Air-PCM heat exchanger for peak load management: Experimental and simulation

被引:80
作者
Stathopoulos, N. [1 ]
El Mankibi, M. [1 ]
Issoglio, R. [1 ]
Michel, P. [1 ]
Haghighat, F. [2 ]
机构
[1] ENTPE, Bldg & Civil Engn Lab LGCB, Lyon, France
[2] Concordia Univ, Dept Bldg Civil & Environm Engn, Montreal, PQ, Canada
关键词
Thermal storage; PCM; Heat exchanger; Peak load shifting; PHASE-CHANGE MATERIALS; SYSTEM; PERFORMANCE; BUILDINGS;
D O I
10.1016/j.solener.2016.03.030
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Peak power consumption is becoming an increasing problem worldwide and particularly in France during the late afternoon winter periods. This paper describes the experimental and numerical studies carried out to investigate the potential of a PCM (phase change material) - Air heat exchanger, conceived for load shifting purposes. The objective is to possess the necessary tools for the development of advanced control strategies taking into account various factors: peak power reduction, thermal comfort and indoor air quality. The experimental approach involved the construction of a heat exchanger coupled to an experimental cell. The heat storage system is composed of a set of PCM (paraffin) plates, embedded in the exchanger and integrated in a ventilation system. In parallel, a numerical model was developed using the apparent heat capacity approach and the finite differences method. Furthermore, a series of characterization tests was conducted and the experimental data were used for model calibration and validation. The model was then coupled with a building simulation program, presenting good agreement between the integrated model prediction and the experimental data. Finally, a preliminary control strategy of the test cell is presented along with results demonstrating the capabilities of such system for peak load management. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:453 / 466
页数:14
相关论文
共 24 条
[1]  
ADEME, STRAT UT RAT EN BAT
[2]   A comparison of heat transfer enhancement in a medium temperature thermal energy storage heat exchanger using fins [J].
Agyenim, Francis ;
Eames, Philip ;
Smyth, Mervyn .
SOLAR ENERGY, 2009, 83 (09) :1509-1520
[3]   Development of a model for compensating the influence of temperature gradients within the sample on DSC-results on phase change materials [J].
Albright, Greg ;
Farid, Mohammed ;
Al-Hallaj, Said .
JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2010, 101 (03) :1155-1160
[4]   Efficiency of free cooling using latent heat storage integrated into the ventilation system of a low energy building [J].
Arkar, C. ;
Vidrih, B. ;
Medved, S. .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2007, 30 (01) :134-143
[5]  
Baetens R., 2010, ENERGY BUILD, P1361
[6]   Numerical evaluation of a triple concentric-tube latent heat thermal energy storage [J].
Basal, Birol ;
Unal, Ahmet .
SOLAR ENERGY, 2013, 92 :196-205
[7]  
Bastani A., 2014, RENEW SUST ENERG REV, V10, P87
[8]   Characterization of melting and solidification in a real-scale PCM-air heat exchanger: Experimental results and empirical model [J].
Dolado, Pablo ;
Lazaro, Ana ;
Marin, Jose M. ;
Zalba, Belen .
RENEWABLE ENERGY, 2011, 36 (11) :2906-2917
[9]  
Dumortier D., 2003, THESIS
[10]   Prediction of hybrid ventilation performance using two simulation tools [J].
El Mankibi, M. ;
Cron, F. ;
Michel, P. ;
Inard, C. .
SOLAR ENERGY, 2006, 80 (08) :908-926