Random squat/stand maneuvers: a novel approach for assessment of dynamic cerebral autoregulation?

被引:14
作者
Barnes, Sam C. [1 ]
Ball, Naomi [1 ]
Panerai, Ronney B. [1 ,2 ]
Robinson, Thompson G. [1 ,2 ]
Haunton, Victoria J. [1 ,2 ]
机构
[1] Univ Leicester, Dept Cardiovasc Sci, Rm 210,Robert Kilpatrick Clin Sci Bldg,POB 65, Leicester LE2 7LX, Leics, England
[2] Glenfield Hosp, Natl Inst Hlth Res, Biomed Res Unit Cardiovasc Sci, Clinical Sci Wing, Leicester, Leics, England
关键词
transcranial Doppler ultrasound; reproducibility; transfer function analysis; cerebral hemodynamics; cerebral blood flow velocity; ARTERIAL-BLOOD PRESSURE; SQUAT-STAND MANEUVERS; SPONTANEOUS FLUCTUATIONS; TRANSCRANIAL DOPPLER; POSTURAL CHANGE; FLOW; HUMANS; MECHANISMS; EXERCISE; REPRODUCIBILITY;
D O I
10.1152/japplphysiol.00316.2017
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Squat/stand maneuvers (SSM) have been used to assess dynamic cerebral autoregulation (dCA), but always at a fixed frequency (FF). This study aimed to assess the use of random-frequency (RF) SSMs as a stimulus for measuring dCA and determine the reproducibility of FF and RFSSMs. Twenty-nine healthy volunteers [19 male, mean age 23.0 (4.9) yr] completed the study; 11 returned for a repeat visit (median 45 days). Heart rate, beat-to-beat blood pressure, middle cerebral artery (MCA) blood flow velocity, end-tidal CO2, and angle of the squat movement were measured. Subjects underwent four recordings: 5 min sitting, 5 min standing, FFSSMs (0.05Hz), and RFSSMs. Subjects were asked to rate the degree of exertion experienced while performing these maneuvers. Twenty-nine subjects completed the protocol; nine data sets were deemed unsuitable for further analysis. Mean ARI of 6.21 (1.04) while standing was significantly greater than during the SSMs (P < 0.01), with mean (SD) ARI during the FF and RFSSMs being 5.16 (1.43) and 5.37 (1.21), respectively. However, no significant difference was found between the ARI estimates from the two SSMs (P = 0.856) or for each of the four recordings between the two visits (P = 0.645). RFSSMs were found to be significantly less tiring than FFSSMs (P < 0.01). In conclusion, RFSSMs are an effective and noninvasive method of assessing dCA. There is no difference in the ARI estimates in comparison with FFSSMs. Although FFSSMs have been well tolerated previously, RFSSMs are preferred by healthy subjects and thus may be better tolerated by a patient population in a clinical setting. NEW & NOTEWORTHY RFSSMs provided comparable estimates of autoregulatory indices to FFSSMs. Instead of point estimates at the driven frequency, RFSSMs generate a broader power spectrum of changes in arterial blood pressure and cerebral blood flow velocity, allowing direct comparison with spontaneous fluctuations through transfer function analysis. Moreover, random-frequency SSMs are preferred by participants. They are a novel tool by which larger blood pressure oscillations can be elicited for the reliable measurement of dynamic cerebral autoregulation.
引用
收藏
页码:558 / 566
页数:9
相关论文
共 41 条
[31]   INITIAL BLOOD-PRESSURE FALL ON STAND UP AND EXERCISE EXPLAINED BY CHANGES IN TOTAL PERIPHERAL RESISTANCE [J].
SPRANGERS, RLH ;
WESSELING, KH ;
IMHOLZ, ALT ;
IMHOLZ, BPM ;
WIELING, W .
JOURNAL OF APPLIED PHYSIOLOGY, 1991, 70 (02) :523-530
[32]   Cardiac output and blood pressure during active and passive standing [J].
Tanaka, H ;
Sjoberg, BJ ;
Thulesius, O .
CLINICAL PHYSIOLOGY, 1996, 16 (02) :157-170
[33]   COMPARISON OF STATIC AND DYNAMIC CEREBRAL AUTOREGULATION MEASUREMENTS [J].
TIECKS, FP ;
LAM, AM ;
AASLID, R ;
NEWELL, DW .
STROKE, 1995, 26 (06) :1014-1019
[34]   Assessment of cerebral autoregulation: the quandary of quantification [J].
Tzeng, Y. C. ;
Ainslie, P. N. ;
Cooke, W. H. ;
Peebles, K. C. ;
Willie, C. K. ;
MacRae, B. A. ;
Smirl, J. D. ;
Horsman, H. M. ;
Rickards, C. A. .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2012, 303 (06) :H658-H671
[35]   Blood pressure regulation IX: cerebral autoregulation under blood pressure challenges [J].
Tzeng, Yu-Chieh ;
Ainslie, Philip N. .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2014, 114 (03) :545-559
[36]   Circulatory response evoked by a 3 s bout of dynamic leg exercise in humans [J].
Wieling, W ;
Harms, MPM ;
tenHarkel, ADJ ;
vanLieshout, JJ ;
Sprangers, RLH .
JOURNAL OF PHYSIOLOGY-LONDON, 1996, 494 (02) :601-611
[37]   Initial orthostatic hypotension: review of a forgotten condition [J].
Wieling, Wouter ;
Krediet, C. T. Paul ;
Van Dijk, Nynke ;
Linzer, Mark ;
Tschakovsky, Michael E. .
CLINICAL SCIENCE, 2007, 112 (3-4) :157-165
[38]  
WILKE JT, 1975, PHYSIOL PSYCHOL, V3, P345
[39]   Utility of transcranial Doppler ultrasound for the integrative assessment of cerebrovascular function [J].
Willie, C. K. ;
Colino, F. L. ;
Bailey, D. M. ;
Tzeng, Y. C. ;
Binsted, G. ;
Jones, L. W. ;
Haykowsky, M. J. ;
Bellapart, J. ;
Ogoh, S. ;
Smith, K. J. ;
Smirl, J. D. ;
Day, T. A. ;
Lucas, S. J. ;
Eller, L. K. ;
Ainslie, P. N. .
JOURNAL OF NEUROSCIENCE METHODS, 2011, 196 (02) :221-237
[40]   Transfer function analysis of dynamic cerebral autoregulation in humans [J].
Zhang, R ;
Zukerman, JH ;
Giller, CA ;
Levine, BD .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1998, 274 (01) :H233-H241