Dependence of apparent diffusion coefficient measurement on diffusion gradient direction and spatial position - A quality assurance intercomparison study of forty-four scanners for quantitative diffusion-weighted imaging

被引:35
作者
Fedeli, Luca [1 ]
Belli, Giacomo [2 ]
Ciccarone, Antonio [3 ]
Coniglio, Angela [4 ]
Esposito, Marco [5 ]
Giannelli, Marco [6 ]
Mazzoni, Lorenzo Nicola [7 ]
Nocetti, Luca [8 ]
Sghedoni, Roberto [9 ]
Tarducci, Roberto [10 ]
Altabella, Luisa [11 ]
Belligotti, Eleonora [12 ]
Benelli, Matteo [13 ]
Betti, Margherita [13 ]
Caivano, Rocchina [14 ]
Carni, Marco [15 ]
Chiappiniello, Andrea [10 ]
Cimolai, Sara [16 ]
Cretti, Fabiola [17 ]
Fulcheri, Christian [10 ]
Gasperi, Chiara [18 ]
Giacometti, Mara [19 ]
Levrero, Fabrizio [20 ]
Lizio, Domenico [21 ]
Maieron, Marta [22 ]
Marzi, Simona [23 ]
Mascaro, Lorella [24 ]
Mazzocchi, Silvia [5 ]
Meliado, Gabriele [25 ]
Morzenti, Sabrina [26 ]
Noferini, Linhsia [27 ]
Oberhofer, Nadia [28 ]
Quattrocchi, Maria Grazia [27 ]
Ricci, Alessandra [29 ]
Taddeucci, Adriana [2 ]
Tenori, Leonardo [30 ]
Luchinat, Claudio [30 ]
Gobbi, Gianni [31 ]
Gori, Cesare [1 ]
Busoni, Simone [2 ]
机构
[1] Univ Firenze, Florence, Italy
[2] AOU Careggi, Florence, Italy
[3] AOU Mayer, Florence, Italy
[4] AO Fatebene Fratelli, Rome, Italy
[5] AUSL Toscana Ctr, Florence, Italy
[6] AOU Pisana, Pisa, Italy
[7] AUSL Toscana Ctr, Pistoia, Italy
[8] AOU Policlin Modena, Modena, Italy
[9] AUSL IRCCS Reggio Emilia, Reggio Emilia, Italy
[10] AOU Perugia, Perugia, Italy
[11] Osped San Raffaele, Milan, Italy
[12] Osped Riuniti Marche Nord, Pesaro, Italy
[13] AUSL Toscana Ctr, Prato, Italy
[14] IRCCS CROB, Rionero In Vulture, PZ, Italy
[15] AOU Policlin Umberto I, Rome, Italy
[16] ULSS 2, Treviso, Italy
[17] Osped Riuniti Bergamo, Bergamo, Italy
[18] AUSL Toscana Sud Est, Arezzo, Italy
[19] Osped Riuniti, Ancona, Italy
[20] Policlin San Martino, Genoa, Italy
[21] ASST Niguarda, Milan, Italy
[22] ASUI Udine S Maria Misericordia, Udine, Italy
[23] Ist Regina Elena, Rome, Italy
[24] ASST Spedali Riuniti, Brescia, Italy
[25] AOUI Verona, Verona, Italy
[26] ASST Monza, Monza, Italy
[27] AUSL Toscana Nord Ovest, Lucca, Italy
[28] AS Alto Adige, Bolzano, Italy
[29] ASL Viterbo, Viterbo, Italy
[30] Univ Firenze, Magnet Resonance Ctr CERM, Florence, Italy
[31] Univ Perugia, Perugia, Italy
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2018年 / 55卷
关键词
MRI; PHANTOM; VALUES;
D O I
10.1016/j.ejmp.2018.09.007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To propose an MRI quality assurance procedure that can be used for routine controls and multi-centre comparison of different MR-scanners for quantitative diffusion-weighted imaging (DWI). Materials and methods: 44 MR-scanners with different field strengths (1 T, 1.5 T and 3 T) were included in the study. DWI acquisitions (b-value range 0-1000 s/mm(2)), with three different orthogonal diffusion gradient directions, were performed for each MR-scanner. All DWI acquisitions were performed by using a standard spherical plastic doped water phantom. Phantom solution ADC value and its dependence with temperature was measured using a DOSY sequence on a 600 MHz NMR spectrometer. Apparent diffusion coefficient (ADC) along each diffusion gradient direction and mean ADC were estimated, both at magnet isocentre and in six different position 50 mm away from isocentre, along positive and negative AP, RL and HF directions. Results: A good agreement was found between the nominal and measured mean ADC at isocentre: more than 90% of mean ADC measurements were within 5% from the nominal value, and the highest deviation was 11.3%. Away from isocentre, the effect of the diffusion gradient direction on ADC estimation was larger than 5% in 47% of included scanners and a spatial non uniformity larger than 5% was reported in 13% of centres. Conclusion: ADC accuracy and spatial uniformity can vary appreciably depending on MR scanner model, sequence implementation (i.e. gradient diffusion direction) and hardware characteristics. The DWI quality assurance protocol proposed in this study can be employed in order to assess the accuracy and spatial uniformity of estimated ADC values, in single-as well as multi-centre studies.
