Electrochemical determination of lead in human blood serum and urine by anodic stripping voltammetry using glassy carbon electrodes covered with Ag-Hg and Ag-Bi bimetallic nanoparticles

被引:19
作者
Valera, Danny [1 ]
Sanchez, Mireya [2 ]
Dominguez, Jose R. [1 ]
Alvarado, Jose [1 ]
Espinoza-Montero, Patricio J. [3 ,4 ]
Carrera, Patricio [5 ]
Bonilla, Pablo [6 ]
Manciati, Carla [4 ]
Gonzalez, Gema [7 ,8 ]
Fernandez, Lenys [1 ,2 ]
机构
[1] Univ Simon Bolivar, Dept Quim, Apartado 89000, Caracas, Venezuela
[2] Escuela Politec Nacl, Escuela Formac Tecnol, Apartado 17-01-2759, Quito, Ecuador
[3] Pontificia Univ Catolica Ecuador, Escuela Ciencias Quim, Ave 12 Octubre & Roca,Apartado 17-01-2184, Quito, Ecuador
[4] Escuela Politec Nacl, Dept Ingn Civil & Ambiental, Ctr Invest & Control Ambiental, Apartado 17-01-2759, Quito, Ecuador
[5] Hidroecuador, Apartado EC1701, Quito, Ecuador
[6] Univ Cent Ecuador, Fac Ciencias Quim, Apartado 170521, Quito, Ecuador
[7] Inst Venezolano Invest Cient, Ctr Ingn Mat & Nanotecnol, San Antonio Los Altos, Venezuela
[8] Yachay Tech Univ, Sch Phys & Nanotechnol, Urcuqui, Ecuador
关键词
MERCURY FILM ELECTRODES; CADMIUM; SILVER; MICROELECTRODES; SPECIATION; SURFACE; SYSTEM; COPPER;
D O I
10.1039/c8ay01314d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The evaluation and application of glassy carbon electrodes modified with bimetallic nanoparticle deposits of Ag-Hg and Ag-Bi for determination of Pb(ii) is described. Deposition of the nanostructured bimetallic combinations on top of the glassy carbon (GC) substrate, previously covered with a Nafion (Nf) film, resulted in electrodes with substantially enlarged hydrogen evolution over-voltage. As indicated by scanning electron microscopy and atomic force microscopy images, most of the deposited nanoparticles, with an average size of 150 nm, were uniformly dispersed inside the Nafion net while a smaller amount remained on top of the embedded ones. Sensitivity tests of the AgBiNpNf/GC modified electrode produced a detection limit (DL), based on the 3s criterion, of 0.66 g L-1 and 0.24 g L-1 for the AgHgNpNf/GC electrode. Accuracy was assessed by comparison with quantification of Pb(ii) in human blood serum and urine samples analyzed by atomic absorption spectrometry, using a continuous source high resolution atomic absorption spectrometer.
引用
收藏
页码:4114 / 4121
页数:9
相关论文
共 36 条
[1]  
Baldo MA, 1997, ANALYST, V122, P1, DOI 10.1039/a605370j
[2]   Effect of Bi(III) concentration on the stripping voltammetric response of in situ bismuth-coated carbon paste and gold electrodes [J].
Baldrianova, L. ;
Svancara, I. ;
Vlcek, M. ;
Economou, A. ;
Sotiropoulos, S. .
ELECTROCHIMICA ACTA, 2006, 52 (02) :481-490
[3]   Poly(ester sulphonic acid) coated mercury thin film electrodes: characterization and application in batch injection analysis stripping voltammetry of heavy metal ions [J].
Brett, CMA ;
Fungaro, DA .
TALANTA, 2000, 50 (06) :1223-1231
[4]   Trace level voltammetric determination of lead and cadmium in sediment pore water by a bismuth-oxychloride particle-multiwalled carbon nanotube composite modified glassy carbon electrode [J].
Cerovac, Sandra ;
Guzsvany, Valeria ;
Konya, Zoltan ;
Ashrafi, Amir M. ;
Svancara, Ivan ;
Roncevic, Srdan ;
Kukovecz, Akos ;
Dalmacija, Bozo ;
Vytras, Karel .
TALANTA, 2015, 134 :640-649
[5]   A voltammetric sensor based on the glassy carbon electrode modified with multi-walled carbon nanotube/poly(pyrocatechol violet)/bismuth film for determination of cadmium and lead as environmental pollutants [J].
Chamjangali, M. Arab ;
Kouhestani, H. ;
Masdarolomoor, F. ;
Daneshinejad, H. .
SENSORS AND ACTUATORS B-CHEMICAL, 2015, 216 :384-393
[6]  
Christensen MK, 2000, ELECTROANAL, V12, P35, DOI 10.1002/(SICI)1521-4109(20000101)12:1<35::AID-ELAN35>3.0.CO
[7]  
2-0
[8]   Mercury film electrodes coated with negatively charged polymer films in speciation studies of trace amounts of lead [J].
Dam, MER ;
Schroder, KH .
ELECTROANALYSIS, 1996, 8 (11) :1040-1050
[9]   A POTENTIOSTATIC STUDY OF THE ELECTROLYTIC FORMATION OF AGO [J].
DIRKSE, TP .
ELECTROCHIMICA ACTA, 1990, 35 (09) :1445-1449
[10]  
Hao C., 2016, ACTA, V183, P1823