Hepatic pseudo-anisotropy: a specific artifact in hepatic diffusion-weighted images obtained with respiratory triggering

被引:48
作者
Nasu, Katsuhiro
Kuroki, Yoshifumi
Fujii, Hirofumi
Minami, Manabu
机构
[1] Univ Tsukuba, Sch Med, Dept Diagnost Radiol, Tsukuba, Ibaraki 3058575, Japan
[2] Tochigi Canc Ctr, Dept Radiol, Utsunomiya, Tochigi 3200834, Japan
[3] Natl Canc Ctr Hosp E, Dept Diagnost Radiol, Chiba 2778577, Japan
关键词
diffusion-weighted image; liver; pseudo-anisotropy; respiratory motion;
D O I
10.1007/s10334-007-0084-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Hepatic pseudo-anisotropy is an artifact observed in hepatic diffusion-weighted imaging under respiratory triggering (RT-DWI). To determine the clinical significance of this phenomenon, hepatic RT-DW images were reviewed. Methods: One hundred and five MR examinations, including RT-DWI, were assessed. The patient group included 62 non-cirrhotic and 43 cirrhotic individuals. All images were evaluated by mutual agreement of two radiologists from the viewpoints of incidence of pseudo-anisotropy and correlation between pseudo-anisotropy and the quality of trace images. The ADC of normal hepatic parenchyma of non-cirrhotic livers were measured in both areas with and without pseudoanisotropy. Results: Pseudo-anisotropy was observed in 60% of non-cirrhotic (37/62) and 30% of cirrhotic (13/43) images. The difference between the two groups was statistically significant (P < 0.001). The quality of trace images showed a tendency to worsen as pseudo-anisotropy became significant. However, the quality of trace images was generally satisfactory, with only two patients whose trace images were difficult to interpret due to pseudo-anisotropy. The areas with pseudo-anisotropy showed higher ADC than those without pseudo-anisotropy (P < 0.001). Conclusion: Pseudo-anisotropy is a type of artifact that originates from respiratory movement. Even though respiratory triggering is employed, ADC measurement of the liver is inaccurate because of pseudo-anisotropy, especially in noncirrhoticpatients.
引用
收藏
页码:205 / 211
页数:7
相关论文
共 25 条
[1]   Improved diffusion-weighted single-shot echo-planar imaging (EPI) in stroke using Sensitivity Encoding (SENSE) [J].
Bammer, R ;
Keeling, SL ;
Augustin, M ;
Pruessmann, KP ;
Wolf, R ;
Stollberger, R ;
Hartung, HP ;
Fazekas, F .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (03) :548-554
[2]  
Basser PJ, 2000, MAGNET RESON MED, V44, P625, DOI 10.1002/1522-2594(200010)44:4<625::AID-MRM17>3.0.CO
[3]  
2-O
[4]  
BENEVISTE H, 1992, STROKE, V23, P746
[5]   Surgical therapy for metastatic disease to the liver [J].
Bentrem, DJ ;
DeMatteo, RP ;
Blumgart, LH .
ANNUAL REVIEW OF MEDICINE, 2005, 56 :139-156
[6]   ANALYSIS OF ROTATION AND STRESS RATE IN DEFORMING BODIES [J].
DIENES, JK .
ACTA MECHANICA, 1979, 32 (04) :217-232
[7]   Lymphomas and high-grade astrocytomas: Comparison of water diffusibility and histologic characteristics [J].
Guo, AC ;
Cummings, TJ ;
Dash, RC ;
Provenzale, JM .
RADIOLOGY, 2002, 224 (01) :177-183
[8]  
Kuroki Yoshifumi, 2004, Magn Reson Med Sci, V3, P79, DOI 10.2463/mrms.3.79
[9]   Artifacts and pitfalls in diffusion MRI [J].
Le Bihan, Denis ;
Poupon, Cyril ;
Amadon, Alexis ;
Lethimonnier, Franck .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (03) :478-488
[10]  
MURZ P, 2002, RADIOLOGY, V224, P258