CT-guided percutaneous fine-needle aspiration biopsy of pulmonary nodules measuring 10 mm or less

被引:83
作者
Ng, Y. L.
Patsios, D.
Roberts, H.
Walsham, A.
Paul, N. S.
Chung, T.
Herman, S.
Weisbrod, G.
机构
[1] Mt Sinai Hosp, Toronto, ON M5G 2C4, Canada
[2] Univ Hlth Network, Thorac Div, Joint Dept Med Imaging, Toronto, ON, Canada
关键词
D O I
10.1016/j.crad.2007.09.003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To determine the value of computed tomography (CT)-guided fine-needle aspiration biopsy (FNAB) of small pulmonary nodules measuring 10 mm or less. MATERIAL AND METHODS: CT-guided FNABs of 55 nodules, measuring 10 mm or less, were performed between January 2003 and February 2006. A coaxial technique was used, with an outer 19 G Bard Truguide needle and inner 22 G disposable Greene biopsy needle. Adequacy of specimens was assessed on-site by a cytotechnologist. The sizes of the nodules, distance from pleura, number of pleural punctures and aspirates, complications encountered, cytological diagnosis, and outcome were recorded. RESULTS: The mean nodule diameter was 9 mm (range 5-10 mm). The average distance from the costal pleura was 31 mm (range 0-88 mm). In 50 of the 55 FNABs, the pleura was crossed once. An average of four aspirates was performed per case. Twenty-five FNABs (45.5%) were adequate for diagnosis (24 malignant and one tuberculosis). In 11 cases, where no definite diagnosis was made following FNAB, the outcome was not affected. In 10 cases, samples were insufficient for diagnosis and the nodules were subsequently diagnosed as malignant. Eight cases were excluded in the final analysis as follow-up details were unavailable. The sensitivity for malignancy and overall accuracy were 67.7 and 78.8%, respectively. Pneumothorax occurred in 29 (52.7%) patients, with five (9.1%) requiring thoracostomy tubes. CONCLUSION: CT-guided FNAB is a useful tool. in the diagnosis and management of small pulmonary nodules, despite the tower diagnostic accuracy and higher complication rate than those of larger pulmonary lesions. (C) 2007 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:272 / 277
页数:6
相关论文
共 23 条
[1]  
AUERBACH O, 1991, CANCER, V68, P1973, DOI 10.1002/1097-0142(19911101)68:9<1973::AID-CNCR2820680921>3.0.CO
[2]  
2-Z
[3]  
BARSKY SH, 1994, CANCER-AM CANCER SOC, V73, P1163, DOI 10.1002/1097-0142(19940215)73:4<1163::AID-CNCR2820730407>3.0.CO
[4]  
2-J
[5]   Routine addition of an automated biopsy device to fine-needle aspiration of the lung: A prospective assessment [J].
Boiselle, PM ;
Shepard, JAO ;
Mark, EJ ;
Szyfelbein, WM ;
Fan, CM ;
Slanetz, PJ ;
TrotmanDickenson, B ;
Halpern, EF ;
McLoud, TC .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (03) :661-666
[6]   Transthoracic needle aspiration biopsy: Variables that affect risk of pneumothorax [J].
Cox, JE ;
Chiles, C ;
McManus, CM ;
Aquino, SL ;
Choplin, RH .
RADIOLOGY, 1999, 212 (01) :165-168
[7]   Solitary pulmonary nodules: Part II. Evaluation of the indeterminate nodule [J].
Erasmus, JJ ;
McAdams, HP ;
Connolly, JE .
RADIOGRAPHICS, 2000, 20 (01) :59-66
[8]   Evaluation of primary pulmonary carcinoid tumors using FDG PET [J].
Erasmus, JJ ;
McAdams, HP ;
Patz, EF ;
Coleman, RE ;
Ahuja, V ;
Goodman, PC .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (05) :1369-1373
[9]   Accuracy of positron emission tomography for diagnosis of pulmonary nodules and mass lesions - A meta-analysis [J].
Gould, MK ;
Maclean, CC ;
Kuschner, WG ;
Rydzak, CE ;
Owens, DK .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2001, 285 (07) :914-924
[10]   Early Lung Cancer Action Project: overall design and findings from baseline screening [J].
Henschke, CI ;
McCauley, DI ;
Yankelevitz, DF ;
Naidich, DP ;
McGuinness, G ;
Miettinen, OS ;
Libby, DM ;
Pasmantier, MW ;
Koizumi, J ;
Altorki, NK ;
Smith, JP .
LANCET, 1999, 354 (9173) :99-105