Concurrent Validity and Reliability of a Handheld Dynamometer in Measuring Isometric Shoulder Rotational Strength

被引:10
|
作者
Chen, Bin [1 ]
Liu, Lifen [2 ]
Chen, Lincoln Bin [1 ]
Cao, Xianxin [1 ]
Han, Peng [1 ]
Wang, Chenhao [1 ]
Qi, Qi [1 ]
机构
[1] Tongji Univ, Sch Med, Shanghai Yangzhi Rehabil Hosp, Dept Phys Therapy, Shanghai, Peoples R China
[2] Tongji Univ, Sch Med, Shanghai, Peoples R China
关键词
handheld dynamometry; isokinetic dynamometer; external; internal; portability;
D O I
10.1123/jsr.2020-0021
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Context: Measuring isometric shoulder rotational strength is clinically important for evaluating motor disability in athletes with shoulder injuries. Recent evidence suggests that handheld dynamometry may provide a low-cost and portable method for the clinical assessment of isometric shoulder strength. Objective: To investigate the concurrent validity and the intrarater and interrater reliability of handheld dynamometry for measuring isometric shoulder rotational strength. Design: Cross-sectional study. Setting: Biomechanics laboratory. Participants: Thirty-nine young, healthy participants. Main Outcome Measures: The peak isometric strength of the internal rotators and external rotators, measured by handheld dynamometry (in newton) and isokinetic dynamometry (in newton meter). Interventions: Maximal isometric shoulder rotational strength was measured as participants lay supine with 90 degrees shoulder abduction, neutral rotation, 90 degrees elbow flexion, and forearm pronation. Measurements were performed independently by 2 different physiotherapists and in 3 different sessions to evaluate interrater and intrarater reliability. The data obtained by handheld dynamometry were compared with those obtained by isokinetic testing to evaluate concurrent validity. Results: The intraclass correlation coefficients for interrater reliability in measuring maximum isometric shoulder external and internal rotation strength were .914 (95% confidence interval [CI], .842-.954) and .842 (95% CI, .720-.914), respectively. The intrarater reliability values of the method for measuring maximal shoulder external and internal rotation strength were 0.865 (95% CI, 0.757-0.927) and 0.901 (95% CI, 0.820-0.947), respectively. The Pearson correlation coefficients between the handheld and isokinetic dynamometer measurements were.792 (95% CI, .575-.905) for external rotation strength and .664 (95% CI, .419-.839) for internal rotation strength. Conclusions: The handheld dynamometer showed good to excellent reliability and moderate to good validity in measuring maximum isometric shoulder rotational strength. Therefore, handheld dynamometry could be acceptable for health and sports professionals in field situations to evaluate maximum isometric shoulder rotational strength.
引用
收藏
页码:965 / 968
页数:4
相关论文
共 50 条
  • [1] Measuring Eccentric Strength of the Shoulder External Rotators Using a Handheld Dynamometer: Reliability and Validity
    Johansson, Fredrik R.
    Skillgate, Eva
    Lapauw, Mattis L.
    Clijmans, Dorien
    Deneulin, Valentijn P.
    Palmans, Tanneke
    Cools, Ann M.
    JOURNAL OF ATHLETIC TRAINING, 2015, 50 (07) : 719 - 725
  • [2] Assessment of isometric strength of the shoulder rotators in swimmers using a handheld dynamometer: a reliability study
    Conceicao, Ana
    Parraca, Jose
    Marinho, Daniel
    Costa, Mario
    Louro, Hugo
    Silva, Antonio
    Batalha, Nuno
    ACTA OF BIOENGINEERING AND BIOMECHANICS, 2018, 20 (04) : 113 - 119
  • [3] Test-retest reliability of isometric shoulder muscle strength measurement with a handheld dynamometer and belt
    Katoh, Munenori
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2015, 27 (06) : 1719 - 1722
  • [4] Validity and Reliability of the Kinvent Handheld Dynamometer in the Athletic Shoulder Test
    Olds, Margie
    McLaine, Sally
    Magni, Nico
    JOURNAL OF SPORT REHABILITATION, 2023, 32 (07) : 764 - 772
  • [5] The Concurrent Validity of a Hand-held versus a Stationary Dynamometer in Testing Isometric Shoulder Strength
    Roy, Jean-Sebastien
    MacDermid, Joy C.
    Orton, Brock
    Tran, Thomas
    Faber, Kenneth J.
    Drosdowech, Darren
    Athwal, George S.
    JOURNAL OF HAND THERAPY, 2009, 22 (04) : 320 - 326
  • [6] Concurrent validity of handheld dynamometer measurements for scapular protraction strength
    Liberatori Junior, Ricardo Marcos
    Netto, Walter Ansanello
    Carvalho, Gabriela Ferreira
    Zanca, Gisele Garcia
    Assan Zatiti, Salomao Chade
    Mattiello, Stela Marcia
    BRAZILIAN JOURNAL OF PHYSICAL THERAPY, 2019, 23 (03) : 228 - 235
  • [7] Relative Validity and Reliability of Isometric Lower Extremity Strength Assessment in Older Adults by Using a Handheld Dynamometer
    Grootswagers, Pol
    Vaes, Anouk M. M.
    Hangelbroek, Roland
    Tieland, Michael
    van Loon, Luc J. C.
    de Groot, Lisette C. P. G. M.
    SPORTS HEALTH-A MULTIDISCIPLINARY APPROACH, 2022, 14 (06): : 899 - 905
  • [8] Measuring seated hip extensor strength using a handheld dynamometer: an examination of the reliability and validity of the protocol
    Seko, Toshiaki
    Kumamoto, Tsuneo
    Miura, Sayo
    Kobayashi, Takumi
    Takahashi, Yui
    Kaneko, Ryousuke
    Morino, Akira
    Ito, Toshikazu
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2015, 27 (07) : 2179 - 2182
  • [9] Validity and reliability of a low-cost digital dynamometer for measuring isometric strength of lower limb
    Romero-Franco, Natalia
    Jimenez-Reyes, Pedro
    Montano-Munuera, Juan A.
    JOURNAL OF SPORTS SCIENCES, 2017, 35 (22) : 2179 - 2184
  • [10] Validity of the Handheld Dynamometer Compared with an Isokinetic Dynamometer in Measuring Peak Hip Extension Strength
    Keep, Heather
    Luu, Levana
    Berson, Ayli
    Garland, S. Jayne
    PHYSIOTHERAPY CANADA, 2016, 68 (01) : 15 - 22