Push-out resistance of concrete-filled spiral-welded mild-steel and stainless-steel tubes

被引:2
作者
Loke, Chi K. [1 ]
Gunawardena, Yasoja K. R. [1 ]
Aslani, Farhad [1 ,2 ]
Uy, Brian [3 ]
机构
[1] Univ Western Australia, Sch Engn, Mat & Struct Innovat Grp, Crawley, WA 6009, Australia
[2] Edith Cowan Univ, Sch Engn, Joondalup, WA 6027, Australia
[3] Univ Sydney, Sch Civil Engn, Camperdown, NSW 2006, Australia
关键词
bond strength; push-out tests; spiral-welded tubes; mild-steel; stainless-steel; analytical models; BOND BEHAVIOR; COMPOSITE ACTION; SHORT COLUMNS; LONG COLUMNS; DESIGN;
D O I
10.12989/scs.2019.33.6.823
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Spiral welded tubes (SWTs) are fabricated by helically bending a steel plate and welding the resulting abutting edges. The cost-effectiveness of concrete-filled steel tube (CFST) columns can be enhanced by utilising such SWTs rather than the more conventional longitudinal seam welded tubes. Even though the steel-concrete interface bond strength of such concrete-filled spiral-welded steel tubes (CF-SWSTs) is an important consideration in relation to ensuring composite behaviour of such elements, especially at connections, it has not been investigated in detail to date. CF-SWSTs warrant separate consideration of their bond behaviour to CFSTs of other tube types due to the distinct weld seam geometry and fabrication induced surface imperfection patterns of SWTs. To address this research gap, axial push-out tests on forty CF-SWSTs were carried out where the effects of tube material, outside diameter (D), outside diameter to wall thickness (D/t), length of the steel-concrete interface (L) and concrete strength grade (f'(c)) were investigated. D, D/t and L/D values in the range 102-305 mm, 51-152.5 and 1.8-5.9 were considered while two nominal concrete grades, 20 MPa and 50 MPa, were used for the tests. The test results showed that the push-out bond strengths of CF-SWSTs of both mild-steel and stainless-steel were either similar to or greater than those of comparable CFSTs of other tube types. The bond strengths obtained experimentally for the tested CF-SWSTs, irrespective of the tube material type, were found to be well predicted by the guidelines contained in AISC-360.
引用
收藏
页码:823 / 836
页数:14
相关论文
共 48 条
[1]   Experimental studies on the behavior of concrete-filled steel tubes incorporating crumb rubber [J].
Abendeh, Raed ;
Ahmad, Hesham S. ;
Hunaiti, Yasser M. .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2016, 122 :251-260
[2]  
Alfawakhiri F., 1997, BEHAV HIGH STRENGTH
[3]   Incremental collapse threshold for pushout resistance of circular concrete filled steel tubular columns [J].
Aly, T. ;
Elchalakani, M. ;
Thayalan, P. ;
Patnaikuni, I. .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2010, 66 (01) :11-18
[4]  
[Anonymous], 2001, STAND STRUCT CALC ST
[5]  
[Anonymous], 2007, MECH OFFSHORE PIPELI
[6]  
[Anonymous], 2017, 23272017 ASNZS
[7]  
[Anonymous], 2016, 36016 ANSIAISC
[8]  
[Anonymous], 2007, 13912007 ASNZS
[9]  
Baskar K., 2013, INT J EARTH SCI ENG, V6, P170
[10]   Push-out test of pre-stressing concrete filled circular steel tube columns by means of expansive cement [J].
Chang Xu ;
Huang Chengkui ;
Jiang Decheng ;
Song Yuancheng .
CONSTRUCTION AND BUILDING MATERIALS, 2009, 23 (01) :491-497