Functional MRI using sensitivity-encoded echo planar imaging (SENSE-EPI)

被引:90
作者
Preibisch, C
Pilatus, U
Bunke, R
Hoogenraad, F
Zanella, F
Lanfermann, H
机构
[1] Univ Frankfurt, Dept Neuroradiol, D-60528 Frankfurt, Germany
[2] Philips Med Syst, Hamburg, Germany
[3] Philips Med Syst, Best, Netherlands
关键词
D O I
10.1016/S1053-8119(03)00080-6
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Parallel imaging methods become increasingly available on clinical MR scanners. To investigate the potential of sensitivity-encoded single-shot EPI (SENSE-EPI) for functional MRI, five imaging protocols at different SENSE reduction factors (R) and matrix sizes were compared with respect to their noise characteristics and their sensitivity toward functional activation in a motor task examination. At constant echo times, SENSE-EPI was either used to shorten the single volume acquisition times (TRmin) at matrix size 128 x 100 (22 slices) from 3.9 s (no SENSE) to 2.0 s at R = 3, or to increase the matrix size to 192 x 153 (22 slices), resulting in TRmin = 5.3 s for R = 2 or TRmin = 3.4 s for R = 3. At the lower resolution, the bisection of echo train length (R = 2) substantially reduced distortions and blurring, while signal-to-noise and statistical power (measured by cluster size and maximum t value per unit time) were hardly reduced. At R = 3 the additional gain in speed and distortion reduction was quite small, while signal-to-noise and statistical power dropped significantly. With enhanced spatial resolution the time course signal-to-noise was better than expected from theory for purely thermal noise because of a reduced contribution of physiological noise, and statistical power almost reached that of the regular, low-resolution single-shot EPI, with a slight drop off toward R = 3. Thus, SENSE-EPI allows to substantially increase speed and spatial resolution in fMRI. At SENSE reduction factors up to R = 2, the potential drawbacks regarding signal-to-noise and statistical power are almost negligible. (C) 2003 Elsevier Science (USA). All rights reserved.
引用
收藏
页码:412 / 421
页数:10
相关论文
共 69 条
[1]  
[Anonymous], 1998, ECHO PLANAR IMAGING
[2]  
[Anonymous], 1998, Echo-Planar Imaging: Theory, Technique and Application, DOI DOI 10.1177/004057368303900411
[3]  
Ashburner J, 1999, HUM BRAIN MAPP, V7, P254, DOI 10.1002/(SICI)1097-0193(1999)7:4<254::AID-HBM4>3.0.CO
[4]  
2-G
[5]   Improved diffusion-weighted single-shot echo-planar imaging (EPI) in stroke using Sensitivity Encoding (SENSE) [J].
Bammer, R ;
Keeling, SL ;
Augustin, M ;
Pruessmann, KP ;
Wolf, R ;
Stollberger, R ;
Hartung, HP ;
Fazekas, F .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (03) :548-554
[6]   FUNCTIONAL CONNECTIVITY IN THE MOTOR CORTEX OF RESTING HUMAN BRAIN USING ECHO-PLANAR MRI [J].
BISWAL, B ;
YETKIN, FZ ;
HAUGHTON, VM ;
HYDE, JS .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (04) :537-541
[7]   Reduction of physiological fluctuations in fMRI using digital filters [J].
Biswal, B ;
DeYoe, EA ;
Hyde, JS .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (01) :107-113
[8]   DYNAMIC MAPPING OF THE HUMAN VISUAL-CORTEX BY HIGH-SPEED MAGNETIC-RESONANCE-IMAGING [J].
BLAMIRE, AM ;
OGAWA, S ;
UGURBIL, K ;
ROTHMAN, D ;
MCCARTHY, G ;
ELLERMANN, JM ;
HYDER, F ;
RATTNER, Z ;
SHULMAN, RG .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1992, 89 (22) :11069-11073
[9]   Ghost artifact reduction for echo planar imaging using image phase correction [J].
Buonocore, MH ;
Gao, LS .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (01) :89-100
[10]   Compensation of susceptibility-induced signal loss in echo-planar imaging for functional applications [J].
Cordes, D ;
Turski, PA ;
Sorenson, JA .
MAGNETIC RESONANCE IMAGING, 2000, 18 (09) :1055-1068