Multi-defect detection based on ultrasonic Lamb wave sign phase coherence factor imaging method

被引:7
作者
Zhang, Meng-Ke [1 ]
Fan, Guo-Peng [1 ]
Zhu, Wen-Fa [1 ,2 ]
Zheng, Shu-Bin [1 ]
Chai, Xiao-Dong [1 ]
Wei-Lv [3 ]
Hui-Zhang [1 ]
机构
[1] Shanghai Univ Engn Sci, Sch Urban Rail Transportat, Shanghai 201620, Peoples R China
[2] East China Univ Sci & Technol, Sch Mech & Power Engn, Shanghai 200237, Peoples R China
[3] China Railway Sci & Ind Grp Co Ltd, Wuchang, Peoples R China
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
Lamb wave; sign coherence factor; ultrasonic phased array; imaging performance; TRANSMIT-RECEIVE ARRAY;
D O I
10.1784/insi.2021.63.11.659
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The ultrasonic Lamb wave total focusing method (TFM) only uses the amplitude of the defective scattered signal for virtual focused imaging, while ignoring the phase information of the scattered signal and the dispersion characteristics of the Lamb wave, resulting in low imaging resolution and easily produced artefacts in imaging. To solve this problem, an ultrasonic Lamb wave imaging method based on phase coherence is proposed in this paper and the sign coherence factor (SCF) in the full matrix scattering signal is extracted. Moreover, the method uses the SCF to weight the amplitude of the full matrix scattering signal, suppresses the side lobes of the defect echo signal and the Lamb wave dispersion effect, improves the ultrasonic Lamb wave imaging resolution and weakens the artefacts. Finally, single- and multiplehole defects in aluminium plates are detected for experimental validation using an ultrasonic phased array. The array performance indicator and signal-to-noise ratio are used as indicators for quantitative assessment of imaging performance. The results show that compared with the TFM imaging, the SCF imaging can effectively suppress the noise and scattered signal side lobes, improve the array performance indicator (API) by 69.1% and improve the signal-to-noise ratio (SNR) by 73.9%. In addition, the SCF imaging can effectively weaken the interference of scattered signals between multiple through-hole defects, resulting in fewer artefacts in imaging.
引用
收藏
页码:659 / 666
页数:8
相关论文
共 35 条
[1]   Eigenspace-Based Minimum Variance Beamforming Applied to Medical Ultrasound Imaging [J].
Asl, Babak Mohammadzadeh ;
Mahloojifar, Ali .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2010, 57 (11) :2381-2390
[2]   Synthetic Aperture Focusing for Short-Lag Spatial Coherence Imaging [J].
Bottenus, Nick ;
Byram, Brett C. ;
Dahl, Jeremy J. ;
Trahey, Gregg E. .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2013, 60 (09) :1816-1826
[3]   GRAIN NOISE REDUCTION BY PHASE COHERENCE IMAGING [J].
Camacho, J. ;
Brizuela, J. ;
Fritsch, C. .
REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 29A AND 29B, 2010, 1211 :855-862
[4]   Phase Coherence Imaging [J].
Camacho, Jorge ;
Parrilla, Montserrat ;
Fritsch, Carlos .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2009, 56 (05) :958-974
[5]  
Chai, 2021, IEEE SENS J, V21
[6]   Guided Wave Enhancement Phased Array Beamforming Scheme using Recursive Feedback [J].
Charutz, David M. ;
Mor, Etai ;
Harput, Sevan ;
Cowell, David M. J. ;
Smith, Peter R. ;
Freear, Steven .
2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2013, :166-169
[7]  
Chen Y, 2016, PROCEEDINGS OF 2016 IEEE FAR EAST FORUM ON NONDESTRUCTIVE EVALUATION/TESTING: NEW TECHNOLOGY & APPLICATION (IEEE FENDT 2016), P44, DOI 10.1109/FENDT.2016.7991992
[8]  
Davies J, 2007, AIP CONF PROC, V894, P681, DOI 10.1063/1.2718036
[9]  
Davies J, 2006, AIP CONF PROC, V820, P142
[10]   Needle Visibility for Deep Punctures with Curved Arrays [J].
Dencks, Stefanie ;
Susanti, Hesty ;
Schmitz, Georg .
2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, :1880-1883