Capillary Electrophoresis-Mass Spectrometry with Multisegment Injection and In-Capillary Preconcentration for High-Throughput and Sensitive Determination of Therapeutic Decapeptide Triptorelin in Pharmaceutical and Biological Matrices

被引:10
|
作者
Piestansky, Juraj [1 ,2 ]
Cizmarova, Ivana [1 ]
Stefanik, Ondrej [1 ]
Matuskova, Michaela [1 ]
Horniakova, Andrea [1 ]
Majerova, Petra [2 ]
Mikus, Peter [1 ,3 ]
机构
[1] Comenius Univ, Fac Pharm, Dept Pharmaceut Anal & Nucl Pharm, Odbojarov 10, SK-83232 Bratislava, Slovakia
[2] Slovak Acad Sci, Inst Neuroimmunol, Dubravska Cesta 9, SK-84510 Bratislava, Slovakia
[3] Comenius Univ, Fac Pharm, Toxicol & Antidoping Ctr, Odbojarov 10, SK-83232 Bratislava, Slovakia
关键词
capillary electrophoresis; tandem mass spectrometry; triptorelin peptide drug; field-enhanced sample injection; multisegment injection; pharmaceutical and biological samples; SOLID-PHASE EXTRACTION; LIQUID-CHROMATOGRAPHY; PLASMA; PEPTIDES; TESTOSTERONE; QUANTITATION; VALIDATION; SEPARATION; BEHAVIOR; RELEASE;
D O I
10.3390/biomedicines9101488
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A capillary electrophoresis-tandem mass spectrometry method with a multisegment injection and an in-capillary field-enhanced sample stacking for determination of therapeutic peptide triptorelin in pharmaceutical and biological matrices was developed. The CE separation conditions were optimized in order to obtain maximal separation efficiency, analytical signal intensity and stability, and minimal adsorption of the analyzed peptide onto the capillary wall (1 M formic acid-HFo, pH 1.88). The implementation of the field-enhanced sample injection into CE improved the value of limit of detection 50 times while the multisegment injection increased the sample throughput three times in comparison to a conventional CE approach. The proposed method was characterized by favorable performance parameters, such as linearity (r(2) & GE; 0.99), limit of detection (5 ng mL(-1) in water matrix, 25 ng mL(-1) in plasma matrix), precision (relative standard deviation, 1.5-9.4% for intraday and 2.3-11.9% for interday reproducibility), or accuracy (relative errors in the range of 80-109%). The FDA-validated method was successfully applied to the analysis of triptorelin in the commercial drug Diphereline(R) 0.1 mg (powder for injection) and in spiked human plasma samples. Favorable performance parameters along with proven application potentialities indicate the usefulness of the proposed method for its routine use in drug quality control laboratories and for clinical analysis, such as determination of triptorelin levels in plasma (for pharmacokinetic study).
引用
收藏
页数:14
相关论文
共 23 条
  • [1] High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-capillary Electrophoresis Mass Spectrometry
    Shanmuganathan, Meera
    Macklai, Sabrina
    Cardenas, Clara Barrenas
    Kroezen, Zachary
    Kim, Marcus
    Zizek, William
    Lee, Howard
    Britz-McKibbin, Philip
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2019, (146):
  • [2] Robust Method for High-Throughput Screening of Fatty Acids by Multisegment Injection-Nonaqueous Capillary Electrophoresis-Mass Spectrometry with Stringent Quality Control
    Azab, Sandi
    Ly, Ritchie
    Britz-McKibbin, Philip
    ANALYTICAL CHEMISTRY, 2019, 91 (03) : 2329 - 2336
  • [3] Enhancing Proteomic Throughput in Capillary Electrophoresis-Mass Spectrometry by Sequential Sample Injection
    Faserl, Klaus
    Sarg, Bettina
    Sola, Laura
    Lindner, Herbert H.
    PROTEOMICS, 2017, 17 (22)
  • [4] High-throughput screening of salivary polyamine markers for discrimination of colorectal cancer by multisegment injection capillary electrophoresis tandem mass spectrometry
    Igarashi, Kaori
    Ota, Sana
    Kaneko, Miku
    Hirayama, Akiyoshi
    Enomoto, Masanobu
    Katumata, Kenji
    Sugimoto, Masahiro
    Soga, Tomoyoshi
    JOURNAL OF CHROMATOGRAPHY A, 2021, 1652
  • [5] 1 3High Throughput Screening Method for Systematic Surveillance of Drugs of Abuse by Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
    DiBattista, Alicia
    Rampersaud, Dianne
    Lee, Howard
    Kim, Marcus
    Britz-McKibbin, Philip
    ANALYTICAL CHEMISTRY, 2017, 89 (21) : 11853 - 11861
  • [6] High-throughput and high-sensitivity capillary electrophoresis-mass spectrometry method for sulfur-containing amino acids
    Zhao, Jieyu
    Dong, Bing
    Zhao, Yanni
    Yang, Jun
    Pei, Pei
    Ji, Xianbing
    Quan, Yulian
    JOURNAL OF ANALYTICAL SCIENCE AND TECHNOLOGY, 2021, 12 (01)
  • [7] A high-throughput liquid chromatography tandem mass spectrometry method for the comparative determination of fluticasone propionate by reversed-phase liquid chromatography and capillary electrophoresis methods in pharmaceutical nasal sprays
    Sangoi, Maximiliano da Silva
    Wrasse, Micheli
    D'Avila, Felipe Bianchini
    Bernardi, Raquel Martini
    de Oliveira, Paulo Renato
    Dalmora, Sergio Luiz
    Bueno Rolim, Clarice Madalena
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2009, 15 (06) : 723 - 730
  • [8] Direct automatic determination of biogenic amines in wine by flow injection-capillary electrophoresis-mass spectrometry
    Santos, B
    Simonet, BM
    Ríos, A
    Valcárcel, M
    ELECTROPHORESIS, 2004, 25 (20) : 3427 - 3433
  • [9] Determination of Mitragynine and 7-Hydroxymitragynine in Raw Kratom Plant Material by a Multisegment Injection Capillary Zone Electrophoresis-Tandem Mass Spectrometry
    Horniakova, Andrea
    Mikus, Peter
    Piestansky, Juraj
    JOURNAL OF SEPARATION SCIENCE, 2025, 48 (03)
  • [10] Rapid Screening of Urinary 1-Hydroxypyrene Glucuronide by Multisegment Injection-Capillary Electrophoresis-Tandem Mass Spectrometry: A High-Throughput Method for Biomonitoring of Recent Smoke Exposures
    Gill, Biban
    Jobst, Karl
    Britz-McKibbin, Philip
    ANALYTICAL CHEMISTRY, 2020, 92 (19) : 13558 - 13564