Portable measurement system for real-time acquisition and analysis of in-vivo spatially resolved reflectance in the subdiffusive regime

被引:3
作者
Naglic, Peter [1 ]
Ivancic, Matic [1 ]
Pernus, Franjo [1 ]
Likar, Bostjan [1 ]
Burmen, Miran [1 ]
机构
[1] Univ Ljubljana, Fac Elect Engn, Trzaska Cesta 25, Ljubljana 1000, Slovenia
来源
DESIGN AND QUALITY FOR BIOMEDICAL TECHNOLOGIES XI | 2018年 / 10486卷
关键词
spatially resolved reflectance; subdiffusive; Monte Carlo; artificial neural networks; real-time; in-vivo; OPTICAL-PROPERTIES; DIFFUSE-REFLECTANCE; MONTE-CARLO; MICROSTRUCTURE; TRANSPORT; PRESSURE;
D O I
10.1117/12.2290460
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A measurement system was developed to acquire and analyze subdiffusive spatially resolved reflectance using an optical fiber probe with short source-detector separations. Since subdiffusive reflectance significantly depends on the scattering phase function, the analysis of the acquired reflectance is based on a novel inverse Monte Carlo model that allows estimation of phase function related parameters in addition to the absorption and reduced scattering coefficients. In conjunction with our measurement system, the model allowed real-time estimation of optical properties, which we demonstrate for a case of dynamically induced changes in human skin by applying pressure with an optical fiber probe.
引用
收藏
页数:7
相关论文
共 19 条
  • [1] Parallel computing with graphics processing units for high-speed Monte Carlo simulation of photon migration
    Alerstam, Erik
    Svensson, Tomas
    Andersson-Engels, Stefan
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2008, 13 (06)
  • [2] Monte Carlo study of diffuse reflectance at source-detector separations close to one transport mean free path
    Bevilacqua, F
    Depeursinge, C
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1999, 16 (12): : 2935 - 2945
  • [3] Bohren C. F., 1983, Absorption and Scattering of Light by Small Particles, DOI 10.1002/9783527618156
  • [4] Sub-diffuse optical biomarkers characterize localized microstructure and function of cortex and malignant tumor
    Bravo, Jaime J.
    Paulsen, Keith D.
    Roberts, David W.
    Kanick, Stephen C.
    [J]. OPTICS LETTERS, 2016, 41 (04) : 781 - 784
  • [5] BREGAR M, 2015, J BIOMED OPT, V20, DOI DOI 10.1117/1.JBO.20.12.127002
  • [6] Towards a field-compatible optical Spectroscopic device for cervical cancer screening in resource-limited settings: effects of calibration and pressure
    Chang, Vivide Tuan-Chyan
    Merisier, Delson
    Yu, Bing
    Walmer, David K.
    Ramanujam, Nirmala
    [J]. OPTICS EXPRESS, 2011, 19 (19): : 17908 - 17924
  • [7] Ivancic M., EFFICIENT ESTI UNPUB
  • [8] Optical properties of biological tissues: a review
    Jacques, Steven L.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (11) : R37 - R61
  • [9] Probe pressure effects on human skin diffuse reflectance and fluorescence spectroscopy measurements
    Lim, Liang
    Nichols, Brandon
    Rajaram, Narasimhan
    Tunnell, James W.
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (01)
  • [10] Wide-field quantitative imaging of tissue microstructure using sub-diffuse spatial frequency domain imaging
    McClatchy, David M., III
    Rizzo, Elizabeth J.
    Wells, Wendy A.
    Cheney, Philip P.
    Hwang, Jeeseong C.
    Paulsen, Keith D.
    Pogue, Brian W.
    Kanick, Stephen C.
    [J]. OPTICA, 2016, 3 (06): : 613 - 621