Corona inception field of typical overhead line conductors under variable atmospheric conditions

被引:28
作者
Bousiou, Evanthia, I [1 ]
Mikropoulos, Pantelis N. [1 ]
Zagkanas, Vasileios N. [2 ]
机构
[1] Aristotle Univ Thessaloniki, Fac Engn, Sch Elect & Comp Engn, High Voltage Lab, Thessaloniki 54124, Greece
[2] Fieldscale PC, 45 N Plastira, Thessaloniki 54250, Greece
关键词
Air density; Corona discharge; Humidity; Overhead lines; Stranded conductors; Transmission; POSITIVE DC CORONA; ONSET VOLTAGE; SURFACE CONDITIONS; NEGATIVE CORONA; ELECTRIC-FIELD; HVDC; POTENTIALS; CRITERION; GLAZE;
D O I
10.1016/j.epsr.2019.106032
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Corona inception field of line conductors is of major importance for assessing corona performance of overhead transmission lines. Using computational models that consider the ionization processes in corona discharge, the corona inception field of ACSR conductors typically utilized in overhead transmission lines is estimated. The interactive effects of line conductor geometry, voltage polarity as well as atmospheric conditions on corona inception field are assessed and discussed based on the ionization area around the conductor. It is shown that the corona inception field of bundle configurations can be satisfactorily approximated by that of the subconductor when considered single. Generally, the inception field of negative corona is slightly lower than that of positive corona and lesser affected by variations in atmospheric conditions. An empirical expression for the straight. forward estimation of the corona inception field of line conductors has been introduced, accounting well for the effects of conductor geometry, voltage polarity and atmospheric conditions.
引用
收藏
页数:10
相关论文
共 52 条
  • [1] Analysis of corona losses on monopolar dc transmission lines
    Abdel-Salam, M
    Mufti, A
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 1998, 44 (02) : 145 - 154
  • [2] AMORUSO V, 1991, EUR T ELECTR POW, V1, P15
  • [3] TRANSMISSION-LINES - EFFECT OF EARTH RESISTIVITY ON MAGNETIC-FIELD, IMAGES AND EQUIVALENT-CIRCUIT
    PERZ, MC
    RAGHUVEER, MR
    [J]. IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1979, 98 (06): : 2135 - 2143
  • [4] [Anonymous], 2017, B232B232M ASTM
  • [5] [Anonymous], 1966, 3601 CIGRE WG, V61
  • [6] Corona modeling in HVDC transmission lines based on a modified particle-in-cell approach
    Arruda, Carlos K. C.
    Lima, Antonio C. S.
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2015, 125 : 91 - 99
  • [7] Influence of Aged Conductor Surface Conditions on AC Corona Discharge With a Corona Cage
    Bian, Xingming
    Yu, Deming
    Chen, Lan
    MacAlpine, J. M. K.
    Wang, Liming
    Guan, Zhicheng
    Chen, Fangdong
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2011, 18 (03) : 809 - 818
  • [8] Bousiou E.I., 2017, 52 UPEC HER, P1, DOI [10.1109/UPEC.2017.8231874, DOI 10.1109/UPEC.2017.8231874]
  • [9] Bousiou E.I., 2016, 51 UPEC COIMBR, P1, DOI [10.1109/UPEC.2016.8114029, DOI 10.1109/UPEC.2016.8114029]
  • [10] Study on the Influence of Charged Glaze on the Corona Onset Voltage of Bundle conductor
    Chen, Ji
    Jiang, Xingliang
    Shu, Lichun
    Hu, Jianlin
    Hu, Qin
    Wang, Yaoxuan
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2014, 21 (04) : 1592 - 1599