Determination of ATP via the photochemical generation of hydrogen peroxide using flow injection luminol chemiluminescence detection

被引:97
作者
Pérez-Ruiz, T [1 ]
Martínez-Lozano, C [1 ]
Tomás, V [1 ]
Martín, J [1 ]
机构
[1] Univ Murcia, Fac Chem, Dept Analyt Chem, E-30071 Murcia, Spain
关键词
ATP; 9,10-anthraquinone-2,6-disulfonate; photochemical reaction; flow injection; chemiluminescence detection;
D O I
10.1007/s00216-003-2071-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The determination of ATP using the coupling between a photochemical reaction and a chemiluminescence reaction in a flow injection (FI) system is described. The method is based on the reaction of glucose with ATP catalyzed by hexokinase and Mg2+ ions. The glucose that is not consumed by ATP is subsequently photooxidized using 9,10-anthraquinone-2,6-disulfonate as a sensitizer. The hydrogen peroxide produced in the photochemical reaction is monitored through the chemiluminescence reaction with luminol catalyzed by hematine. There is a linear relationship between the decrease in the chemiluminescence response and the ATP concentration at a constant concentration of glucose. Under the optimum conditions, the calibration graph is linear in the range 0.20-50.5 mg L-1 with a throughput of 25 samples per hour and relative standard deviations between +/-0.62 and +/-1.42%. The limit of detection is 0.07 mg L-1. The method was used for the determination of ATP in pharmaceuticals, milk, and soils.
引用
收藏
页码:189 / 194
页数:6
相关论文
共 50 条
  • [31] Determination of hydroxycamptothecinum by flow injection analysis with chemiluminescence detection
    Li Liqing
    Lin, Guan
    Ming, Su
    Sun Hanwen
    [J]. JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2007, 21 (06) : 356 - 362
  • [32] Determination of norfloxacin by flow injection analysis with chemiluminescence detection
    Sun, Han-wen
    Li, Li-qing
    Chen, Xue-yan
    Shi, Hong-mei
    Lue, Yun-kai
    [J]. CANADIAN JOURNAL OF ANALYTICAL SCIENCES AND SPECTROSCOPY, 2006, 51 (02): : 100 - 107
  • [33] DETERMINATION OF ASCORBIC-ACID BY FLOW-INJECTION WITH CHEMILUMINESCENCE DETECTION
    ALWARTHAN, AA
    [J]. ANALYST, 1993, 118 (06) : 639 - 642
  • [34] A flow injection chemiluminescence method for the determination of lincomycin in serum using a diperiodato-cuprate (III)-luminol system
    Hu, Yufei
    Li, Gongke
    Zhang, Zhujun
    [J]. LUMINESCENCE, 2011, 26 (05) : 313 - 318
  • [35] UV digestion of seawater samples prior to the determination of copper using flow injection with chemiluminescence detection
    Achterberg, EP
    Braungardt, CB
    Sandford, RC
    Worsfold, PJ
    [J]. ANALYTICA CHIMICA ACTA, 2001, 440 (01) : 27 - 36
  • [36] DETERMINATION OF TRACE AMOUNTS OF UREA BY USING FLOW-INJECTION WITH CHEMILUMINESCENCE DETECTION
    HU, XC
    TAKENAKA, N
    KITANO, M
    BANDOW, H
    MAEDA, Y
    HATTORI, M
    [J]. ANALYST, 1994, 119 (08) : 1829 - 1833
  • [37] Determination of eugenol using flow injection analysis with potassium permanganate chemiluminescence detection
    Xu, Hun
    [J]. ISTM/2007: 7TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-7, CONFERENCE PROCEEDINGS, 2007, : 5109 - 5112
  • [38] Flow-injection inhibition chemiluminescence determination of indapamide based on luminol-ferricyanide reaction
    Wang, ZP
    Zhang, ZJ
    Zhang, XO
    Fu, ZF
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 35 (01) : 1 - 7
  • [39] Flow-Injection Chemiluminescence Determination of Lisinopril Using Luminol-KMnO4 Reaction Catalyzed by Silver Nanoparticles
    Li, Yinhuan
    Li, Yankun
    Yang, Yun
    [J]. APPLIED SPECTROSCOPY, 2011, 65 (04) : 376 - 381
  • [40] Flow injection chemiluminescence analysis of phenolic compounds using the NCS-luminol system
    Haghighi, B
    Dadashvand, R