A Meta-Analysis of Sutureless or Rapid-Deployment Aortic Valve Replacement

被引:7
作者
Takagi, Hisato [1 ]
Umemoto, Takuya [1 ]
机构
[1] Shizuoka Med Ctr, Dept Cardiovasc Surg, 762-1 Nagasawa, Shimizu, Shizuoka 4118611, Japan
关键词
meta-analysis; rapid-deployment aortic valve replacement; sutureless aortic valve replacement; VENTRICULAR MASS REGRESSION; SINGLE-CENTER EXPERIENCE; CLINICAL-EXPERIENCE; FOLLOW-UP; IMPLANTATION; BIOPROSTHESIS; MULTICENTER; STENOSIS; MINITHORACOTOMY; PERFORMANCE;
D O I
10.1055/s-0035-1566130
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
ObjectiveTo summarize the safety of sutureless or rapid-deployment aortic valve replacement (AVR), we performed a systematic review and meta-analysis of single-arm studies. MethodsMEDLINE and EMBASE were searched through December 2014. Studies considered for inclusion met the following criteria: the design was a single-arm study enrolling 50 participants; the study population consisted of patients undergoing sutureless/rapid-deployment AVR; and main outcomes included early (in-hospital or 30-day) mortality and/or overall survival. ResultsOf 250 potentially relevant articles screened initially, 11 eligible studies enrolling a total of 2,066 patients were identified and included. The Enable, Intuity, and Perceval bioprostheses were used in three, two, and six studies, respectively. Mean age of patients was 77.6 years, and 56.9% of patients were women. Mean logistic European System for Cardiac Operative Risk Evaluation I and II were 10.5 and 7.4%, respectively. Aortic cross-clamp times in overall patients, patients undergoing isolated AVR, those undergoing AVR with any concomitant procedures, and those undergoing AVR with coronary artery bypass grafting were 44.7, 41.9, 56.2, and 51.3 minutes, respectively. Arithmetic mean of early mortality was 2.6%, and fixed-effects combined early mortality was 3.2% (95% confidence interval, 2.5-4.2%). Arithmetic mean of 1-year survival was 89.7%, and fixed-effects combined 1-year mortality was 10.4% (9.0-12.1%). ConclusionSutureless/rapid-deployment AVR is feasible and safe with approximate 3 and 10% of early and 1-year mortality, respectively. Large-size randomized controlled trials, however, are needed to determine whether sutureless/rapid-deployment AVR improves mortality compared with conventional AVR.
引用
收藏
页码:400 / 409
页数:10
相关论文
共 50 条
[1]   Clinical experience with the second-generation 3f Enable sutureless aortic valve prosthesis [J].
Aymard, Thierry ;
Kadner, Alexander ;
Walpoth, Nazan ;
Goeber, Volkhart ;
Englberger, Lars ;
Stalder, Mario ;
Eckstein, Friedrich ;
Zobrist, Claudia ;
Carrel, Thierry .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2010, 140 (02) :313-316
[2]  
Biancari F., 2015, Heart Vessels
[3]   A Randomized Multicenter Trial of Minimally Invasive Rapid Deployment Versus Conventional Full Sternotomy Aortic Valve Replacement [J].
Borger, Michael A. ;
Moustafine, Vadim ;
Conradi, Lenard ;
Knosalla, Christoph ;
Richter, Markus ;
Merk, Denis R. ;
Doenst, Torsten ;
Hammerschmidt, Robert ;
Treede, Hendrik ;
Dohmen, Pascal ;
Strauch, Justus T. .
ANNALS OF THORACIC SURGERY, 2015, 99 (01) :17-24
[4]   Sutureless aortic valve replacement with the Trilogy Aortic Valve System: Multicenter experience [J].
Breitenbach, Ingo ;
Wimmer-Greinecker, Gerhard ;
Bockeria, Leo A. ;
Sadowski, Jerzy ;
Schmitz, Christoph ;
Kapelak, Boguslaw ;
Bartus, Krzysztof ;
Muratov, Ravil ;
Harringer, Wolfgang .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2010, 140 (04) :878-+
[5]   Perceval Sutureless Valve - are Sutureless Valves Here? [J].
Chandola, Rahul ;
Teoh, Kevin ;
Elhenawy, Abdelsalam ;
Christakis, George .
CURRENT CARDIOLOGY REVIEWS, 2015, 11 (03) :220-228
[6]  
Concistrè G, 2013, INNOVATIONS, V8, P23, DOI 10.1097/IMI.0b013e31828d6b03
[7]  
Concistrè G, 2013, J HEART VALVE DIS, V22, P817
[8]   Two Alternative Sutureless Strategies for Aortic Valve Replacement A Two-Center Experience [J].
Concistre, Giovanni ;
Santarpino, Giuseppe ;
Pfeiffer, Steffen ;
Farneti, Pierandrea ;
Miceli, Antonio ;
Chiaramonti, Francesca ;
Solinas, Marco ;
Glauber, Mattia ;
Fischlein, Theodor .
INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2013, 8 (04) :253-257
[9]   Sutureless aortic valve replacement as an alternative treatment for patients belonging to the "gray zone" between transcatheter aortic valve implantation and conventional surgery: A propensity-matched, multicenter analysis [J].
D'Onofrio, Augusto ;
Messina, Antonio ;
Lorusso, Roberto ;
Alfieri, Ottavio R. ;
Fusari, Melissa ;
Rubino, Paolo ;
Rinaldi, Mauro ;
Di Bartolomeo, Roberto ;
Glauber, Mattia ;
Troise, Giovanni ;
Gerosa, Gino .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2012, 144 (05) :1010-1018
[10]   Ministernotomy Versus Full Sternotomy Aortic Valve Replacement With a Sutureless Bioprosthesis: A Multicenter Study [J].
Dalen, Magnus ;
Biancari, Fausto ;
Rubino, Antonino S. ;
Santarpino, Giuseppe ;
De Praetere, Herbert ;
Kasama, Keiichiro ;
Juvonen, Tatu ;
Deste, Wanda ;
Pollari, Francesco ;
Meuris, Bart ;
Fischlein, Theodor ;
Mignosa, Carmelo ;
Gatti, Giuseppe ;
Pappalardo, Aniello ;
Sartipy, Ulrik ;
Svenarud, Peter .
ANNALS OF THORACIC SURGERY, 2015, 99 (02) :524-530