Development and studies on microstrip detector

被引:0
作者
Radhakrishna, V
Rajanna, K [1 ]
Desai, SS
Shaikh, AM
机构
[1] Indian Inst Sci, Dept Instrumentat, Bangalore 560012, Karnataka, India
[2] Bhabha Atom Res Ctr, Solid State Phys Div, Bombay 400085, Maharashtra, India
来源
CURRENT SCIENCE | 2003年 / 84卷 / 10期
关键词
D O I
暂无
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
We report development of gas microstrip detectors using thin film and lithography techniques. The detectors were tested for their performance for X-rays (5.9 keV) and a maximum gas gain of similar to 13,000 and best resolution of similar to 12% was obtained. Factors affecting gain and resolution were investigated. The detectors were tested for their one-dimensional position sensitivity. Meandering resistive strips were used for charge division method. A position resolution of 0.48 mm was obtained.
引用
收藏
页码:1327 / 1336
页数:10
相关论文
共 30 条
[1]   A MICROSTRIP GAS AVALANCHE CHAMBER WITH 2-DIMENSIONAL READOUT [J].
ANGELINI, F ;
BELLAZZINI, R ;
BREZ, A ;
MASSAI, MM ;
SPANDRE, G ;
TORQUATI, MR .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 283 (03) :755-761
[2]  
BATEMAN JE, RALTR2000022
[3]  
BATEMAN JE, RALTR1998044
[4]   Technique for the characterization of discharges in micro-strip gas chambers [J].
Bellazzini, R ;
Brez, A ;
Latronico, L ;
Lumb, N ;
Spandre, G ;
Bozzo, M ;
Cattai, A ;
Tsirou, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 398 (2-3) :426-428
[5]  
BLOUW J, 1995, P MSGC WORKSH LYON, P143
[6]   PERFORMANCE OF GAS MICROSTRIP CHAMBERS ON GLASS SUBSTRATA WITH ELECTRONIC CONDUCTIVITY [J].
BOUCLIER, R ;
MILLION, G ;
ROPELEWSKI, L ;
SAULI, F ;
PESTOV, YN ;
SHEKHTMAN, LI .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 332 (1-2) :100-106
[7]  
BUDTZJORGENSEN C, 1991, NUCL INSTRUM METHO A, V310
[8]   USE OF MULTIWIRE PROPORTIONAL COUNTERS TO SELECT AND LOCALIZE CHARGED PARTICLES [J].
CHARPAK, G ;
BOUCLIER, R ;
BRESSANI, T ;
FAVIER, J ;
ZUPANCIC, C .
NUCLEAR INSTRUMENTS & METHODS, 1968, 62 (03) :262-&
[9]   HIGH-ACCURACY, 2-DIMENSIONAL READOUT IN MULTIWIRE PROPORTIONAL CHAMBERS [J].
CHARPAK, G ;
SAULI, F .
NUCLEAR INSTRUMENTS & METHODS, 1973, 113 (03) :381-385
[10]   Operation of sealed microstrip gas chambers at the ILL [J].
Clergeau, JF ;
Convert, P ;
Feltin, D ;
Fischer, HE ;
Guerard, B ;
Hansen, T ;
Manzin, G ;
Oed, A ;
Palleau, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 471 (1-2) :60-68