Dependence of apparent diffusion coefficient measurement on diffusion gradient direction and spatial position - A quality assurance intercomparison study of forty-four scanners for quantitative diffusion-weighted imaging

被引:35
作者
Fedeli, Luca [1 ]
Belli, Giacomo [2 ]
Ciccarone, Antonio [3 ]
Coniglio, Angela [4 ]
Esposito, Marco [5 ]
Giannelli, Marco [6 ]
Mazzoni, Lorenzo Nicola [7 ]
Nocetti, Luca [8 ]
Sghedoni, Roberto [9 ]
Tarducci, Roberto [10 ]
Altabella, Luisa [11 ]
Belligotti, Eleonora [12 ]
Benelli, Matteo [13 ]
Betti, Margherita [13 ]
Caivano, Rocchina [14 ]
Carni, Marco [15 ]
Chiappiniello, Andrea [10 ]
Cimolai, Sara [16 ]
Cretti, Fabiola [17 ]
Fulcheri, Christian [10 ]
Gasperi, Chiara [18 ]
Giacometti, Mara [19 ]
Levrero, Fabrizio [20 ]
Lizio, Domenico [21 ]
Maieron, Marta [22 ]
Marzi, Simona [23 ]
Mascaro, Lorella [24 ]
Mazzocchi, Silvia [5 ]
Meliado, Gabriele [25 ]
Morzenti, Sabrina [26 ]
Noferini, Linhsia [27 ]
Oberhofer, Nadia [28 ]
Quattrocchi, Maria Grazia [27 ]
Ricci, Alessandra [29 ]
Taddeucci, Adriana [2 ]
Tenori, Leonardo [30 ]
Luchinat, Claudio [30 ]
Gobbi, Gianni [31 ]
Gori, Cesare [1 ]
Busoni, Simone [2 ]
机构
[1] Univ Firenze, Florence, Italy
[2] AOU Careggi, Florence, Italy
[3] AOU Mayer, Florence, Italy
[4] AO Fatebene Fratelli, Rome, Italy
[5] AUSL Toscana Ctr, Florence, Italy
[6] AOU Pisana, Pisa, Italy
[7] AUSL Toscana Ctr, Pistoia, Italy
[8] AOU Policlin Modena, Modena, Italy
[9] AUSL IRCCS Reggio Emilia, Reggio Emilia, Italy
[10] AOU Perugia, Perugia, Italy
[11] Osped San Raffaele, Milan, Italy
[12] Osped Riuniti Marche Nord, Pesaro, Italy
[13] AUSL Toscana Ctr, Prato, Italy
[14] IRCCS CROB, Rionero In Vulture, PZ, Italy
[15] AOU Policlin Umberto I, Rome, Italy
[16] ULSS 2, Treviso, Italy
[17] Osped Riuniti Bergamo, Bergamo, Italy
[18] AUSL Toscana Sud Est, Arezzo, Italy
[19] Osped Riuniti, Ancona, Italy
[20] Policlin San Martino, Genoa, Italy
[21] ASST Niguarda, Milan, Italy
[22] ASUI Udine S Maria Misericordia, Udine, Italy
[23] Ist Regina Elena, Rome, Italy
[24] ASST Spedali Riuniti, Brescia, Italy
[25] AOUI Verona, Verona, Italy
[26] ASST Monza, Monza, Italy
[27] AUSL Toscana Nord Ovest, Lucca, Italy
[28] AS Alto Adige, Bolzano, Italy
[29] ASL Viterbo, Viterbo, Italy
[30] Univ Firenze, Magnet Resonance Ctr CERM, Florence, Italy
[31] Univ Perugia, Perugia, Italy
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2018年 / 55卷
关键词
MRI; PHANTOM; VALUES;
D O I
10.1016/j.ejmp.2018.09.007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To propose an MRI quality assurance procedure that can be used for routine controls and multi-centre comparison of different MR-scanners for quantitative diffusion-weighted imaging (DWI). Materials and methods: 44 MR-scanners with different field strengths (1 T, 1.5 T and 3 T) were included in the study. DWI acquisitions (b-value range 0-1000 s/mm(2)), with three different orthogonal diffusion gradient directions, were performed for each MR-scanner. All DWI acquisitions were performed by using a standard spherical plastic doped water phantom. Phantom solution ADC value and its dependence with temperature was measured using a DOSY sequence on a 600 MHz NMR spectrometer. Apparent diffusion coefficient (ADC) along each diffusion gradient direction and mean ADC were estimated, both at magnet isocentre and in six different position 50 mm away from isocentre, along positive and negative AP, RL and HF directions. Results: A good agreement was found between the nominal and measured mean ADC at isocentre: more than 90% of mean ADC measurements were within 5% from the nominal value, and the highest deviation was 11.3%. Away from isocentre, the effect of the diffusion gradient direction on ADC estimation was larger than 5% in 47% of included scanners and a spatial non uniformity larger than 5% was reported in 13% of centres. Conclusion: ADC accuracy and spatial uniformity can vary appreciably depending on MR scanner model, sequence implementation (i.e. gradient diffusion direction) and hardware characteristics. The DWI quality assurance protocol proposed in this study can be employed in order to assess the accuracy and spatial uniformity of estimated ADC values, in single-as well as multi-centre studies.
