Investigation of the advanced functionalities of a hybrid quadrupole orthogonal acceleration time-of-flight mass spectrometer

被引:19
|
作者
Weaver, Paul J. [1 ]
Laures, Alice M. -F. [1 ]
Wolff, Jean-Claude [1 ]
机构
[1] GlaxoSmithKline, Analyt Sci, Med Res Ctr, Stevenage SG1 2NY, Herts, England
关键词
D O I
10.1002/rcm.3052
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Time-of-flight mass spectrometry (ToF-MS) has gained wide acceptance in many fields of chemistry, proteomics, metabolomics and small molecule analysis. ToF-MS, however, has some inherent advantages and drawbacks. Numerous developments have been made to hybrid ToF instruments to improve their capabilities. We have used a quadrupole orthogonal acceleration ToF (Q-oa-ToF) instrument to assess developments made to improve resolution, dynamic range and signal-to-noise (S/N) ratios (i.e. sensitivity). Higher mass resolution can improve the analysis of mixtures containing compounds with similar m/z values and improved mass accuracy gives greater confidence for structural elucidation applications. Wide dynamic ranges are necessary for the analysis of unknown samples or samples that vary widely in analyte concentrations. The performance of the advanced functionalities for routine structural elucidation in terms of resolution, dynamic range and S/N ratios was investigated using test compounds. The results presented in this work demonstrate and validate the use of these new enhancements for Q-ToF instruments and also show their limitations. Copyright (0 2007 John Wiley & Sons, Ltd.
引用
收藏
页码:2415 / 2421
页数:7
相关论文
共 50 条
  • [41] Pseudorandom time-of-flight analysis with a time-of-flight mass spectrometer
    Bewig, L
    Buck, U
    Gandhi, SR
    Winter, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1996, 67 (02): : 417 - 422
  • [42] Dual linear ion trap/orthogonal acceleration time-of-flight mass spectrometer with improved precursor ion selectivity
    Hashimoto, Y
    Hasegawa, H
    Waki, I
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (11) : 1485 - 1491
  • [43] A 20 kV orthogonal acceleration time-of-flight mass spectrometer for matrix-assisted laser desorption/ionization
    Selby, DS
    Mlynski, V
    Guilhaus, M
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2001, 210 (1-3) : 89 - 100
  • [44] Application of the time-of-flight technique to pressure measurements in XHV by a quadrupole mass spectrometer
    Ogiwara, N
    Miyo, Y
    Ueda, Y
    VACUUM, 1996, 47 (6-8) : 575 - 578
  • [45] Implementation of ion/ion reactions in a quadrupole/time-of-flight tandem mass spectrometer
    Xia, Yu
    Chrisman, Paul A.
    Erickson, David E.
    Liu, Jian
    Liang, Xiaorong
    Londry, Frank A.
    Yang, Min J.
    McLuckey, Scott A.
    ANALYTICAL CHEMISTRY, 2006, 78 (12) : 4146 - 4154
  • [46] Quantitative proteomic analysis using a MALDI quadrupole time-of-flight mass spectrometer
    Griffin, TJ
    Gygi, SP
    Rist, B
    Aebersold, R
    Loboda, A
    Jilkine, A
    Ens, W
    Standing, KG
    ANALYTICAL CHEMISTRY, 2001, 73 (05) : 978 - 986
  • [47] Investigation of Isomeric Transformations of Chlorogenic Acid in Buffers and Biological Matrixes by Ultraperformance Liquid Chromatography Coupled with Hybrid Quadrupole/Ion Mobility/Orthogonal Acceleration Time-of-Flight Mass Spectrometry
    Xie, Cen
    Yu, Kate
    Zhong, Dafang
    Yuan, Tao
    Ye, Fei
    Jarrell, Joseph Andy
    Millar, Alan
    Chen, Xiaoyan
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2011, 59 (20) : 11078 - 11087
  • [48] BENDIX TIME-OF-FLIGHT MASS SPECTROMETER
    WILEY, WC
    SCIENCE, 1956, 124 (3226) : 817 - 820
  • [49] Miniature time-of-flight mass spectrometer
    McLoughlin, MP
    Anderson, CW
    Bryden, WA
    Carlson, MA
    Ecelberger, SA
    Ko, HW
    BIOMEDICAL SENSING AND IMAGING TECHNOLOGIES, PROCEEDINGS OF, 1998, 3253 : 155 - 164
  • [50] NEW TIME-OF-FLIGHT MASS SPECTROMETER
    KATZENSTEIN, HS
    FRIEDLAND, SS
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1955, 26 (04): : 324 - 327