The method for leakage detection of urban natural gas pipeline based on the improved ITA and ALO

被引:7
作者
Hao, Yongmei [1 ]
Wu, Yujia [1 ]
Jiang, Juncheng [1 ,2 ]
Xing, Zhixiang [1 ]
Yang, Ke [1 ]
Wang, Shuli [1 ]
Xu, Ning [3 ]
Rao, Yongchao [1 ]
机构
[1] Changzhou Univ, Sch Environm & Safety Engn, Changzhou 213164, Jiangsu, Peoples R China
[2] Nanjing Tech Univ, Sch Safety Sci & Engn, Nanjing 211800, Jiangsu, Peoples R China
[3] Changzhou Ganghua Gas Co Ltd, Changzhou 213161, Jiangsu, Peoples R China
关键词
Urban hazardous chemicals pipeline; Segment classification method; Improved ITA method; ALO; Leakage location; INVERSE TRANSIENT ANALYSIS; MODEL; CALIBRATION; LOCATION;
D O I
10.1016/j.jlp.2021.104506
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
To solve the problems of the difficulty in early leakage monitoring and larger positioning error for urban hazardous chemicals pipelines, the optimized method based on the improved Inverse Transient Analysis (ITA) and Ant Lion Optimizer (ALO) was proposed. Firstly, based on the obtained experiment's results of leakage of natural gas in the non-metallic pipeline, the segment classification method was incorporated into the pressure gradient calculation. The modified method can adapt to the multi-node characteristics of urban pipe networks and help to obtain the preliminary positioning calculation results after optimization. Then the calculation results were embedded in the ITA calculation model. The input parameters of the gas pipeline such as boundary conditions, leakage rate and friction coefficient were used to establish the characteristic linear equations. Then the objective function of the least-squares criterion was defined, and the improved ITA model suitable for leakage detection of urban natural gas pipeline networks was constructed. Finally, the ALO was used to optimize the calculation process of the improved ITA model, and iteratively optimize the optimal friction coefficient and its corresponding minimum objective function (OF) value. As a result, a more precise location of the leakage source was calculated. The validation of the modified method is conducted by comparing the calculated values with the experiment's results. The results show that the method can accurately predict the location where the pipeline leakage occurs. The minimum error is 3.17%. Compared with the traditional ITA, this method not only accelerates the convergence speed of the objective function, but also improves the accuracy of location calculation.
引用
收藏
页数:11
相关论文
共 22 条
  • [1] Quantum-inspired ant lion optimized hybrid k-means for cluster analysis and intrusion detection
    Chen, Junwen
    Qi, Xuemei
    Chen, Linfeng
    Chen, Fulong
    Cheng, Guihua
    [J]. KNOWLEDGE-BASED SYSTEMS, 2020, 203
  • [2] A novel method for transient leakage flow rate calculation of gas transmission pipelines
    Chen, Qian
    Xing, Xiaokai
    Jin, Can
    Zuo, Lili
    Wu, Jianhang
    Wang, Weishuo
    [J]. JOURNAL OF NATURAL GAS SCIENCE AND ENGINEERING, 2020, 77
  • [3] Leak detection and location in liquid pipelines by analyzing the first transient pressure wave with unsteady friction
    Diao, Xu
    Shen, Guodong
    Jiang, Juncheng
    Chen, Qiang
    Wang, Zhirong
    Ni, Lei
    Mebarki, Ahmed
    Dou, Zhan
    [J]. JOURNAL OF LOSS PREVENTION IN THE PROCESS INDUSTRIES, 2019, 60 : 303 - 310
  • [4] Dong YH, 2002, J LOSS PREVENT PROC, V15, P423
  • [5] EFFECTIVE AND EFFICIENT GLOBAL OPTIMIZATION FOR CONCEPTUAL RAINFALL-RUNOFF MODELS
    DUAN, QY
    SOROOSHIAN, S
    GUPTA, V
    [J]. WATER RESOURCES RESEARCH, 1992, 28 (04) : 1015 - 1031
  • [6] Feng Jian, 2004, Fifth World Congress on Intelligent Control and Automation (IEEE Cat. No.04EX788), P3134
  • [7] Direct backward transient analysis for leak detection in pressurized pipelines: from theory to real application
    Haghighi, Ali
    Covas, Didia
    Ramos, Helena
    [J]. JOURNAL OF WATER SUPPLY RESEARCH AND TECHNOLOGY-AQUA, 2012, 61 (03): : 189 - 200
  • [8] Incorporation of prior information on parameters in inverse transient analysis for leak detection and roughness calibration
    Kapelan, Z.
    Savic, D. A.
    Walters, G. A.
    [J]. URBAN WATER JOURNAL, 2004, 1 (02) : 129 - 143
  • [9] A hybrid inverse transient model for leakage detection and roughness calibration in pipe networks
    Kapelan, ZS
    Savic, DA
    Walters, GA
    [J]. JOURNAL OF HYDRAULIC RESEARCH, 2003, 41 (05) : 481 - 492
  • [10] Lambert M.F, 2002, C WAT RES PLANN MAN