Long-term stability of screen-printed pseudo-reference electrodes for electrochemical biosensors

被引:30
作者
Sopstad, Sindre [1 ]
Johannessen, Erik A. [1 ]
Seland, Frode [2 ]
Imenes, Kristin [1 ]
机构
[1] Univ Coll Southeast Norway, Inst Microsyst, Fac Technol Nat & Maritime Sci TNM, N-3184 Borre, Norway
[2] Norwegian Univ Sci & Technol, NTNU, Dept Mat Sci & Engn, N-7491 Trondheim, Norway
关键词
Reference electrodes; Biosensors; Screen-printing; Long-term stability; AG/AGCL REFERENCE ELECTRODE; STATE REFERENCE ELECTRODE; LIQUID-JUNCTION; GLUCOSE SENSOR; ADSORPTION; SILVER; CHLORINE; FABRICATION; IMPROVEMENT; CU(111);
D O I
10.1016/j.electacta.2018.08.045
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Pseudo reference electrodes forms an essential part of electrochemical transducers, where they are used to maintain a reference potential for the system. Yet, little is known about their long-term stability, and any drift may cause undesired changes in the sensor signal. This paper investigates the stability of the reference potential of five material systems of screen-printed reference electrodes. Their potential was continuously monitored for a duration of 40 days in a phosphate buffered solution, and any signal changes were corroborated with EDX elemental analyses, SEM micrographs and cyclic voltammetry. The electrodes were considered to be stable as long as they remained within 30 mV of their initial potential throughout the study. It was found that Ag/AgCl electrodes with a 3:1 atomic ratio kept a stable reference potential (+/- 2.2 mV), whereas Ag/AgCl electrodes with a 9:1 atomic ratio, despite showing good overall constancy of +/- 3.2 mV, seemed to statistically lose stability towards the end of the 40 day trial due to AgCl depletion through dissolution. The daily potential drift for the respective Ag/AgCl electrodes were -0.2 mV (3:1 ratio) and -0.1mV (9:1 ratio), suggesting a proportionality between the amount of dissociated AgCl close to the electrode surface and the initial AgCl loading. Electrodes consisting of only Ag showed tendencies towards a mixed potential contribution, which reduced the long-term stability (+/- 24.2 mV) as well as the longevity span (2 days). Ag/Pd electrodes proved to be more unstable (+/- 29.7 mV), with an average lifetime of around 3.5 days. Pt had the greatest potential instability (+/- 59.8 mV), rendering its average lifetime to less than a day. It was shown that electrodes which deviates from the Ag/AgCl equilibrium had the greatest potential variation with time. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:29 / 36
页数:8
相关论文
共 40 条
[1]   A chronopotentiometric approach for measuring chloride ion concentration [J].
Abbas, Yawar ;
Olthuis, Wouter ;
van den Berg, Albert .
SENSORS AND ACTUATORS B-CHEMICAL, 2013, 188 :433-439
[2]  
Austin L. G. G., 1965, DTIC DOCUMENT
[3]  
Bierbrauer J., 2017, INTRO CODING THEORY
[4]   DESIGN AND INVITRO STUDIES OF A NEEDLE-TYPE GLUCOSE SENSOR FOR SUBCUTANEOUS MONITORING [J].
BINDRA, DS ;
ZHANG, YN ;
WILSON, GS ;
STERNBERG, R ;
THEVENOT, DR ;
MOATTI, D ;
REACH, G .
ANALYTICAL CHEMISTRY, 1991, 63 (17) :1692-1696
[5]  
Ciobanu M, 2002, ELECTROANAL, V14, P989, DOI 10.1002/1521-4109(200208)14:14<989::AID-ELAN989>3.0.CO
[6]  
2-6
[7]   Thick film silver silver chloride reference electrodes [J].
Cranny, AWJ ;
Atkinson, JK .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1998, 9 (09) :1557-1565
[8]   Acoustic and hybrid 3D-printed electrochemical biosensors for the real-time immunodetection of liver cancer cells (HepG2) [J].
Damiati, Samar ;
Kupcu, Seta ;
Peacock, Martin ;
Eilenberger, Christoph ;
Zamzami, Mazin ;
Qadri, Ishtiaq ;
Choudhry, Hani ;
Sleytr, Uwe B. ;
Schuster, Bernhard .
BIOSENSORS & BIOELECTRONICS, 2017, 94 :500-506
[9]   Embeddable reference electrodes for corrosion monitoring of reinforced concrete structures [J].
Duffo, G. S. ;
Farina, S. B. ;
Giordano, C. M. .
MATERIALS AND CORROSION-WERKSTOFFE UND KORROSION, 2010, 61 (06) :480-489
[10]   CHLORINE ADSORPTION ON THE (111) FACES OF PD AND PT [J].
ERLEY, W .
SURFACE SCIENCE, 1980, 94 (2-3) :281-292