Determination of ATP via the photochemical generation of hydrogen peroxide using flow injection luminol chemiluminescence detection

被引:97
作者
Pérez-Ruiz, T [1 ]
Martínez-Lozano, C [1 ]
Tomás, V [1 ]
Martín, J [1 ]
机构
[1] Univ Murcia, Fac Chem, Dept Analyt Chem, E-30071 Murcia, Spain
关键词
ATP; 9,10-anthraquinone-2,6-disulfonate; photochemical reaction; flow injection; chemiluminescence detection;
D O I
10.1007/s00216-003-2071-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The determination of ATP using the coupling between a photochemical reaction and a chemiluminescence reaction in a flow injection (FI) system is described. The method is based on the reaction of glucose with ATP catalyzed by hexokinase and Mg2+ ions. The glucose that is not consumed by ATP is subsequently photooxidized using 9,10-anthraquinone-2,6-disulfonate as a sensitizer. The hydrogen peroxide produced in the photochemical reaction is monitored through the chemiluminescence reaction with luminol catalyzed by hematine. There is a linear relationship between the decrease in the chemiluminescence response and the ATP concentration at a constant concentration of glucose. Under the optimum conditions, the calibration graph is linear in the range 0.20-50.5 mg L-1 with a throughput of 25 samples per hour and relative standard deviations between +/-0.62 and +/-1.42%. The limit of detection is 0.07 mg L-1. The method was used for the determination of ATP in pharmaceuticals, milk, and soils.
引用
收藏
页码:189 / 194
页数:6
相关论文
共 50 条
[41]   Flow injection chemiluminescence analysis of phenolic compounds using the NCS-luminol system [J].
Behzad Haghighi ;
Reza Dadashvand .
Analytical and Bioanalytical Chemistry, 2006, 384 :1246-1253
[42]   Determination of trace amounts of dopamine by flow-injection analysis coupled with luminol-Ag(III) complex chemiluminescence detection [J].
Xu, Xiangdong ;
Shi, Hongmei ;
Ma, Li ;
Kang, Weijun ;
Li, Shan .
LUMINESCENCE, 2011, 26 (02) :93-100
[43]   Determination of pipernidic acid by flow injection analysis with chemiluminescence detection [J].
Li, LQ ;
Wu, YY ;
Feng, ML ;
Lü, JR .
CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2002, 30 (02) :169-171
[44]   Determination of promethazine hydrochloride by flow injection analysis with chemiluminescence detection [J].
Xue, YY ;
He, YH ;
Feng, ML ;
Lu, JR .
CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 27 (04) :427-429
[45]   Determination of codeine in process streams using flow-injection analysis with chemiluminescence detection [J].
Barnett, NW ;
Bowser, TA ;
Gerardi, RD ;
Smith, B .
ANALYTICA CHIMICA ACTA, 1996, 318 (03) :309-317
[46]   Determination of iodide by detection of iodine using gas-diffusion flow injection and chemiluminescence [J].
Ratanawimarnwong, N ;
Amomthammarong, N ;
Choengchan, N ;
Chaisuwan, P ;
Amatatongchai, M ;
Wilairat, P ;
McKelvie, ID ;
Nacapricha, D .
TALANTA, 2005, 65 (03) :756-761
[47]   Selective determination of amino acids using flow injection analysis coupled with chemiluminescence detection [J].
Costin, JW ;
Francis, PS ;
Lewis, SW .
ANALYTICA CHIMICA ACTA, 2003, 480 (01) :67-77
[48]   Determination of N-methylcarbamate pesticides using flow injection with photoinduced chemiluminescence detection [J].
Lopez-Paz, Jose Luis ;
Catala-Icardo, Monica ;
Langa-Sanchez, Adrian .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2014, 94 (06) :606-617
[49]   Determination of Dopamine Using the Alkaline Luminol-Hydrogen Peroxide System for Sequential Injection-Zone Fluidics Analysis [J].
van Staden, Jacobus Frederick ;
State, Ramona .
ANALYTICAL LETTERS, 2016, 49 (17) :2783-2792
[50]   Flow injection chemiluminescence determination of cephalosporin antibiotics by their enhancing effects on luminol-potassium periodate system [J].
Yao, H ;
Tang, YH ;
Li, YH ;
Sun, YY .
ANALYTICAL LETTERS, 2003, 36 (14) :2975-2983