引用
收藏
页码:135 / 141
页数:7
相关论文
共 31 条
  • [21] Diffusion-weighted magnetic resonance imaging in the prediction and assessment of chemotherapy outcome in liver metastases
    Mungai, Francesco
    Pasquinelli, Filippo
    Mazzoni, Lorenzo Nicola
    Virgili, Gianni
    Ragozzino, Alfonso
    Quaia, Emilio
    Morana, Giovanni
    Giovagnoni, Andrea
    Grazioli, Luigi
    Colagrande, Stefano
    [J]. RADIOLOGIA MEDICA, 2014, 119 (08): : 625 - 633
  • [22] Diffusion Weighted MR and Apparent Diffusion Coefficient Measurement in Classification and Characterization of Noncystic Focal Liver Lesions: Does a Clinical Role Exist?
    Mungai, Francesco
    Morone, Mario
    Villanacci, Alberta
    Bondioni, Maria Pia
    Mazzoni, Lorenzo Nicola
    Grazioli, Luigi
    Colagrande, Stefano
    [J]. MEDICINE, 2014, 93 (06) : e40
  • [23] Feasibility of voxel-based Dose Painting for recurrent Glioblastoma guided by ADC values of Diffusion-Weighted MR imaging
    Orlandi, M.
    Botti, A.
    Sghedoni, R.
    Cagni, E.
    Ciammella, P.
    Iotti, C.
    Iori, M.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (12): : 1651 - 1658
  • [24] Diffusion Tensor Imaging in brain tumors: A study on gliomas and metastases
    Papageorgiou, T. S.
    Chourmouzi, D.
    Drevelengas, A.
    Kouskouras, K.
    Siountas, A.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (07): : 767 - 773
  • [25] Variability in Absolute Apparent Diffusion Coefficient Values across Different Platforms May Be Substantial: A Multivendor, Multi-institutional Comparison Study
    Sasaki, Makoto
    Yamada, Kei
    Watanabe, Yoshiyuki
    Matsui, Mieko
    Ida, Masahiro
    Fujiwara, Shunrou
    Shibata, Eri
    [J]. RADIOLOGY, 2008, 249 (02) : 624 - 630
  • [26] Diffusion-weighted MR imaging of the brain
    Schaefer, PW
    Grant, PE
    Gonzalez, RG
    [J]. RADIOLOGY, 2000, 217 (02) : 331 - 345
  • [27] SPIN DIFFUSION MEASUREMENTS: SPIN ECHOES IN THE PRESENCE OF A TIME-DEPENDENT FIELD GRADIENT
    STEJSKAL, EO
    TANNER, JE
    [J]. JOURNAL OF CHEMICAL PHYSICS, 1965, 42 (01) : 288 - +
  • [28] Multi-directional Anisotropy From Diffusion Orientation Distribution Functions
    Tan, Ek T.
    Marinelli, Luca
    Sperl, Jonathan I.
    Menzel, Marion I.
    Hardy, Christopher J.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 41 (03) : 841 - 850
  • [29] Diffusion-weighted imaging outside the brain: Consensus statement from an ISMRM-sponsored workshop
    Taouli, Bachir
    Beer, Ambros J.
    Chenevert, Thomas
    Collins, David
    Lehman, Constance
    Matos, Celso
    Padhani, Anwar R.
    Rosenkrantz, Andrew B.
    Shukla-Dave, Amita
    Sigmund, Eric
    Tanenbaum, Lawrence
    Thoeny, Harriet
    Thomassin-Naggara, Isabelle
    Barbieri, Sebastiano
    Corcuera-Solano, Idoia
    Orton, Matthew
    Partridge, Savannah C.
    Koh, Dow-Mu
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 44 (03) : 521 - 540
  • [30] Tofts PS, 2000, MAGN RESON MED, V43, P368, DOI 10.1002/(SICI)1522-2594(200003)43:3<368::AID-MRM8>3.0.CO