    Gangammanavar, Harsha
    Lu, Weigo
    Wang, Jing
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (14)
  • [46] Fentanyl pectin nasal spray for painful mucositis in head and neck cancers during intensity-modulated radiation therapy with or without chemotherapy
    Mazzola, R.
    Ricchetti, F.
    Fiorentino, A.
    Giaj-Levra, N.
    Fersino, S.
    Tebano, U.
    Albanese, S.
    Gori, S.
    Alongi, F.
    CLINICAL & TRANSLATIONAL ONCOLOGY, 2017, 19 (05) : 593 - 598
  • [47] Intensity-modulated proton therapy (IMPT) versus intensity-modulated radiation therapy (IMRT) for the treatment of head and neck cancer: A dosimetric comparison
    Nguyen, My-Lien
    Cantrell, J. Nathan
    Ahmad, Salahuddin
    Henson, Christina
    MEDICAL DOSIMETRY, 2021, 46 (03) : 259 - 263
  • [48] Planning and delivery of intensity-modulated radiation therapy
    Yu, Cedric X.
    Amies, Christopher J.
    Svatos, Michelle
    MEDICAL PHYSICS, 2008, 35 (12) : 5233 - 5241
  • [49] Phase I Study of Capecitabine, Carboplatin and Intensity-modulated Radiation Therapy for Head and Neck Cancer
    Thomas, Christopher Y.
    Read, Paul
    Petroni, Gina
    Reibel, James
    Levine, Paul A.
    ANTICANCER RESEARCH, 2009, 29 (07) : 2869 - 2876
  • [50] Posttreatment Quality-of-Life Assessment in Patients With Head and Neck Cancer Treated With Intensity-modulated Radiation Therapy
    O'Neill, Michael
    Heron, Dwight E.
    Flickinger, John C.
    Smith, Ryan
    Ferris, Robert L.
    Gibson, Michael
    AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 2011, 34 (05): : 478 - 482