Comparison of optical low coherence reflectometry and ultrasound pachymetry in the measurement of central corneal thickness before and after photorefractive keratectomy

被引:17
作者
Spadea, Leopoldo [1 ]
Giammaria, Daniele [1 ]
Di Genova, Lucia [1 ]
Fiasca, Arianna [1 ]
机构
[1] Univ Aquila, I-67100 Laquila, Italy
关键词
D O I
10.3928/1081-597X-20070901-04
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare an ultrasound pachymeter with an optical low coherence reflectometry (OLCR) pachymeter for measuring pre- and postoperative central corneal thickness of patients undergoing photorefractive keratectomy (PRK). METHODS: In a prospective, noncomparative, interventional study, 48 myopic eyes (mean manifest refractive spherical equivalent: -4.93 +/- 2.93 diopters [D]) of 30 healthy patients underwent PRK Pre- and postoperative central corneal thickness was measured by two examiners (El, E2) with an ultrasound pachymeter and an OLCR pachymeter. Agreement and inter-rater repeatability were determined using the comparison method described by Bland and Altman. RESULTS: The limits of agreement between the two devices ranged from 17.8 mu m (E1) to 20.5 mu m (E2) preoperatively and from 22.4 mu m (E1) to 16.9 mu m (E2) postoperatively. The coefficient of inter-rater repeatability ranged from 9.1 mu m (ultrasound pachymeter) to 5.4 mu m (OLCR pachymeter) preoperatively and from 7.1 mu m (ultrasound pachymeter) to 4.7 mu m (OLCR pachymeter) postoperatively. CONCLUSIONS: The OLCR pachymeter seems to show better pre- and postoperative repeatability compared to the ultrasound pachymeter. The agreement between the two devices should be considered acceptable for clinical practice. Photorefractive keratectomy did not affect the postoperative agreement and repeatability of the pachymeters.
引用
收藏
页码:661 / 666
页数:6
相关论文
共 19 条
[1]   Evaluating central corneal thickness measurements with noncontact optical low-coherence reflectometry and contact ultrasound pachymetry [J].
Airiani, Suzanna ;
Trokel, Stephen L. ;
Lee, Shing M. ;
Braunstein, Richard E. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 142 (01) :164-165
[2]  
Avitabile T, 1997, CORNEA, V16, P639
[3]   Central corneal thickness measurement with the Pentacam Scheimpflug system, optical low-coherence reflectometry pachymeter, and ultrasound pachymetry [J].
Barkana, Y ;
Gerber, Y ;
Elbaz, U ;
Schwartz, S ;
Ken-Dror, G ;
Avni, I ;
Zadok, D .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (09) :1729-1735
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]  
Bohnke M, 1998, J REFRACT SURG, V14, P140
[6]  
Bovelle R, 1999, ARCH OPHTHALMOL-CHIC, V117, P868
[7]   Comparison of corneal thickness measurements using ultrasound and Orbscan slit-scanning topography in normal and post-LASIK eyes [J].
Chakrabarti, HS ;
Craig, JP ;
Brahma, A ;
Malik, TY ;
McGhee, CNJ .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (11) :1823-1828
[8]  
Drexler W, 1997, INVEST OPHTH VIS SCI, V38, P1304
[9]   MEASUREMENT OF THE THICKNESS OF FUNDUS LAYERS BY PARTIAL COHERENCE TOMOGRAPHY [J].
DREXLER, W ;
HITZENBERGER, CK ;
SATTMANN, H ;
FERCHER, AF .
OPTICAL ENGINEERING, 1995, 34 (03) :701-710
[10]   Comparison of corneal pachymetry using ultrasound and Orbscan II [J].
Fakhry, MA ;
Artola, A ;
Belda, JL ;
Ayala, MJ ;
Alió, JL .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (02) :248-252