Upgraded bolometer system on JET for improved radiation measurements

被引:93
作者
Huber, A. [1 ]
McCormick, K.
Andrew, P.
Beaumont, P.
Dalley, S.
Fink, J.
Fuchs, J. C.
Fullard, K.
Fundamenski, W.
Ingessond, L. C.
Mast, F.
Jachmich, S.
Matthews, G. F.
Mertens, Ph.
Philipps, V.
Pitts, R. A.
Sanders, S.
Zeidner, W.
机构
[1] Forschungszentrum Julich, Inst Plasmaphys, EURATOM Assoc,Trilateral Euregio Cluster, D-52425 Julich, Germany
[2] Max Planck Inst Plasma Phys, EURATOM Assoc, D-85748 Garching, Germany
[3] UKAEA Euratom Fus Assoc, Culham Sci Ctr, Abingdon OX14 3DB, Oxon, England
[4] FOM, Inst Plasmafys, Nieuwegein, Netherlands
[5] Ecole Polytech Fed Lausanne, Assoc Euratom Confederat Suisse, CRPP, CH-1015 Lausanne, Switzerland
关键词
bolometry camera; JET; plasma; tomography;
D O I
10.1016/j.fusengdes.2007.03.027
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Two new main-vessel bolometric cameras (KB5) with horizontal and vertical views of the plasma cross-section have been installed on JET, providing a substantial upgrade in capabilities: more viewing chords (24 chords for each camera), higher energy range (up to 8 keV), higher sensitivity (similar to 6.2 V/W), lower noise and therefore, lower detectable signals (similar to 2 mu W/cm(2) at a bandwidth of 200 Hz), higher temporal resolution (similar to 2 ms). In addition, three new dedicated divertor bolometer cameras (KB3) with 12 lines-of-sight in total, optimised views and technical improvements have replaced the old ones. The combination of KB3 and KB5 systems provides measurements with significantly improved spatial resolution, allowing the divertor and main chamber radiation fractions to be clearly resolved. The sensitivity measured with an in situ electrical method matches very well with that obtained using a light source calibration. The deviation between the two methods is less than 7% and is in the range of the measurement accuracy. The experimentally measured geometric functions closely match those computed using the design values of geometry. Tomographic reconstructions of high density divertor plasmas with ITER-like configuration are presented which clearly demonstrate the capability of the new diagnostic. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:1327 / 1334
页数:8
相关论文
共 14 条
[1]   THE OPTICAL PROPERTIES OF EVAPORATED GOLD IN THE VACUUM ULTRAVIOLET FROM 300 A TO 2000 A [J].
CANFIELD, LR ;
HASS, G ;
HUNTER, WR .
JOURNAL DE PHYSIQUE, 1964, 25 (1-2) :124-129
[2]   Radiation distribution and energy balance during type-I ELMs in ASDEX Upgrade [J].
Fuchs, JC ;
Eich, T ;
Herrmann, A ;
Mast, KF .
JOURNAL OF NUCLEAR MATERIALS, 2005, 337 (1-3) :756-760
[3]  
FUCHS JC, 1998, EUR C ABSTR C, V22, P1510
[4]  
HAGEMANN HJ, 1974, SR747 DESY
[5]   Characterization of geometrical detection-system properties for two-dimensional tomography [J].
Ingesson, LC ;
Maggi, CF ;
Reichle, R .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (03) :1370-1378
[6]  
IPT-Albrecht GmbH, ING BUR PHYS TECHN
[7]   Integrated scenario in JET using real-time profile control [J].
Joffrin, E ;
Crisanti, F ;
Felton, R ;
Litaudon, X ;
Mazon, D ;
Moreau, D ;
Zabeo, L ;
Albanese, R ;
Ariola, M ;
Alves, D ;
Barana, O ;
Basiuk, V ;
Bécoulet, A ;
Bécoulet, M ;
Blum, J ;
Bolzonnella, T ;
Bosak, K ;
Chareau, JM ;
de Baar, M ;
de la Luna, E ;
de Vries, P ;
Dumortier, P ;
Elbeze, D ;
Farthing, J ;
Fernandes, H ;
Fenzi, C ;
Giannella, R ;
Guenther, K ;
Harling, J ;
Hawkes, N ;
Hender, TC ;
Howell, DF ;
Heesterman, P ;
Imbeaux, F ;
Innocente, P ;
Laborde, L ;
Lloyd, G ;
Lomas, PJ ;
McDonald, DC ;
Mailloux, J ;
Mantsinen, M ;
Messiaen, A ;
Murari, A ;
Ongena, J ;
Orsitto, F ;
Pericoli-Ridolfini, V ;
Riva, M ;
Sanchez, J ;
Sartori, F ;
Sauter, O .
PLASMA PHYSICS AND CONTROLLED FUSION, 2003, 45 :A367-A383
[8]   FAST BOLOMETRIC DIAGNOSTIC IN THE RFX REVERSED FIELD PINCH EXPERIMENT [J].
MAST, KF ;
GADANI, G ;
GAGGINI, P ;
GIUBBILEI, M ;
GUATIERI, R ;
MARTIN, P ;
MURARI, A ;
PARINI, A ;
PERDON, E .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (10) :4714-4716
[9]   A LOW-NOISE HIGHLY INTEGRATED BOLOMETER ARRAY FOR ABSOLUTE MEASUREMENT OF VUV AND SOFT X-RADIATION [J].
MAST, KF ;
VALLET, JC ;
ANDELFINGER, C ;
BETZLER, P ;
KRAUS, H ;
SCHRAMM, G .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1991, 62 (03) :744-750
[10]   New bolometry cameras for the JET enhanced performance phase [J].
McCormick, K ;
Huber, A ;
Ingesson, C ;
Mast, F ;
Fink, J ;
Zeidner, W ;
Guigon, A ;
Sanders, S .
FUSION ENGINEERING AND DESIGN, 2005, 74 (1-4) :679-683