Experimental Validation of a Numerical Model of a Ventilated Facade with Horizontal and Vertical Open Joints

被引:18
|
作者
Sanchez, Maria Nuria [1 ]
Giancola, Emanuela [1 ]
Blanco, Eduardo [2 ]
Soutullo, Silvia [1 ]
Suarez, Maria Jose [2 ]
机构
[1] Ctr Invest Energet Medioambient & Tecnol, Dept Energy, Madrid 28040, Spain
[2] Univ Oviedo, EDZE Dept Energy, Gijon 33271, Asturias, Spain
关键词
building envelope; ventilated facades; natural convection; PIV; CFD simulation; experimental validation; DOUBLE-SKIN FACADE; BUILDING ENERGY PERFORMANCE; HEAT-TRANSFER; NATURAL-CONVECTION; THERMAL PERFORMANCE; CROSS-VENTILATION; CFD SIMULATION; AIR; FLOW; SYSTEM;
D O I
10.3390/en13010146
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Commercial and residential building is one of the four major final energy consumption and end-use sectors. In this sector, cooling loads represent an important part of the energy consumption, and therefore, they must be minimized, improving the energy efficiency of buildings. Ventilated facades are one of the most widely used passive elements that are integrated into buildings, precisely with the aim of reducing these loads. This reduction is due to the airflow induced in the air cavity by the buoyancy forces, when the solar radiation heats the outer layer of the facade. In the open joint ventilated facades (OJVF), ventilation is attained through the open joints between the panels composing the outer layer. Despite the steadily growing research in the characterization of this type of system, few studies combine the numerical modelling of OJVF with experimental results for the assessment of the airflow in the ventilated cavities. This paper experimentally validates a numerical simulation model of an OJVF. Firstly, the facade performance has been experimentally assessed in a laboratory model determining the temperatures in the panels and air gap and measuring the flow field at the gap using particle image velocimetry (PIV) techniques. Secondly, a numerical model has been developed using advanced Computational Fluid Dynamics (CFD) simulation tools. Finally, an experimental validation of the numerical model has been done. Experimental and numerical results are compared in different planes inside the ventilated cavity. The discrete ordinates (DO) radiation model and the k-epsilon renormalisation group (RNG) turbulence model better adjust the simulated results to the experimental ones.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Numerical Slug Flow Model of Curved Pipes with Experimental Validation
    Shi, Shuzhe
    Wu, Xiaodong
    Han, Guoqing
    Zhong, Ziyao
    Li, Zhun
    Sun, Ke
    ACS OMEGA, 2019, 4 (12): : 14831 - 14840
  • [42] Experimental and numerical investigation of smoke dynamics in vertical cylinders and open-air environment
    Ahn, Chan-Sol
    Park, Chan-Woo
    Kim, Min-Woo
    Kim, Tae-Gun
    James, Scott C.
    Yoon, Youngbin
    Yarin, Alexander L.
    Yoon, Sam S.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 135 : 985 - 995
  • [43] Optimum performance of a horizontal axis tidal current turbine: A numerical parametric study and experimental validation
    Alipour, Ramin
    Alipour, Roozbeh
    Fardian, Farhad
    Tahan, Mohammad Hossein
    ENERGY CONVERSION AND MANAGEMENT, 2022, 258
  • [44] Numerical Stimulation and Experimental Validation of Stress in C/SiC Riveted Joints under Shear Load
    Zhang Qing
    Liu Yongsheng
    Men Jing
    Wang Qing
    Cheng Laifei
    Zhang Litong
    RARE METAL MATERIALS AND ENGINEERING, 2014, 43 (02) : 327 - 330
  • [45] Experimental validation of a hybrid model for vertical ground heat exchangers under on-off operation conditions
    Maestre, Ismael R.
    Gonzalez Gallero, Francisco Javier
    Gomez, Pascual Alvarez
    Foncubierta Blazquez, Juan Luis
    ENERGY AND BUILDINGS, 2019, 204
  • [46] Compression strength of ventilated corrugated paperboard packages: Numerical modelling, experimental validation and effects of vent geometric design
    Fadiji, Tobi
    Coetzee, Corne
    Opara, Umezuruike Linus
    BIOSYSTEMS ENGINEERING, 2016, 151 : 231 - 247
  • [47] An experimental and numerical model of a desiccant facade. A case of study of an office building in different weather conditions
    Fernandez Hernandez, Francisco
    Jimenez Navarro, Juan Pablo
    Atienza-Marquez, Antonio
    Cejudo Lopez, Jose M.
    Carrillo Andres, Antonio
    ENERGY AND BUILDINGS, 2020, 224
  • [48] A Simplified Numerical Model for the Assessment of Vibration in Subway Lines with Experimental Validation
    dos Santos, Danilo Pereira
    Saleme Gidrao, Gustavo de Miranda
    Carrazedo, Ricardo
    INTERNATIONAL JOURNAL OF STRUCTURAL STABILITY AND DYNAMICS, 2021, 21 (11)
  • [49] Numerical model and experimental validation of heat storage with phase change materials
    Bony, Jacques
    Citherlet, Stephane
    ENERGY AND BUILDINGS, 2007, 39 (10) : 1065 - 1072
  • [50] A numerical model for electro-active polymer actuators with experimental validation
    Potter, Mark
    Gouder, Kevin
    Morrison, Jonathan F.
    SENSORS AND ACTUATORS A-PHYSICAL, 2011, 170 (1-2) : 121 - 130