Evaluation of Fatigue Life for Dental Implants Using FEM Analysis

被引:16
作者
Ziaie, Babak [1 ]
Khalili, S. Mohammad Reza [1 ]
机构
[1] KN Toosi Univ Technol, Ctr Res Composite & Smart Mat & Struct, Fac Mech Engn, Tehran 1991943344, Iran
关键词
dental implant; mechanical stress; fatigue life; FEM; abutment failure; FINITE-ELEMENT-ANALYSIS; RECONSTRUCTED MANDIBULAR MODELS; STRESS-DISTRIBUTION; ABUTMENT SCREW; BONE;
D O I
10.3390/prosthesis3040028
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
The purpose of this study is to numerically analyze a 3D model of an implant under fatigue loads. A bone and a V shape implant were modeled using SolidWorks2008 software. In order to obtain an exact model, the bone was assumed as a linear orthotropic material. Mechanical loads were applied in terms of fastening torque to the abutment and mastication force applied at the top of the crown. The abutment was tightened into the implant by applying a 35 N.cm torque causing tensile stress within the abutment screw as a preload that is harmful not only for the fatigue life of the abutment, but also for the stability of the implant-abutment interface. A 700 N force at an angle of 30 degrees to the vertical direction was applied to the crown. The mechanical analysis results showed that the abutment is the critical component of the implant system in terms of fatigue failure. This is due to the fact that the tensile preloads originated from the fastening torque. The results were presented in terms of fatigue life in the abutment. Fatigue life of the abutment and implant were calculated based on the Goodman, Soderberg, Smith-Watson-Topper (SWT), and Marrow theories. According to the results of the fatigue life prediction, abutment screws may fail after about 3 x 10(5) cycles. The predicted results by the Goodman theory are at a very good accordance with the clinical data.
引用
收藏
页码:300 / 313
页数:14
相关论文
共 27 条
[1]  
Akpinar I, 1996, Quintessence Int, V27, P11
[2]   Optimal design of thread height and width on an immediately loaded cylinder implant: A finite element analysis [J].
Ao, Jianhua ;
Li, Tao ;
Liu, Yanpu ;
Ding, Yin ;
Wu, Guofeng ;
Hu, Kaijin ;
Kong, Liang .
COMPUTERS IN BIOLOGY AND MEDICINE, 2010, 40 (08) :681-686
[3]   Effects of Prosthetic Material and Framework Design on Stress Distribution in Dental Implants and Peripheral Bone: A Three-Dimensional Finite Element Analysis [J].
Arinc, Hakan .
MEDICAL SCIENCE MONITOR, 2018, 24 :4279-4287
[4]  
Branemark P I, 1977, Scand J Plast Reconstr Surg Suppl, V16, P1
[5]   Photoelastic analysis of dynamic stress distribution around short implants restored with different materials [J].
Burgoa-La-Forcada, S. M. ;
Edwards Rezende, C. E. ;
Castiglia Gonzaga, C. ;
Cesar Zielak, J. ;
Yoshio Furuse, A. .
JOURNAL OF OSSEOINTEGRATION, 2018, 10 (02) :44-49
[6]  
Chikr Y.C., 2020, NAT TECHNOL, V22, P20
[7]   Stress Distribution in Single Dental Implant System: Three-Dimensional Finite Element Analysis Based on an In Vitro Experimental Model [J].
Edwards Rezende, Carlos Eduardo ;
Chase-Diaz, Melody ;
Costa, Max Doria ;
Albarracin, Max Laurent ;
Paschoeto, Gabriela ;
Capello Sousa, Edson Antonio ;
Rubo, Jose Henrique ;
Sanches Borges, Ana Flavia .
JOURNAL OF CRANIOFACIAL SURGERY, 2015, 26 (07) :2196-2200
[8]   Maximum clenching force of patients with moderate loss of posterior tooth support: A pilot study [J].
Gibbs, CH ;
Anusavice, KJ ;
Young, HM ;
Jones, JS ;
Esquivel-Upshaw, JF .
JOURNAL OF PROSTHETIC DENTISTRY, 2002, 88 (05) :498-502
[9]   Influence of implant length and diameter on stress distribution:: A finite element analysis [J].
Himmlová, L ;
Dostálová, T ;
Kácovsky, A ;
Konvicková, S .
JOURNAL OF PROSTHETIC DENTISTRY, 2004, 91 (01) :20-25
[10]  
Holmgren E P, 1998, J Oral Implantol, V24, P80, DOI 10.1563/1548-1336(1998)024<0080:EPOODI>2.3.CO