Chiral separation of beta-blockers by high-performance liquid chromatography and determination of bisoprolol enantiomers in surface waters

被引:9
作者
Pocrnic, Marijana [1 ]
Ansorge, Martin [2 ]
Dovhunova, Magda [2 ]
Habinovec, Iva [1 ]
Tesarova, Eva [2 ]
Galic, Nives [1 ]
机构
[1] Univ Zagreb, Fac Sci, Dept Chem, Horvatovac 102 A, Zagreb 10000, Croatia
[2] Charles Univ Prague, Fac Sci, Dept Phys & Macromol Chem, Prague, Czech Republic
来源
ARHIV ZA HIGIJENU RADA I TOKSIKOLOGIJU-ARCHIVES OF INDUSTRIAL HYGIENE AND TOXICOLOGY | 2020年 / 71卷 / 01期
关键词
acebutolol; atenolol; Chirobiotic V column; Croatia; Czech Republic; enantioseparation; HPLC; labetalol; metoprolol; water analysis; SOLID-PHASE EXTRACTION; WASTE-WATER; STATIONARY PHASES; ALPHA-HYDROXYMETOPROLOL; ILLICIT DRUGS; PHARMACEUTICALS; PROPRANOLOL; METOPROLOL; TOXICITY; AGENTS;
D O I
10.2478/aiht-2020-71-3318
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Beta-blockers are chiral compounds with enantiomers that have different bioactivity, which means that while one is active, the other can be inactive or even harmful. Due to their high consumption and incomplete degradation in waste water, they may reach surface waters and affect aquatic organisms. To address this issue we developed a chromatographic method suitable for determining beta-blocker enantiomers in surface waters. It was tested on five beta-blockers (acebutolol, atenolol, bisoprolol, labetalol and metoprolol) and validated on bisoprolol enantiomers. Good enantioseparation of all analysed beta-blockers was achieved on the Chirobiotic V column with the mobile phase composed of methanol/acetic acid/triethylamine (100/0.20/0.15 v/v/v) at a flow rate of 0.5 mL/min and colt= temperature of 45 degrees C. Method proved to be linear in the concentration range from 0.075 gginiL to 5 mu g/mL, and showed good recovery. The limits of bisoprolol enantiomer detection were 0.025 mu g/mL and 0.026 mu g/mL and of quantification 0.075 mu g/mL and 0.075 mu g/mL. Despite its limitations, it seems to be a promising method for bisoprolol enantiomer analysis in surface water samples. Further research could focus on waste water analysis, where enantiomer concentrations may be high. Furthermore, transferring the method to a more sensitive one such as liquid chromatography coupled with tandem mass spectrometry and using ammonium acetate as the mobile phase additive instead of acetic acid and triethylamine would perhaps yield much lower limits of detection and quantification.
引用
收藏
页码:56 / 62
页数:7
相关论文
共 25 条
[1]  
Agency for Medicinal Products and Medical Devices of Croatia (HALMED), ANN REP DRUG UT 2017
[2]   Chiral separation of β-adrenergic blockers on CelluCoat column by HPLC [J].
Ali, Imran ;
Gaitonde, Vinay D. ;
Aboul-Enein, Hassan Y. ;
Hussain, Afzal .
TALANTA, 2009, 78 (02) :458-463
[3]   A NEW APPROACH FOR THE DIRECT RESOLUTION OF RACEMIC BETA-ADRENERGIC BLOCKING-AGENTS BY HPLC [J].
ARMSTRONG, DW ;
CHEN, S ;
CHANG, C ;
CHANG, S .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1992, 15 (03) :545-556
[4]   Using chiral liquid chromatography quadrupole time-of-flight mass spectrometry for the analysis of pharmaceuticals and illicit drugs in surface and wastewater at the enantiomeric level [J].
Bagnall, J. P. ;
Evans, S. E. ;
Wort, M. T. ;
Lubben, A. T. ;
Kasprzyk-Hordern, B. .
JOURNAL OF CHROMATOGRAPHY A, 2012, 1249 :115-129
[5]   Chiral analysis of metoprolol and two of its metabolites, α-hydroxymetoprolol and deaminated metoprolol, in wastewater using liquid chromatography-tandem mass spectrometry [J].
Barclay, Victoria K. H. ;
Tyrefors, Niklas L. ;
Johansson, I. Monika ;
Pettersson, Curt E. .
JOURNAL OF CHROMATOGRAPHY A, 2012, 1269 :208-217
[6]   Method Development Strategy and Applications Update for CHIROBIOTIC Chiral Stationary Phases [J].
Beesley, Thomas E. ;
Lee, Jauh-Tzuoh .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2009, 32 (11-12) :1733-1767
[7]   Comparison of vancomycin-based stationary phases with different chiral selector coverage for enantioselective separation of selected drugs in high-performance liquid chromatography [J].
Bosáková, Z ;
Curínová, E ;
Tesarová, E .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1088 (1-2) :94-103
[8]   Use of Toxicity Assays for Enantiomeric Discrimination of Pharmaceutical Substances [J].
De Andres, Fernando ;
Castaneda, Gregorio ;
Rios, Angel .
CHIRALITY, 2009, 21 (08) :751-759
[9]   Determination of chiral pharmaceuticals and illicit drugs in wastewater and sludge using microwave assisted extraction, solid-phase extraction and chiral liquid chromatography coupled with tandem mass spectrometry [J].
Evans, Sian E. ;
Davies, Paul ;
Lubben, Anneke ;
Kasprzyk-Hordern, Barbara .
ANALYTICA CHIMICA ACTA, 2015, 882 :112-126
[10]   Development of an HPLC method for the quantitation of bisoprolol enantiomers in pharmaceutical products using a teicoplanin chiral stationary phase and fluorescence detection [J].
Hefnawy, Mohamed M. ;
Sultan, Maha A. ;
Al-Shehri, Mona M. .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2006, 29 (20) :2901-2914