Hydrophilic Interaction Liquid Chromatography-Electrospray Ionization Mass Spectrometry for Therapeutic Drug Monitoring of Metformin and Rosuvastatin in Human Plasma

被引:13
作者
Antonopoulos, Nikolaos [1 ]
Machairas, Giorgos [1 ]
Migias, George [2 ]
Vonaparti, Ariadni [3 ]
Brakoulia, Vasiliki [1 ]
Pistos, Constantinos [4 ]
Gennimata, Dimitra [5 ]
Panderi, Irene [1 ]
机构
[1] Univ Athens, Sch Pharm, Div Pharmaceut Chem, Lab Pharmaceut Anal, Athens 15771, Greece
[2] Gen Hosp Athens Alexandra, 80 Vas Sofias Ave, Athens 11528, Greece
[3] Qatar Doping Anal Lab, Sports City Rd,POB 27775, Doha, Qatar
[4] West Chester Univ, Dept Chem, W Chester, PA 19383 USA
[5] Gen Hosp Korgialenio Benakio Natl Red Cross, Erithrou Stavrou 1, Athens 11526, Greece
关键词
rosuvastatin; metformin; HILIC; LC-MS; therapeutic drug monitoring; N-DESMETHYL ROSUVASTATIN; SOLID-PHASE EXTRACTION; QUANTITATIVE-DETERMINATION; LC-MS/MS; HEALTHY-VOLUNTEERS; ANTIDIABETIC DRUGS; BIOLOGICAL-FLUIDS; QUANTIFICATION; VALIDATION; HYDROCHLORIDE;
D O I
10.3390/molecules23071548
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
In this work a hydrophilic interaction liquid chromatography/positive ion electrospray mass spectrometric assay (HILIC/ESI-MS) has been developed and fully validated for the quantitation of metformin and rosuvastatin in human plasma. Sample preparation involved the use of 100 mu L of human plasma, following protein precipitation and filtration. Metformin, rosuvastatin and 4-[2-(propylamino) ethyl] indoline 2 one hydrochloride (internal standard) were separated by using an X-Bridge-HILIC BEH analytical column (150.0 x 2.1 mm i.d., particle size 3.5 mu m) with isocratic elution. A mobile phase consisting of 12% (v/v) 15 mM ammonium formate water solution in acetonitrile was used for the separation and pumped at a flow rate of 0.25 mL min(-1). The linear range of the assay was 100 to 5000 ng mL(-1) and 2 to 100 ng mL(-1) for metformin and rosuvastatin, respectively. The current HILIC-ESI/MS method allows for the accurate and precise quantitation of metformin and rosuvastatin in human plasma with a simple sample preparation and a short a chromatographic run time (less than 15 min). Plasma samples from eight patients were further analysed proving the capability of the proposed method to support a wide range of clinical studies.
引用
收藏
页数:14
相关论文
共 40 条
[1]   Analytical Methods for the Determination of Rosuvastatin in Pharmaceutical Formulations and Biological Fluids: A Critical Review [J].
Angelo, Marilene Lopes ;
Moreira, Fernanda de Lima ;
Morais Ruela, Andre Luis ;
Araujo Santos, Ana Laura ;
Nunes Salgado, Herida Regina ;
de Araujo, Magali Benjamim .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2018, 48 (04) :317-329
[2]   Sequential hollow-fiber liquid phase microextraction for the determination of rosiglitazone and metformin hydrochloride (anti-diabetic drugs) in biological fluids [J].
Ben-Hander, Gazala Mohamed ;
Makahleh, Ahmad ;
Saad, Bahruddin ;
Saleh, Muhammad Idiris ;
Cheng, Kek Wan .
TALANTA, 2015, 131 :590-596
[3]   Hollow fiber liquid phase microextraction with in situ derivatization for the determination of trace amounts of metformin hydrochloride (anti-diabetic drug) in biological fluids [J].
Ben-Hander, Gazala Mohamed ;
Makahleh, Ahmad ;
Saad, Bahruddin ;
Saleh, Muhammad Idiris .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 941 :123-130
[4]  
Bretnall AE, 1998, ANAL PROF DRUG SUBST, V25, P243, DOI 10.1016/S0099-5428(08)60757-1
[5]  
Committee for Medicinal Products for Human Use (CHMP), 2015, EMEACHMPEWP192217200
[6]   Statin therapy on glycemic control in type 2 diabetic patients: A network meta-analysis [J].
Cui, J. Y. ;
Zhou, R. R. ;
Han, S. ;
Wang, T. S. ;
Wang, L. Q. ;
Xie, X. H. .
JOURNAL OF CLINICAL PHARMACY AND THERAPEUTICS, 2018, 43 (04) :556-570
[7]   Simultaneous Quantification of Antidiabetic Agents in Human Plasma by a UPLC-QToF-MS Method [J].
Fachi, Mariana Millan ;
Cerqueira, Leticia Bonancio ;
Leonart, Leticia Paula ;
Guimaraes de Francisco, Thais Martins ;
Pontarolo, Roberto .
PLOS ONE, 2016, 11 (12)
[8]   Liquid chromatography/negative ion electrospray tandem mass spectrometry method for the quantification of rosuvastatin in human plasma: Application to a pharmacokinetic study [J].
Gao, Jun ;
Zhong, Dafang ;
Duan, Xiaotao ;
Chen, Xiaoyan .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 856 (1-2) :35-40
[9]   Simultaneous assay of metformin and glibenclamide in human plasma based on extraction-less sample preparation procedure and LC/(APCI)MS [J].
Georgita, Cristina ;
Albu, Florin ;
David, Victor ;
Medvedovici, Andrei .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 854 (1-2) :211-218
[10]   Ultra-performance hydrophilic interaction LC-MS/MS for the determination of metformin in mouse plasma [J].
Hsieh, Yunsheng ;
Galviz, Gerica ;
Hwa, Joyce J. .
BIOANALYSIS, 2009, 1 (06) :1073-1079