Seasonal Variation of Disinfection By-products in Drinking Water in Central Chile

被引:5
|
作者
Loyola-Sepulveda, Rodrigo [1 ]
Mudge, Stephen M. [2 ]
Bravo-Linares, Claudio [3 ]
机构
[1] Univ Concepcion, Dept Oceanog, Lab Oceanog Quim, Concepcion, Chile
[2] The Lenz, Exponent UK, Harrogate HG2 8RE, England
[3] Univ Austral Chile, Fac Ciencias, Inst Ciencias Quim, Valdivia, Chile
来源
WATER QUALITY EXPOSURE AND HEALTH | 2013年 / 5卷 / 01期
关键词
Disinfection by-products; Trihalomethanes; Dichloromethane; Drinking water; Residence time; Central Chile; ORGANIC-COMPOUNDS; TRIHALOMETHANES; EXPOSURE;
D O I
10.1007/s12403-012-0082-y
中图分类号
TV21 [水资源调查与水利规划];
学科分类号
081501 ;
摘要
The formation of trihalomethanes (THMs) during water disinfection is related to several parameters such as water temperature, free chlorine and availability of dissolved organic matter. This paper compares and quantifies the THMs in drinking water from Concepcion city in the Bio Bio Region of central Chile, during summer of 2007 and autumn-winter 2008. THM concentrations in the source water were low (0.001-0.023 mu g L-1). The concentration ranges in summer sampling period for the drinking water were 9.7-111.6, 0.1-1.0 and 0.9-25.5 mu g L-1 for chloroform (CHCl3), and dibromochloromethane (CHClBr2) and bromodichloromethane (CHCl2Br), respectively; and 5.4-182.0, 0.1-0.9, 0.9-35.2 mu g L-1 respectively for the autumn-winter sampling period. Bromoform was not detected in any sample. There were significant correlations between the THMs concentration and residence time of the water into the network, distance from the treatment plant and an inverse correlation to free chlorine and UV absorbance. In this system, temperature was not a major factor in the THM concentrations at the point of use although lower overall concentrations were measured in summer. The Additive Toxicity Index Value (0.07-1.4) for winter samples indicated that the Chilean Norm was exceeded at the more distant water utilisation points, where the residence time in the system was >600 minutes. This was not the case in summer as utilisation rates were greater reducing the residence times. Dichloromethane (DCM) was also detected at elevated concentrations in the water supply and exceeded the Chilean Norm (20 mu g L-1) at all points in the system, up to 12 times, and may pose more of a health risk than the THMs.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 50 条
  • [41] Reproductive and developmental effects of disinfection by-products in drinking water
    Reif, JS
    Hatch, MC
    Bracken, M
    Holmes, LB
    Schwetz, BA
    Singer, PC
    ENVIRONMENTAL HEALTH PERSPECTIVES, 1996, 104 (10) : 1056 - 1061
  • [42] The epidemiology and possible mechanisms of disinfection by-products in drinking water
    Nieuwenhuijsen, Mark J.
    Grellier, James
    Smith, Rachel
    Iszatt, Nina
    Bennett, James
    Best, Nicky
    Toledano, Mireille
    PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2009, 367 (1904): : 4043 - 4076
  • [43] The occurrence of disinfection by-products in the drinking water of Athens, Greece
    Spyros K. Golfinopoulos
    Anastasia D. Nikolaou
    Themistokles D. Lekkas
    Environmental Science and Pollution Research, 2003, 10 : 368 - 372
  • [44] Risk assessment on disinfection by-products of drinking water of different water sources and disinfection processes
    Wang, Wuyi
    Ye, Bixiong
    Yang, Linsheng
    Li, Yonghua
    Wang, Yonghua
    ENVIRONMENT INTERNATIONAL, 2007, 33 (02) : 219 - 225
  • [45] DISINFECTION OF DRINKING-WATER, DISINFECTION BY-PRODUCTS AND CANCER - WHAT ABOUT AUSTRALIA
    PILOTTO, LS
    AUSTRALIAN JOURNAL OF PUBLIC HEALTH, 1995, 19 (01): : 89 - 93
  • [46] By-products formation during drinking water disinfection: A tool to assess disinfection efficiency?
    Von Gunten, U
    Driedger, A
    Gallard, H
    Salhi, E
    WATER RESEARCH, 2001, 35 (08) : 2095 - 2099
  • [47] Variation of Disinfection By-products Formation Potential Species at Several Stages of Drinking Water Treatment Plants
    Zhang, Qiang
    Liu, Bin
    ENVIRONMENTAL BIOTECHNOLOGY AND MATERIALS ENGINEERING (2013), 2013, 777 : 337 - +
  • [48] Oxyhalide disinfection by-products in packaged drinking water and their associated risk
    Saradhi, I. V.
    Sharma, S.
    Prathibha, P.
    Pandit, G. G.
    CURRENT SCIENCE, 2015, 108 (01): : 80 - 85
  • [49] Drinking Water Disinfection By-products and Their Carcinogenicity; A Review of an Unseen Crisis
    Aslani, Hassan
    Hosseini, Mohammad-Salar
    Mohammadi, Sahar
    Naghavi-Behzad, Mohammad
    INTERNATIONAL JOURNAL OF CANCER MANAGEMENT, 2019, 12 (05)
  • [50] Socioeconomic status and exposure to disinfection by-products in drinking water in Spain
    Gemma Castaño-Vinyals
    Kenneth P Cantor
    Cristina M Villanueva
    Adonina Tardon
    Reina Garcia-Closas
    Consol Serra
    Alfredo Carrato
    Núria Malats
    Nathaniel Rothman
    Debra Silverman
    Manolis Kogevinas
    Environmental Health, 10