共 47 条
Optimization of process parameters for determination of trace Hazardous dyes from industrial wastewaters based on nanostructures materials under ultrasound energy
被引:122
作者:
Dil, Ebrahim Alipanahpour
[1
]
Ghaedi, Mehrorang
[1
]
Asfaram, Arash
[1
]
Mehrabi, Fatemeh
[2
]
Bazrafshan, Ali Akbar
[1
]
机构:
[1] Univ Yasuj, Chem Dept, Yasuj 7591435, Iran
[2] Islamic Azad Univ, Gachsaran Branch, Dept Chem, Gachsaran, Iran
关键词:
Ultrasound energy assisted;
Multi-responses optimization;
Ag-ZnO-NP-AC;
Determination of dyes;
Derivative spectrophotometry;
Experimental design;
LIQUID-LIQUID MICROEXTRACTION;
SOLID-PHASE EXTRACTION;
RESPONSE-SURFACE METHODOLOGY;
WATER SAMPLES;
ACTIVATED CARBON;
METHYL GREEN;
ASSISTED EXTRACTION;
EXPERIMENTAL-DESIGN;
MICROVOLUME SPECTROPHOTOMETRY;
DERIVATIVE SPECTROPHOTOMETRY;
D O I:
10.1016/j.ultsonch.2017.07.022
中图分类号:
O42 [声学];
学科分类号:
070206 ;
082403 ;
摘要:
In this study, ultrasound -assisted dispersive solid phase micro-extraction based on nanosorbent namely silver zinc oxide nanoparticles loaded on activated carbon (Ag-ZnO-NP-AC) combined with derivative spectrophotometry method for the simultaneous pre-concentration and determination of Methyl Green (MG) and Rose Bengal (RB) dyes in water and industrial wastewater. Characterized sorbent by field emission scanning electron microscopy (FESEM), energy-dispersive X-ray spectroscopy (EDX), particle-size distribution (PSD), Fourier transform infrared spectroscopy (MR), X-ray powder diffraction (XRD) and Transmission electron microscopy (TEM) analysis with superior adsorption capacity was applied in ultrasound assisted dispersive-solid-phase micro-extraction (UA-DSPME) methodology. pH, sorbent mass, ultrasonication time, and eluent volume influence and contribution on response correspond to simultaneous pre-concentration and determination of MG and RB were optimized by response surface methodology (RSM) and results were compared with the experimental values. Under the optimal conditions (UA-DSPME), the enrichment factors (EFs) were 93.89 and 97.33 for the MG and RB dyes, respectively. The limits of detection were 2.14 and 2.73 ng mL(-1) and the limit of quantification were 7.15 and 9.09 ng mL(-1) for MG and RB, respectively. The analytes can be determined over 10-2000 ng mL(-1) with recoveries between 90.8% to 97.7% and RSDs less than 3.6%. The developed method due to simplicity and rapidity is able successful for repeatable and accurate monitoring of under study analytes from complicated matrices.
引用
收藏
页码:238 / 248
页数:11
相关论文