Novel Crowbar System in Doubly Fed Induction Generators

被引:0
|
作者
Lafferte, Dario [1 ]
Dias, Milena [1 ]
Zacharias, Peter [1 ]
机构
[1] Univ Kassel, KDEE, Ctr Competence Distributed Power Technol, Kassel, Germany
关键词
Crowbar protection; doubly fed induction generator (DFIG); low voltage ride through (LVRT); wind power integration; WIND TURBINES;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Nowadays, grid code requirements demand that wind energy converters ( WEC) remain connected to the grid during grid faults and contribute to the voltage support, in the same way as conventional power plants. WEC which are capable of ridding through grid faults providing voltage and reactive power support are connected to the grid via electronic power converters, increasing the failure risk and reducing the reliability due to the negative influence of cosmic radiation on semiconductors. Doubly fed induction generators ( DFIG) are widely used for wind power generation, fulfil low voltage ride through ( LVRT) requirements and need a power converter for only 30% of the rated generator capacity, reducing the chip area and increasing the operation reliability. The crowbar protection is indispensable to avoid the disconnection of DFIG during grid faults and the damage of the rotor side converter. This work analyses the crowbar operation according to the grid code requirements and presents a novel crowbar system.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Research on influence of adaptive crowbar protection technology on doubly fed induction generator
    He, Chao
    Tan, Qinyue
    Yang, Liu
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2020, 41 (09): : 347 - 352
  • [22] Predictive Current Control of Doubly Fed Induction Generators
    Xu, Lie
    Zhi, Dawei
    Williams, Barry W.
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2009, 56 (10) : 4143 - 4153
  • [23] Optimal Intelligent Control for Doubly Fed Induction Generators
    Xia, Lingqin
    Chen, Guang
    Wu, Tao
    Gao, Yu
    Mohammadzadeh, Ardashir
    Ghaderpour, Ebrahim
    MATHEMATICS, 2023, 11 (01)
  • [24] Phase–amplitude model for doubly fed induction generators
    Hua HUANG
    Ping JU
    Xueping PAN
    Yuqing JIN
    Xiaoming YUAN
    Yuan GAO
    JournalofModernPowerSystemsandCleanEnergy, 2019, 7 (02) : 369 - 379
  • [25] Determination of Parameters of Doubly-Fed Induction Generators
    Dehnavifard, H.
    Wozniak, A. C.
    Khan, M. A.
    Barendse, P. S.
    2016 XXII INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES (ICEM), 2016, : 2769 - 2774
  • [26] Reduction of Bearing Currents in Doubly Fed Induction Generators
    Garcia, A. Munoz
    Holmes, D. G.
    Lipo, T. A.
    CONFERENCE RECORD OF THE 2006 IEEE INDUSTRY APPLICATIONS CONFERENCE, FORTY-FIRST IAS ANNUAL MEETING, VOL 1-5, 2006, : 84 - 89
  • [27] Analysis on Transient Equivalent Circuit of Doubly Fed Induction Generator with Crowbar Protection
    Tang, Cheng
    Lu, Yuping
    Huang, Tao
    PROCEEDINGS OF 2017 2ND INTERNATIONAL CONFERENCE ON POWER AND RENEWABLE ENERGY (ICPRE), 2017, : 208 - 213
  • [28] A Novel Rotor Current Controller Scheme for Grid Connected Doubly Fed Induction Generators
    Ozsoy, Esref Emre
    Sabanovic, Asif
    Golubovic, Edin
    Gokasan, Metin
    Bogosyan, Seta
    2014 16TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE AND EXPOSITION (PEMC), 2014, : 394 - 399
  • [29] Control system for unbalanced operation of stand-alone doubly fed induction generators
    Pena, Ruben
    Cardenas, Roberto
    Escobar, Enrique
    Clare, Jon
    Wheeler, Pat
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2007, 22 (02) : 544 - 545
  • [30] The impact of wind farms with doubly fed induction generators on power system electromechanical oscillations
    Jafarian, M.