Enzyme-assisted extraction and liquid chromatography-inductively coupled plasma mass spectrometry for the determination of arsenic species in fish

被引:22
|
作者
Zhao, Fa [1 ]
Liu, Yanming [1 ]
Zhang, Xiqi [1 ]
Dong, Rui [1 ]
Yu, Wenjiang [1 ]
Liu, Yanfang [2 ]
Guo, Zhimou [2 ]
Liang, Xinmiao [2 ]
Zhu, Jianhua [1 ]
机构
[1] Shandong Inst Food & Drug Control, Jinan 250100, Shandong, Peoples R China
[2] Chinese Acad Sci, Dalian Inst Chem Phys, Dalian, Peoples R China
关键词
Fish; Arsenic species; Protease; Ammonium carbonate; Kinetic energy discrimination; HPLC-ICP-MS; ATOMIC-ABSORPTION-SPECTROMETRY; SOLID-PHASE EXTRACTION; HPLC-ICP-MS; MULTIELEMENTAL SPECIATION ANALYSIS; WATER SAMPLES; FLUORESCENCE SPECTROMETRY; DRINKING-WATER; SEPARATION; SEAFOOD; SELENIUM;
D O I
10.1016/j.chroma.2018.08.068
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A sensitive, simple and rapid method for the simultaneous determination of eleven arsenic species has been developed. A high performance liquid chromatography-inductively coupled plasma mass spectrometry (HPLC-ICP-MS) technique was used for the analysis of eleven arsenic species in less than 17 min. Different extraction solutions were explored and the recovery results using water and aqueous acidic solvents, aqueous organic solvents and enzymes showed that 40 mg protease with 0.75 mL 0.5% hydrochloric acid (v/v) as the extraction agent gave the best experimental results. Species separation with ammonium carbonate solution as the mobile phase was conducted on an anion-exchange chromatographic column using gradient elution. The column temperature was 20 degrees C and kinetic energy discrimination (KED) was employed to eliminate spectral interference. The use of KED mode effectively removed interference from (ArCl)-Ar-75. The detection limit (L-D) of the method was in the range of 0.11-0.59 mu g kg(-1). Repeatability values obtained for spiked real fish samples were in the range of 1.1%-7.6%. Accuracy was calculated based on the analysis of spiked real fish samples at five concentration levels. Obtained recoveries were 91%-106%. The validated method was used in a pilot study to analyze real samples of fish, the organic arsenic especially AsB was the major arsenic specie present in the analyzed samples, only trace amount of inorganic arsenic were detected. The analytical method should improve the assessment of human exposure associated with arsenic intake from fish. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:48 / 58
页数:11
相关论文
共 50 条
  • [1] Speciation of Arsenic in Fish by High-Performance Liquid Chromatography-Inductively Coupled Plasma-Mass Spectrometry
    Ozcan, Sefika
    Bakirdere, Sezgin
    Ataman, Osman Yavuz
    ANALYTICAL LETTERS, 2016, 49 (15) : 2501 - 2512
  • [2] Determination of five arsenic species in rice by liquid chromatography-inductively coupled plasma-mass spectrometry
    Gong Jiadi
    Cao Xiaolin
    Cao Zhaoyun
    Bian Yingfang
    Yu Shasha
    Chen Mingxue
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2014, 32 (07) : 717 - 722
  • [3] DETERMINATION OF ARSENIC SPECIES IN FISH BY DIRECTLY COUPLED HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY-INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY
    BRANCH, S
    EBDON, L
    ONEILL, P
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (01) : 33 - 37
  • [4] Measurement of arsenic species in marine macroalgae by microwave-assisted extraction and high performance liquid chromatography-inductively coupled plasma mass spectrometry
    Tukai, R
    Maher, WA
    McNaught, IJ
    Ellwood, MJ
    ANALYTICA CHIMICA ACTA, 2002, 457 (02) : 173 - 185
  • [5] Determination of selenium urinary metabolites by high temperature liquid chromatography-inductively coupled plasma mass spectrometry
    Terol, A.
    Ardini, F.
    Basso, A.
    Grotti, M.
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1380 : 112 - 119
  • [6] Determination of trace mercury species by high performance liquid chromatography-inductively coupled plasma mass spectrometry after cloud point extraction
    Chen, Haiting
    Chen, Jianguo
    Jin, Xianzhong
    Wei, Danyi
    JOURNAL OF HAZARDOUS MATERIALS, 2009, 172 (2-3) : 1282 - 1287
  • [7] Determination of arsenic compounds in beverages by high-performance liquid chromatography-inductively coupled plasma mass spectrometry
    Coelho, NMM
    Coelho, LM
    de Lima, ES
    Pastor, A
    de la Guardia, M
    TALANTA, 2005, 66 (04) : 818 - 822
  • [8] Measurement of arsenic species in marine sediments by high-performance liquid chromatography-inductively coupled plasma mass spectrometry
    Ellwood, MJ
    Maher, WA
    ANALYTICA CHIMICA ACTA, 2003, 477 (02) : 279 - 291
  • [9] Determination of vanadium species in sediment, mussel and fish muscle tissue samples by liquid chromatography-inductively coupled plasma-mass spectrometry
    Colina, M
    Gardiner, PHE
    Rivas, Z
    Troncone, F
    ANALYTICA CHIMICA ACTA, 2005, 538 (1-2) : 107 - 115
  • [10] DETERMINATION OF ORGANOTIN COMPOUNDS IN WINE BY MICROWAVE-ASSISTED EXTRACTION AND HIGH PERFORMANCE LIQUID CHROMATOGRAPHY-INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY
    Liu, Ying-Xia
    Wan, Yi-Qun
    Guo, Lan
    ANALYTICAL LETTERS, 2014, 47 (02) : 343 - 355