Age Dependent Differences in Collagen Alignment of Glutaraldehyde Fixed Bovine Pericardium

被引:33
作者
Sizeland, Katie H.
Wells, Hannah C.
Higgins, John [1 ]
Cunanan, CrystalM. [2 ]
Kirby, Nigel [3 ]
Hawley, Adrian [3 ]
Mudie, Stephen T. [3 ]
Haverkamp, Richard G.
机构
[1] So Lights Biomat, Palmerston North 4110, New Zealand
[2] Boston Sci, Struct Heart Div, Los Gatos, CA 95032 USA
[3] Australian Synchrotron, Clayton, Vic 3168, Australia
关键词
DIGITAL FLEXOR TENDON; FIBER ORIENTATION; MECHANICAL-PROPERTIES; FIBRIL POPULATIONS; CONNECTIVE TISSUES; LIGHT-SCATTERING; DIAMETER; LEATHER; STRENGTH; IMPLANTATION;
D O I
10.1155/2014/189197
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Bovine pericardium is used for heart valve leaflet replacement where the strength and thinness are critical properties. Pericardium from neonatal animals (4-7 days old) is advantageously thinner and is considered as an alternative to that from adult animals. Here, the structures of adult and neonatal bovine pericardium tissues fixed with glutaraldehyde are characterized by synchrotron-based small angle X-ray scattering (SAXS) and compared with the mechanical properties of these materials. Significant differences are observed between adult and neonatal tissue. The glutaraldehyde fixed neonatal tissue has a higher modulus of elasticity (83.7 MPa) than adult pericardium (33.5 MPa) and a higher normalised ultimate tensile strength (32.9 MPa) than adult pericardium(19.1 MPa). Measured edge on to the tissue, the collagen in neonatal pericardium is significantly more aligned (orientation index (OI) 0.78) than that in adult pericardium (OI 0.62). There is no difference in the fibril diameter between neonatal and adult pericardium. It is shown that high alignment in the plane of the tissue provides the mechanism for the increased strength of the neonatal material. The superior strength of neonatal compared with adult tissue supports the use of neonatal bovine pericardium in heterografts.
引用
收藏
页数:10
相关论文
共 49 条
[1]   Molecular mechanisms of ageing in connective tissues [J].
Bailey, AJ .
MECHANISMS OF AGEING AND DEVELOPMENT, 2001, 122 (07) :735-755
[2]   Stress related collagen ultrastructure in human aortic valves - implications for tissue engineering [J].
Balguid, Angelique ;
Driessen, Niels J. B. ;
Mol, Anita ;
Schmitz, Joep P. J. ;
Verheyen, Fons ;
Bouten, Carlijn V. C. ;
Baaijens, Frank P. T. .
JOURNAL OF BIOMECHANICS, 2008, 41 (12) :2612-2617
[3]   Collagen Fibril Alignment and Deformation during Tensile Strain of Leather: A Small-Angle X-ray Scattering Study [J].
Basil-Jones, Melissa M. ;
Edmonds, Richard L. ;
Norris, Gillian E. ;
Haverkamp, Richard G. .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2012, 60 (05) :1201-1208
[4]   Collagen Fibril Orientation in Ovine and Bovine Leather Affects Strength: A Small Angle X-ray Scattering (SAXS) Study [J].
Basil-Jones, Melissa M. ;
Edmonds, Richard L. ;
Cooper, Sue M. ;
Haverkamp, Richard G. .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2011, 59 (18) :9972-9979
[5]   Leather Structure Determination by Small-Angle X-ray Scattering (SAXS): Cross Sections of Ovine and Bovine Leather [J].
Basil-Jones, Melissa M. ;
Edmonds, Richard L. ;
Allsop, Timothy F. ;
Cooper, Sue M. ;
Holmes, Geoff ;
Norris, Gillian E. ;
Cookson, David J. ;
Kirby, Nigel ;
Haverkamp, Richard G. .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2010, 58 (09) :5286-5291
[6]   Obesity Affects Collagen Fibril Diameter and Mechanical Properties of Tendons in Zucker Rats [J].
Biancalana, Adriano ;
Veloso, Licio A. ;
Gomes, Laurecir .
CONNECTIVE TISSUE RESEARCH, 2010, 51 (03) :171-178
[7]   COLLAGEN ORIENTATION BY X-RAY POLE FIGURES AND MECHANICAL-PROPERTIES OF MEDIA CAROTID WALL [J].
BIGI, A ;
RIPAMONTI, A ;
ROVERI, N ;
JERONIMIDIS, G ;
PURSLOW, PP .
JOURNAL OF MATERIALS SCIENCE, 1981, 16 (09) :2557-2562
[8]   Microcrimped Collagen Fiber-Elastin Composites [J].
Caves, Jeffrey M. ;
Kumar, Vivek A. ;
Xu, Wenjun ;
Naik, Nisarga ;
Allen, Mark G. ;
Chaikof, Elliot L. .
ADVANCED MATERIALS, 2010, 22 (18) :2041-+
[9]   Effects of exercise on the diameter of collagen fibrils in the central core and periphery of the superficial digital flexor tendon in foals [J].
Cherdchutham, W ;
Becker, CK ;
Spek, ER ;
Voorhout, WF ;
van Weeren, PR .
AMERICAN JOURNAL OF VETERINARY RESEARCH, 2001, 62 (10) :1563-1570
[10]   Percutaneous Transcatheter Aortic Valve Implantation: Assessing Results, Judging Outcomes, and Planning Trials The Interventionalist Perspective [J].
Chiam, Paul T. L. ;
Ruiz, Carlos E. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2008, 1 (04) :341-350