STUDY ON LISTMODE OSEM RECONSTRUCTION INCLUDING IMAGE-SPACE RESOLUTION RECOVERY TECHNIQUES FOR COMPTON CAMERA

被引:1
作者
Kim, S. M. [1 ,2 ]
Lee, J. S. [1 ,2 ]
Park, M. J. [1 ,3 ]
Seo, H. [4 ]
Kim, C. H. [4 ]
Lee, C. S. [5 ]
Lee, D. S. [1 ,2 ]
Lee, S-J [6 ]
机构
[1] Seoul Natl Univ, Coll Med, Dept Nucl Med, Seoul, South Korea
[2] Seoul Natl Univ, Coll Med, Interdisciplinary Programs Radiat Appl Life Sci, Seoul, South Korea
[3] Seoul Natl Univ, Coll Med, Interdisciplinary Programs Biomed Engn Major, Seoul, South Korea
[4] Hanyang Univ, Dept Nucl Engn, Seoul, South Korea
[5] Chung Ang Univ, Dept Phys, Seoul, South Korea
[6] Univ Paichai, Dept Elect Engn, Daejeon, South Korea
来源
2010 7TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO | 2010年
关键词
Compton camera; OSEM reconstruction; resolution recovery; detector response function; image-space convolution; EMISSION;
D O I
10.1109/ISBI.2010.5490056
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Although Compton camera may has a great potential as next generation imaging modality comparing to SPECT and PET, its fully three-dimensional image reconstruction requires the considerable computational burden and the spatial resolution is suffered from the various physical phenomena arising during detection process. In this study, we investigated the accelerated statistical image reconstruction in which system matrix included a resolution recovery (RR) technique. We considered 3D Gaussian resolution model for the integrated angular and geometric uncertainties. The angular uncertainty is closely related to the limited energy resolution of the Compton camera and Doppler broadening and the geometric uncertainty is due to the segmented detectors. For RR, the 3D Gaussian resolution model is incorporated into listmode OSEM (LMOSEM) using image-space convolution operation. We investigated two different RR approaches: one (denoted by LMOSEM-RRF) is when the convolution is only performed in forward projection step, and the other (denoted by LMOSEM-RRFB) is when it is performed in both forward and backward projection steps. The simulation results showed that both RR approaches gave an improvement on spatial resolution for the resolution-degraded data due to both angular and geometric uncertainties. Although LMOSEM-RRF provided better resolution than LMOSEM-RRFB, LMOSEM-RRFB could still useful for low counting statistics in measurement.
引用
收藏
页码:796 / 799
页数:4
相关论文
共 13 条
[1]   ACCELERATED IMAGE-RECONSTRUCTION USING ORDERED SUBSETS OF PROJECTION DATA [J].
HUDSON, HM ;
LARKIN, RS .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (04) :601-609
[2]   Two approaches to implementing projector-backprojector pairs for 3D reconstruction from Compton scattered data [J].
Kim, Soo Mee ;
Lee, Jae Sung ;
Lee, Mi No ;
Lee, Ju Hahn ;
Lee, Chun Sik ;
Kim, Chan-Hyeong ;
Lee, Dong Soo ;
Lee, Soo-Jin .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 571 (1-2) :255-258
[3]  
LANGE K, 1984, J COMPUT ASSIST TOMO, V8, P306
[4]   Experimental results from the C-SPRINT prototype Compton camera [J].
LeBlanc, JW ;
Clinthorne, NH ;
Hua, CH ;
Nygard, E ;
Rogers, WL ;
Wehe, DK ;
Weilhammer, P ;
Wilderman, SJ .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (03) :201-204
[5]  
LEBLANC JW, 1999, THESIS U MICHIGAN AN
[6]  
Motomura S, 2004, IEEE NUCL SCI CONF R, P2152
[7]   Angular uncertainties due to geometry and spatial resolution in compton cameras [J].
Ordonez, CE ;
Chang, W ;
Bolozdynya, A .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (04) :1142-1147
[8]   EM algorithm system modeling by image-space techniques for PET reconstruction [J].
Reader, AJ ;
Julyan, PJ ;
Williams, H ;
Hastings, DL ;
Zweit, J .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (05) :1392-1397
[9]  
Shepp L A, 1982, IEEE Trans Med Imaging, V1, P113, DOI 10.1109/TMI.1982.4307558