引用
收藏
页码:135 / 141
页数:7
相关论文
共 31 条
  • [1] Diffusion-Weighted Magnetic Resonance Imaging as a Cancer Biomarker: Consensus and Recommendations
    不详
    [J]. NEOPLASIA, 2009, 11 (02): : 102 - 125
  • [2] Quality Assurance Multicenter Comparison of Different MR Scanners for Quantitative Diffusion-Weighted Imaging
    Belli, Giacomo
    Busoni, Simone
    Ciccarone, Antonio
    Coniglio, Angela
    Esposito, Marco
    Giannelli, Marco
    Mazzoni, Lorenzo N.
    Nocetti, Luca
    Sghedoni, Roberto
    Tarducci, Roberto
    Zatelli, Giovanna
    Anoja, Rosa A.
    Belmonte, Gina
    Bertolino, Nicola
    Betti, Margherita
    Biagini, Cristiano
    Ciarmatori, Alberto
    Cretti, Fabiola
    Fabbri, Emma
    Fedeli, Luca
    Filice, Silvano
    Fulcheri, Christian P. L.
    Gasperi, Chiara
    Mangili, Paola A.
    Mazzocchi, Silvia
    Meliado, Gabriele
    Morzenti, Sabrina
    Noferini, Linhsia
    Oberhofer, Nadia
    Orsingher, Laura
    Paruccini, Nicoletta
    Princigalli, Goffredo
    Quattrocchi, Mariagrazia
    Rinaldi, Adele
    Scelfo, Danilo
    Freixas, Gloria Vilches
    Tenori, Leonardo
    Zucca, Ileana
    Luchinat, Claudio
    Gori, Cesare
    Gobbi, Gianni
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 43 (01) : 213 - 219
  • [3] Diffusion Coefficient Measurement Using a Temperature-Controlled Fluid for Quality Control in Multicenter Studies
    Chenevert, Thomas L.
    Galban, Craig J.
    Ivancevic, Marko K.
    Rohrer, Susan E.
    Londy, Frank J.
    Kwee, Thomas C.
    Meyer, Charles R.
    Johnson, Timothy D.
    Rehemtulla, Alnawaz
    Ross, Brian D.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 34 (04) : 983 - 987
  • [4] Intravoxel Incoherent Motion (IVIM) MR Imaging of Colorectal Liver Metastases: Are We Only Looking at Tumor Necrosis?
    Chiaradia, Melanie
    Baranes, Laurence
    Jeanne Tran Van Nhieu
    Vignaud, Alexandre
    Laurent, Alexis
    Decaens, Thomas
    Charles-Nelson, Anais
    Brugieres, Pierre
    Katsahian, Sandrine
    Djabbari, Marjane
    Deux, Jean-Francois
    Sobhani, Iradj
    Karoui, Mehdi
    Rahmouni, Alain
    Luciani, Alain
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 39 (02) : 317 - 325
  • [5] MRI features of primary hepatic lymphoma
    Colagrande, Stefano
    Calistri, Linda
    Grazzini, Giulia
    Nardi, Cosimo
    Busoni, Simone
    Morana, Giovanni
    Grazioli, Luigi
    [J]. ABDOMINAL RADIOLOGY, 2018, 43 (09) : 2277 - 2287
  • [6] Developing a quality control protocol for diffusion imaging on a clinical MRI system
    Delakis, I
    Moore, EM
    Leach, MO
    De Wilde, JP
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (08) : 1409 - 1422
  • [7] Relationship between Apparent Diffusion Coefficients and MR Spectroscopy Findings in High-Grade Gliomas
    Gadda, Davide
    Mazzoni, Lorenzo Nicola
    Pasquini, Luca
    Busoni, Simone
    Simonelli, Paolo
    Giordano, Gian Paolo
    [J]. JOURNAL OF NEUROIMAGING, 2017, 27 (01) : 128 - 134
  • [8] MR Scanner Systems Should Be Adequately Characterized in Diffusion-MRI of the Breast
    Giannelli, Marco
    Sghedoni, Roberto
    Iacconi, Chiara
    Iori, Mauro
    Traino, Antonio Claudio
    Guerrisi, Maria
    Mascalchi, Mario
    Toschi, Nicola
    Diciotti, Stefano
    [J]. PLOS ONE, 2014, 9 (01):
  • [9] Technical Note: DTI measurements of fractional anisotropy and mean diffusivity at 1.5 T: Comparison of two radiofrequency head coils with different functional designs and sensitivities
    Giannelli, Marco
    Belmonte, Gina
    Toschi, Nicola
    Pesaresi, Ilaria
    Ghedin, Piero
    Traino, Antonio Claudio
    Bartolozzi, Carlo
    Cosottini, Mirco
    [J]. MEDICAL PHYSICS, 2011, 38 (06) : 3205 - 3211
  • [10] Diffusion-MRI in neurodegenerative disorders
    Goveas, Joseph
    O'Dwyer, Laurence
    Mascalchi, Mario
    Cosottini, Mirco
    Diciotti, Stefano
    De Santis, Silvia
    Passamonti, Luca
    Tessa, Carlo
    Toschi, Nicola
    Giannelli, Marco