Experimental Validation of a Numerical Model of a Ventilated Facade with Horizontal and Vertical Open Joints

被引:18
|
作者
Sanchez, Maria Nuria [1 ]
Giancola, Emanuela [1 ]
Blanco, Eduardo [2 ]
Soutullo, Silvia [1 ]
Suarez, Maria Jose [2 ]
机构
[1] Ctr Invest Energet Medioambient & Tecnol, Dept Energy, Madrid 28040, Spain
[2] Univ Oviedo, EDZE Dept Energy, Gijon 33271, Asturias, Spain
关键词
building envelope; ventilated facades; natural convection; PIV; CFD simulation; experimental validation; DOUBLE-SKIN FACADE; BUILDING ENERGY PERFORMANCE; HEAT-TRANSFER; NATURAL-CONVECTION; THERMAL PERFORMANCE; CROSS-VENTILATION; CFD SIMULATION; AIR; FLOW; SYSTEM;
D O I
10.3390/en13010146
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Commercial and residential building is one of the four major final energy consumption and end-use sectors. In this sector, cooling loads represent an important part of the energy consumption, and therefore, they must be minimized, improving the energy efficiency of buildings. Ventilated facades are one of the most widely used passive elements that are integrated into buildings, precisely with the aim of reducing these loads. This reduction is due to the airflow induced in the air cavity by the buoyancy forces, when the solar radiation heats the outer layer of the facade. In the open joint ventilated facades (OJVF), ventilation is attained through the open joints between the panels composing the outer layer. Despite the steadily growing research in the characterization of this type of system, few studies combine the numerical modelling of OJVF with experimental results for the assessment of the airflow in the ventilated cavities. This paper experimentally validates a numerical simulation model of an OJVF. Firstly, the facade performance has been experimentally assessed in a laboratory model determining the temperatures in the panels and air gap and measuring the flow field at the gap using particle image velocimetry (PIV) techniques. Secondly, a numerical model has been developed using advanced Computational Fluid Dynamics (CFD) simulation tools. Finally, an experimental validation of the numerical model has been done. Experimental and numerical results are compared in different planes inside the ventilated cavity. The discrete ordinates (DO) radiation model and the k-epsilon renormalisation group (RNG) turbulence model better adjust the simulated results to the experimental ones.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Energy evaluation of an horizontal open joint ventilated facade
    Jose Suarez, Maria
    Sanjuan, Cristina
    Jose Gutierrez, Antonio
    Pistono, Jorge
    Blanco, Eduardo
    APPLIED THERMAL ENGINEERING, 2012, 37 : 302 - 313
  • [2] Experimental evaluation of the airflow behaviour in horizontal and vertical Open Joint Ventilated Facades using Stereo-PIV
    Sanchez, M. N.
    Giancola, E.
    Suarez, M. J.
    Blanco, E.
    Heras, M. R.
    RENEWABLE ENERGY, 2017, 109 : 613 - 623
  • [3] Experimental analysis and model validation of an opaque ventilated facade
    Peci Lopez, F.
    Jensen, R. L.
    Heiselberg, P.
    de Adana Santiago, M. Ruiz
    BUILDING AND ENVIRONMENT, 2012, 56 : 265 - 275
  • [4] Development and experimental validation of a simulation model for open joint ventilated facades
    Sanjuan, Cristina
    Jose Suarez, Maria
    Blanco, Eduardo
    del Rosario Heras, Maria
    ENERGY AND BUILDINGS, 2011, 43 (12) : 3446 - 3456
  • [5] Experimental and numerical assessment of rainwater intrusion in ventilated facades with open joints
    Van Linden, Stephanie
    van den Bossche, Nathan
    JOURNAL OF BUILDING PHYSICS, 2025,
  • [6] Energy performance of a ventilated facade by simulation with experimental validation
    Aparicio-Fernandez, Carolina
    Vivancos, Jose-Luis
    Ferrer-Gisbert, Pablo
    Royo-Pastor, Rafael
    APPLIED THERMAL ENGINEERING, 2014, 66 (1-2) : 563 - 570
  • [7] On the performance of a vertical helical coil heat exchanger. Numerical model and experimental validation
    Fernandez-Seara, Jose
    Pineiro-Pontevedra, Carolina
    Alberto Dopazo, J.
    APPLIED THERMAL ENGINEERING, 2014, 62 (02) : 680 - 689
  • [8] Experimental and numerical analysis of a naturally ventilated double-skin facade
    Souza, L. C. O.
    Souza, H. A.
    Rodrigues, E. F.
    ENERGY AND BUILDINGS, 2018, 165 : 328 - 339
  • [9] Experimental validation of a EnergyPlus model: Application of a multi-storey naturally ventilated double skin facade
    Andelkovic, Aleksandar S.
    Mujan, Igor
    Dakic, Stojanka
    ENERGY AND BUILDINGS, 2016, 118 : 27 - 36
  • [10] Impact of direct solar irradiance on heat transfer behind an open-jointed ventilated cladding: Experimental and numerical investigations
    Labat, Matthieu
    Woloszyn, Monika
    Garnier, Geraldine
    Rusaouen, Gilles
    Roux, Jean Jacques