A novel vapor-generation technique is described for iodine determination in aqueous solutions. The iodide and iodate in the solution are converted to volatile iodine vapor through solution cathode glow discharge induced advanced redox processes. It is achieved by in situ produced highly reactive chemical species in the discharge, thereby eliminating the need for externally supplied sources of any redox reagents. Iodine vapor is readily generated from a background electrolyte containing 0.01 mol L-1 HNO3. The generated iodine vapor is then transported to inductively coupled plasma for determination by optical emission spectrometry. The influences of the background electrolyte, pH, discharge voltage, carrier gas flow rate and ICP power were examined. The detection limits of plasma induced vapor generation for KI and KIO3 were 0.30 and 0.43 mu g L-1, respectively. The repeatability, expressed as the relative standard deviation (n = 11) of a 0.05 mg L-1 standard, was 1.2% for KI and 1.9% for KIO3. Compared with conventional vapor generation technology, it offers several advantages. First, it eliminates the need for redox regents, and thus minimizes a source of contamination as well as hazards. Second, it is applicable to both iodide and iodate determination. In addition to iodide, iodate could also be directly converted to volatile iodine vapor without prior reduction. The method is sensitive and simple in operation, and requires no auxiliary reagents, served as a useful alternative to conventional vapor generation for trace iodine determination.
引用
收藏
页码:1390 / 1394
页数:5
相关论文
共 50 条
  • [1] Improved determination of iodine by sequential (photo)chemical vapor generation and pneumatic nebulization in the programmable temperature spray chamber and inductively coupled plasma optical emission spectrometry
    Jankowski, K.
    Giersz, J.
    Paprocka, M.
    MICROCHEMICAL JOURNAL, 2014, 113 : 17 - 22
  • [2] Flow Injection Photochemical Vapor Generation Coupled with Miniaturized Solution-Cathode Glow Discharge Atomic Emission Spectrometry for Determination and Speciation Analysis of Mercury
    Mo, Jiamei
    Li, Qing
    Guo, Xiaohong
    Zhang, Guoxia
    Wang, Zheng
    ANALYTICAL CHEMISTRY, 2017, 89 (19) : 10353 - 10360
  • [3] Determination of inorganic mercury in petroleum production water by inductively coupled plasma optical emission spectrometry following photochemical vapor generation
    Francisco, Barbara Bruna A.
    Rocha, Anderson A.
    Grinberg, Patricia
    Sturgeon, Ralph E.
    Cassella, Ricardo J.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2016, 31 (03) : 751 - 758
  • [4] REVIEW: Iodine Determination by Inductively Coupled Plasma Spectrometry
    Oliveira, Adriana A.
    Trevizan, Lilian C.
    Nobrega, Joaquim A.
    APPLIED SPECTROSCOPY REVIEWS, 2010, 45 (06) : 447 - 473
  • [5] Ultra-sensitive determination of inorganic arsenic valence by solution cathode glow discharge-atomic emission spectrometry coupled with hydride generation
    Guo, Xiaohong
    Peng, Xiaoxu
    Li, Qing
    Mo, Jiamei
    Du, Yiping
    Wang, Zheng
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2017, 32 (12) : 2416 - 2422
  • [6] Use of oxidation and reduction vapor generation for lowering the detection limits of iodine in biological samples by inductively coupled plasma atomic emission spectrometry
    Vtorushina, E. A.
    Saprykin, A. I.
    Knapp, G.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2009, 64 (02) : 129 - 135
  • [7] High-efficiency photooxidation vapor generation of osmium for determination by inductively coupled plasma-optical emission spectrometry
    Zhu, Zhenli
    He, Dong
    Huang, Chunying
    Zheng, Hongtao
    Zhang, Suicheng
    Hu, Shenghong
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2014, 29 (03) : 506 - 511
  • [8] In situ vapor generation inductively coupled plasma spectrometry for determination of iodine using a triple-mode microflow ultrasonic nebulizer after alkaline solubilization
    Matusiewicz, Henryk
    Slachcinski, Mariusz
    ANALYTICAL METHODS, 2010, 2 (10) : 1592 - 1598
  • [9] Determination of iodine in polyamide by inductively-coupled plasma/mass spectrometry
    Devouge-Boyer, Christine
    Mouda, Sarah
    Gueguen, Olivier
    Marcotte, Stephane
    TALANTA, 2018, 189 : 568 - 572
  • [10] Determination of iodine and bromine in coal and atmospheric particles by inductively coupled plasma mass spectrometry
    Sun, Mingxing
    Gao, Yunchuan
    Wei, Biwen
    Wu, Xiaowei
    TALANTA, 2010, 81 (1-2) : 473 - 476