An Integrated Sensor-Model Approach for Haptic Feedback of Flexible Endoscopic Robots

被引:24
作者
Lai, Wenjie [1 ]
Cao, Lin [1 ]
Tan, Rex Xiao [2 ]
Tan, Yung Chuen [3 ]
Li, Xiaoguo [1 ]
Phuoc Thien Phan [1 ]
Tiong, Anthony Meng Huat [1 ]
Tjin, Swee Chuan [2 ]
Phee, Soo Jay [1 ]
机构
[1] Nanyang Technol Univ, Robot Res Ctr, Sch Mech & Aerosp Engn, Singapore, Singapore
[2] Nanyang Technol Univ, Sch Elect & Elect Engn, Photon Inst, Singapore, Singapore
[3] Nanyang Technol Univ, Temasek Labs, Singapore, Singapore
基金
新加坡国家研究基金会;
关键词
Flexible endoscopic surgical robots; Haptic force sensor; Fiber Bragg grating; Optical sensors; Tendon-sheath mechanism modeling; FORCE; PALPATION;
D O I
10.1007/s10439-019-02352-8
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Haptic feedback for flexible endoscopic surgical robots is challenging due to space constraints for sensors and shape-dependent force hysteresis of tendon-sheath mechanisms (TSMs). This paper proposes (1) a single-axis fiber Bragg grating (FBG)-based force sensor for a TSM of a robotic arm and (2) an integrated sensor-model approach to estimate forces on other TSMs of that arm. With a robust and simple structure, a temperature-compensated sensor can be mounted on the distal sheath to measure forces applied by the TSM. This proposed sensor was integrated with a empty set4.2 mm articulated robotic arm driven by six TSMs, with a measurement error of 0.37 N in this work. The measurement from the single sensor was used to identify parameters in the force-transmission models of all other TSMs in the robot, realizing a one-sensor-for-all-distal-forces measurement method. The sensor-model approach could accurately estimate the distal force with an RMSE of 0.65 N. An animal study was carried out to demonstrate the sensor's feasibility in real-life surgery. The sensor-model approach presented a robust, space-saving, and cost-effective solution for haptic feedback of endoscopic robots without any assumption on the shapes of the robot.
引用
收藏
页码:342 / 356
页数:15
相关论文
共 27 条
  • [21] Ren F., 2018, IEEE Photonics Journal, V10, P1
  • [22] Srivastava A., 2016, 2016 IEEE INT C ADV
  • [23] An MRI-Guided Telesurgery System Using a Fabry-Perot Interferometry Force Sensor and a Pneumatic Haptic Device
    Su, Hao
    Shang, Weijian
    Li, Gang
    Patel, Niravkumar
    Fischer, Gregory S.
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 2017, 45 (08) : 1917 - 1928
  • [24] Elongation Modeling and Compensation for the Flexible Tendon-Sheath System
    Sun, Zhenglong
    Wang, Zheng
    Phee, Soo Jay
    [J]. IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2014, 19 (04) : 1243 - 1250
  • [25] The benefit of force feedback in surgery: Examination of blunt dissection
    Wagner, Christopher R.
    Stylopoulos, Nicholas
    Jackson, Patrick G.
    Howe, Robert D.
    [J]. PRESENCE-VIRTUAL AND AUGMENTED REALITY, 2007, 16 (03): : 252 - 262
  • [26] Development of a 2-DOF Sensorized Surgical Grasper for Grasping and Axial Force Measurements
    Zarrin, Pouya Soltani
    Escoto, Abelardo
    Xu, Ran
    Patel, Rajni V.
    Naish, Michael D.
    Trejos, Ana Luisa
    [J]. IEEE SENSORS JOURNAL, 2018, 18 (07) : 2816 - 2826
  • [27] Zhou Z., 2005, FUND PROBL OPT MICR