Hepatic pseudo-anisotropy: a specific artifact in hepatic diffusion-weighted images obtained with respiratory triggering

被引:48
作者
Nasu, Katsuhiro
Kuroki, Yoshifumi
Fujii, Hirofumi
Minami, Manabu
机构
[1] Univ Tsukuba, Sch Med, Dept Diagnost Radiol, Tsukuba, Ibaraki 3058575, Japan
[2] Tochigi Canc Ctr, Dept Radiol, Utsunomiya, Tochigi 3200834, Japan
[3] Natl Canc Ctr Hosp E, Dept Diagnost Radiol, Chiba 2778577, Japan
关键词
diffusion-weighted image; liver; pseudo-anisotropy; respiratory motion;
D O I
10.1007/s10334-007-0084-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Hepatic pseudo-anisotropy is an artifact observed in hepatic diffusion-weighted imaging under respiratory triggering (RT-DWI). To determine the clinical significance of this phenomenon, hepatic RT-DW images were reviewed. Methods: One hundred and five MR examinations, including RT-DWI, were assessed. The patient group included 62 non-cirrhotic and 43 cirrhotic individuals. All images were evaluated by mutual agreement of two radiologists from the viewpoints of incidence of pseudo-anisotropy and correlation between pseudo-anisotropy and the quality of trace images. The ADC of normal hepatic parenchyma of non-cirrhotic livers were measured in both areas with and without pseudoanisotropy. Results: Pseudo-anisotropy was observed in 60% of non-cirrhotic (37/62) and 30% of cirrhotic (13/43) images. The difference between the two groups was statistically significant (P < 0.001). The quality of trace images showed a tendency to worsen as pseudo-anisotropy became significant. However, the quality of trace images was generally satisfactory, with only two patients whose trace images were difficult to interpret due to pseudo-anisotropy. The areas with pseudo-anisotropy showed higher ADC than those without pseudo-anisotropy (P < 0.001). Conclusion: Pseudo-anisotropy is a type of artifact that originates from respiratory movement. Even though respiratory triggering is employed, ADC measurement of the liver is inaccurate because of pseudo-anisotropy, especially in noncirrhoticpatients.
引用
收藏
页码:205 / 211
页数:7
相关论文
共 25 条
  • [1] Improved diffusion-weighted single-shot echo-planar imaging (EPI) in stroke using Sensitivity Encoding (SENSE)
    Bammer, R
    Keeling, SL
    Augustin, M
    Pruessmann, KP
    Wolf, R
    Stollberger, R
    Hartung, HP
    Fazekas, F
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (03) : 548 - 554
  • [2] Basser PJ, 2000, MAGNET RESON MED, V44, P625, DOI 10.1002/1522-2594(200010)44:4<625::AID-MRM17>3.0.CO
  • [3] 2-O
  • [4] BENEVISTE H, 1992, STROKE, V23, P746
  • [5] Surgical therapy for metastatic disease to the liver
    Bentrem, DJ
    DeMatteo, RP
    Blumgart, LH
    [J]. ANNUAL REVIEW OF MEDICINE, 2005, 56 : 139 - 156
  • [6] ANALYSIS OF ROTATION AND STRESS RATE IN DEFORMING BODIES
    DIENES, JK
    [J]. ACTA MECHANICA, 1979, 32 (04) : 217 - 232
  • [7] Lymphomas and high-grade astrocytomas: Comparison of water diffusibility and histologic characteristics
    Guo, AC
    Cummings, TJ
    Dash, RC
    Provenzale, JM
    [J]. RADIOLOGY, 2002, 224 (01) : 177 - 183
  • [8] Kuroki Yoshifumi, 2004, Magn Reson Med Sci, V3, P79, DOI 10.2463/mrms.3.79
  • [9] Artifacts and pitfalls in diffusion MRI
    Le Bihan, Denis
    Poupon, Cyril
    Amadon, Alexis
    Lethimonnier, Franck
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (03) : 478 - 488
  • [10] MURZ P, 2002, RADIOLOGY, V224, P258