Novel Crowbar System in Doubly Fed Induction Generators

被引:0
|
作者
Lafferte, Dario [1 ]
Dias, Milena [1 ]
Zacharias, Peter [1 ]
机构
[1] Univ Kassel, KDEE, Ctr Competence Distributed Power Technol, Kassel, Germany
关键词
Crowbar protection; doubly fed induction generator (DFIG); low voltage ride through (LVRT); wind power integration; WIND TURBINES;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Nowadays, grid code requirements demand that wind energy converters ( WEC) remain connected to the grid during grid faults and contribute to the voltage support, in the same way as conventional power plants. WEC which are capable of ridding through grid faults providing voltage and reactive power support are connected to the grid via electronic power converters, increasing the failure risk and reducing the reliability due to the negative influence of cosmic radiation on semiconductors. Doubly fed induction generators ( DFIG) are widely used for wind power generation, fulfil low voltage ride through ( LVRT) requirements and need a power converter for only 30% of the rated generator capacity, reducing the chip area and increasing the operation reliability. The crowbar protection is indispensable to avoid the disconnection of DFIG during grid faults and the damage of the rotor side converter. This work analyses the crowbar operation according to the grid code requirements and presents a novel crowbar system.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Experimental and Simulation Comparison for Timer Action Crowbar of Doubly-Fed Induction Generator
    Chen, WenJun
    Atkinson, David
    Chaal, Hamza
    Jovanovic, Milutin
    2011 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2011,
  • [42] An Adaptive Backstepping Controller of Doubly-Fed Induction Generators
    Tarek, Aounallah
    Abdelaziz, Hamzaoui
    Najib, Essounbouli
    Farid, Bouchafaa
    3RD INTERNATIONAL CONFERENCE ON CONTROL, ENGINEERING & INFORMATION TECHNOLOGY (CEIT 2015), 2015,
  • [43] Three-phase doubly fed induction generators: an overview
    Tazil, M.
    Kumar, V.
    Bansal, R. C.
    Kong, S.
    Dong, Z. Y.
    Freitas, W.
    IET ELECTRIC POWER APPLICATIONS, 2010, 4 (02) : 75 - 89
  • [44] Methodology for Smooth Connection of Doubly Fed Induction Generators to the Grid
    Tapia, Gerardo
    Santamaria, Giovanna
    Telleria, Mikel
    Susperregui, Ana
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2009, 24 (04) : 959 - 971
  • [45] Phase-amplitude model for doubly fed induction generators
    Huang, Hua
    Ju, Ping
    Pan, Xueping
    Jin, Yuqing
    Yuan, Xiaoming
    Gao, Yuan
    JOURNAL OF MODERN POWER SYSTEMS AND CLEAN ENERGY, 2019, 7 (02) : 369 - 379
  • [46] Enhanced Direct Power Control of Doubly Fed Induction Generators
    Rueckert, Bastian
    Hofmann, Wilfried
    PROCEEDINGS OF 14TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE (EPE-PEMC 2010), 2010,
  • [47] Online Parameter Identification Methods for Doubly Fed Induction Generators
    Thomsen, Soenke
    Rothenhagen, Kai
    Fuchs, Friedrich W.
    2008 IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-10, 2008, : 2735 - 2741
  • [48] Dynamic Programming Power Control for Doubly Fed Induction Generators
    Santos-Martin, David
    Rodriguez-Amenedo, Jose Luis
    Arnalte, Santiago
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2008, 23 (05) : 2337 - 2345
  • [49] Reactive Capability Limitations of Doubly-fed Induction Generators
    Singh, Bharat
    Singh, S. N.
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2009, 37 (04) : 427 - 440
  • [50] The Study on Grid Stability of Doubly Fed Induction Generators with Supercapacitors
    Guo, Chiyue
    Liu, Yili
    Ge, Junchen
    2024 4TH POWER SYSTEM AND GREEN ENERGY CONFERENCE, PSGEC 2024, 2024, : 127 - 131