Hydrophilic Interaction Liquid Chromatography-Electrospray Ionization Mass Spectrometry for Therapeutic Drug Monitoring of Metformin and Rosuvastatin in Human Plasma

被引:12
|
作者
Antonopoulos, Nikolaos [1 ]
Machairas, Giorgos [1 ]
Migias, George [2 ]
Vonaparti, Ariadni [3 ]
Brakoulia, Vasiliki [1 ]
Pistos, Constantinos [4 ]
Gennimata, Dimitra [5 ]
Panderi, Irene [1 ]
机构
[1] Univ Athens, Sch Pharm, Div Pharmaceut Chem, Lab Pharmaceut Anal, Athens 15771, Greece
[2] Gen Hosp Athens Alexandra, 80 Vas Sofias Ave, Athens 11528, Greece
[3] Qatar Doping Anal Lab, Sports City Rd,POB 27775, Doha, Qatar
[4] West Chester Univ, Dept Chem, W Chester, PA 19383 USA
[5] Gen Hosp Korgialenio Benakio Natl Red Cross, Erithrou Stavrou 1, Athens 11526, Greece
来源
MOLECULES | 2018年 / 23卷 / 07期
关键词
rosuvastatin; metformin; HILIC; LC-MS; therapeutic drug monitoring; N-DESMETHYL ROSUVASTATIN; SOLID-PHASE EXTRACTION; QUANTITATIVE-DETERMINATION; LC-MS/MS; HEALTHY-VOLUNTEERS; ANTIDIABETIC DRUGS; BIOLOGICAL-FLUIDS; QUANTIFICATION; VALIDATION; HYDROCHLORIDE;
D O I
10.3390/molecules23071548
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
In this work a hydrophilic interaction liquid chromatography/positive ion electrospray mass spectrometric assay (HILIC/ESI-MS) has been developed and fully validated for the quantitation of metformin and rosuvastatin in human plasma. Sample preparation involved the use of 100 mu L of human plasma, following protein precipitation and filtration. Metformin, rosuvastatin and 4-[2-(propylamino) ethyl] indoline 2 one hydrochloride (internal standard) were separated by using an X-Bridge-HILIC BEH analytical column (150.0 x 2.1 mm i.d., particle size 3.5 mu m) with isocratic elution. A mobile phase consisting of 12% (v/v) 15 mM ammonium formate water solution in acetonitrile was used for the separation and pumped at a flow rate of 0.25 mL min(-1). The linear range of the assay was 100 to 5000 ng mL(-1) and 2 to 100 ng mL(-1) for metformin and rosuvastatin, respectively. The current HILIC-ESI/MS method allows for the accurate and precise quantitation of metformin and rosuvastatin in human plasma with a simple sample preparation and a short a chromatographic run time (less than 15 min). Plasma samples from eight patients were further analysed proving the capability of the proposed method to support a wide range of clinical studies.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Analysis of rosuvastatin stress degradation behavior using liquid chromatography coupled to ultraviolet detection and electrospray ionization mass spectrometry
    Khedr, Alaa
    Belal, Fathalla
    Ibrahim, Fawzia
    Elawady, Tarek
    ANALYTICAL METHODS, 2013, 5 (22) : 6494 - 6502
  • [32] Liquid chromatography/mass spectrometry for therapeutic drug monitoring of immunosuppressants
    Deters, M
    Kaever, V
    Kirchner, GI
    ANALYTICA CHIMICA ACTA, 2003, 492 (1-2) : 133 - 145
  • [33] Development and validation of a sensitive method for simultaneous determination of rosuvastatin and N-desmethyl rosuvastatin in human plasma using liquid chromatography/negative electrospray ionization/tandem mass spectrometry
    Lee, H. K.
    Ho, C. S.
    Hu, M.
    Tomlinson, B.
    Wong, C. K.
    BIOMEDICAL CHROMATOGRAPHY, 2013, 27 (11) : 1369 - 1374
  • [34] Solid phase extraction and liquid chromatography-electrospray ionization-mass spectrometry for the determination of bencycloquidium bromide in human plasma
    Zhou, Wenjia
    Ding, Li
    Wang, Yongqing
    Sun, Luning
    Huang, Yao
    Hu, Linlin
    Chen, Xiaoping
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (10): : 897 - 901
  • [35] Determination of cyclobenzaprine in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry and its application in a pharmacokinetic study
    Xiang, Yi
    Zhou, Liping
    Qian, Zhenyu
    Peng, Kelong
    Li, Dongyan
    Chen, Xiaomei
    Jiang, Hongliang
    Zheng, Heng
    BIOMEDICAL CHROMATOGRAPHY, 2012, 26 (09) : 1083 - 1088
  • [36] Simultaneous determination of azilsartan and chlorthalidone in rat and human plasma by liquid chromatography-electrospray tandem mass spectrometry
    Ramakrishna, Rachumallu
    Puttrevu, Santosh Kumar
    Bhateria, Manisha
    Bala, Veenu
    Sharma, Vishnu L.
    Bhatta, Rabi Sankar
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 990 : 185 - 197
  • [37] Quantitative determination of armodafinil in human plasma by liquid chromatography-electrospray mass spectrometry: Application to a clinical study
    Chandasana, Hardik
    Kast, Johannes
    Bittman, Janina A.
    Derendorf, Hartmut
    BIOMEDICAL CHROMATOGRAPHY, 2018, 32 (11)
  • [38] Analysis of oligonucleotides by hydrophilic interaction liquid chromatography coupled to negative ion electrospray ionization mass spectrometry
    Gong, Lingzhi
    McCullagh, James S. O.
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (32) : 5480 - 5486
  • [39] Validation and application of a liquid chromatography-electrospray ionization mass spectrometric method for determination of mazindol in human plasma and urine
    de Oliveira, Marcella Herbstrith
    Lukasewicz Ferreira, Pamela Cristina
    Carlos, Graciela
    Salazar, Fernanda Rodrigues
    Bergold, Ana Maria
    Pechansky, Flavio
    Limberger, Renata Pereira
    Froehlich, Pedro Eduardo
    JOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODS, 2016, 79 : 1 - 6
  • [40] Liquid chromatography-electrospray mass spectrometry and tandem mass spectrometry of ceramides
    Raith, K
    Neubert, RHH
    ANALYTICA CHIMICA ACTA, 2000, 403 (1-2) : 295 - 303