Stability indicating RP-HPLC method for the determination of flubendazole in pharmaceutical dosage forms

被引:5
作者
Abdelwahab, Nada S. [1 ]
Abdelrahman, Maha M. [1 ]
机构
[1] Beni Suef Univ, Fac Pharm, Dept Pharmaceut Analyt Chem, Bani Suwayf 62514, Egypt
关键词
9 BASIC PHARMACEUTICALS; SOLID-PHASE EXTRACTION; LIQUID; METABOLITES; ARRAY; WATER;
D O I
10.1039/c4ra11758a
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This paper presents a stability study of the drug flubendazole (FLUB) - a benzimidazole carbamate derivative with anthelmintic activity. In order to investigate the stability of the drug, FLUB was subjected to stress degradation under different conditions, as recommended by the International Conference on Harmonization (ICH). A validated HPLC-photodiode array detector (DAD) method was established to resolve FLUB from all its degradation products obtained under acidic, basic, neutral, oxidation, photo-degradation, and thermal conditions, and also from its suspension additives. Chromatographic separation was achieved on a ZORBAX Eclipse Plus C18 column in an isocratic mode of elution using a mixture of water : acetonitrile (50 : 50, v/v) as a mobile phase, at a flow rate of 1 mL min(-1), where FLUB was well resolved from all its degradation products at a t(R) of 5.35 min. The thermostated column compartment (TCC) was adjusted to 25 degrees C and the effluent was monitored by a photo-diode array detector at 254 nm, and FLUB was found to be linear in the range of 0.5-10 mu g mL(-1). The method was validated in terms of accuracy, precision, specificity, robustness, and ruggedness, as per USP guidelines. It was successfully applied to quantify FLUB in bulk powder and in pharmaceutical formulations with complete resolution between FLUB and its suspension additives. Statistical analyses between the suggested method and the official HPLC method using student's-t and F-ratio tests reveal that the suggested method is as accurate and precise as the reported one.
引用
收藏
页码:10927 / 10935
页数:9
相关论文
共 22 条
[1]  
[Anonymous], 2003, ICH STAB TEST NEW DR
[2]  
[Anonymous], 2008, EUROPEAN PHARMACOPOE, P2024
[3]  
[Anonymous], 2012, J CHROMATOGR SEP TEC
[4]  
[Anonymous], 2000, AN PROC METH VAL CHE
[5]  
[Anonymous], 1996, ICH STAB TEST PHOT T
[6]  
Budavaried S, 2002, MERCK INDEX ENCY CHE
[7]   Comparison of two different isolation methods of benzimidazoles and their metabolites in the bovine liver by solid-phase extraction and liquid chromatography-diode array detection [J].
Caprioli, Giovanni ;
Cristalli, Gloria ;
Galarini, Roberta ;
Giacobbe, Dania ;
Ricciutelli, Massimo ;
Vittori, Sauro ;
Zuo, Yanting ;
Sagratini, Gianni .
JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (11) :1779-1785
[8]   Determination of flubendazole and its metabolites in eggs and poultry muscle with liquid chromatography-tandem mass spectrometry [J].
De Ruyck, H ;
Daeseleire, E ;
Grijspeerdt, K ;
De Ridder, H ;
Van Renterghem, R ;
Huyghebaert, G .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2001, 49 (02) :610-617
[9]   Rapid determination of the antiparasitic drugs flubendazole and febantel in feeds by HPLC with ultraviolet detection [J].
Dusi, G ;
Gamba, V ;
Faggionato, E .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 38 (02) :375-379
[10]  
El-Enany N., 2003, Farmaco (Lausanne), V58, P613, DOI 10.1016/S0014-827X(03)00081-8