Regularization Analysis and Design for Prior-Image-Based X-Ray CT Reconstruction

被引:15
作者
Zhang, Hao [1 ]
Gang, Grace J. [1 ]
Dang, Hao [1 ]
Stayman, J. Webster [1 ]
机构
[1] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD 21205 USA
关键词
X-ray CT; prior-image-based reconstruction; regularization design; ITERATIVE RECONSTRUCTION; COMPUTED-TOMOGRAPHY; SPATIAL-RESOLUTION; PROJECTION; FRAMEWORK; QUALITY; CHEST;
D O I
10.1109/TMI.2018.2847250
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Prior-image-based reconstruction (PIBR) methods have demonstrated great potential for radiation dose reduction in computed tomography applications. PIBR methods take advantage of shared anatomical information between sequential scans by incorporating a patientspecific prior image into the reconstruction objective function, often as a form of regularization. However, one major challenge with PIBR methods is how to optimally determine the prior image regularization strength which balances anatomical information from the prior image with data fitting to the current measurements. Too little prior information yields limited improvements over traditional model-based iterative reconstruction, while too much prior information can force anatomical features from the prior image not supported by the measurement data, concealing true anatomical changes. In this paper, we develop quantitative measures of the bias associated with PIBR. This bias exhibits as a fractional reconstructed contrast of the difference between the prior image and current anatomy, which is quite different from traditional reconstruction biases that are typically quantified in terms of spatial resolution or artifacts. We have derived an analytical relationship between the PIBR bias and prior image regularization strength and illustrated how this relationship can be used as a predictive tool to prospectively determine prior image regularization strength to admit specific kinds of anatomical change in the reconstruction. Because bias is dependent on local statistics, we further generalized shift-variant prior image penalties that permit uniform (shift invariant) admission of anatomical changes across the imaging field of view. We validated the mathematical framework in phantom studies and compared bias predictions with estimates based on brute force exhaustive evaluation using numerous iterative reconstructions across regularization values. The experimental results demonstrate that the proposed analytical approach can predict the bias-regularization relationship accurately, allowing for prospective determination of the prior image regularization strength in PIBR. Thus, the proposed approach provides an important tool for controlling image quality of PIBR methods in a reliable, robust, and efficient fashion.
引用
收藏
页码:2675 / 2686
页数:12
相关论文
共 33 条
  • [1] Prior image constrained compressed sensing (PICCS): A method to accurately reconstruct dynamic CT images from highly undersampled projection data sets
    Chen, Guang-Hong
    Tang, Jie
    Leng, Shuai
    [J]. MEDICAL PHYSICS, 2008, 35 (02) : 660 - 663
  • [2] Time-Resolved Interventional Cardiac C-arm Cone-Beam CT: An Application of the PICCS Algorithm
    Chen, Guang-Hong
    Theriault-Lauzier, Pascal
    Tang, Jie
    Nett, Brian
    Leng, Shuai
    Zambelli, Joseph
    Qi, Zhihua
    Bevins, Nicholas
    Raval, Amish
    Reeder, Scott
    Rowley, Howard
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2012, 31 (04) : 907 - 923
  • [3] Regularization Designs for Uniform Spatial Resolution and Noise Properties in Statistical Image Reconstruction for 3-D X-ray CT
    Cho, Jang Hwan
    Fessler, Jeffrey A.
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (02) : 678 - 689
  • [4] Cho S., 2009, P SOC PHOTO-OPT INS, V7258
  • [5] dPIRPLE: a joint estimation framework for deformable registration and penalized-likelihood CT image reconstruction using prior images
    Dang, H.
    Wang, A. S.
    Sussman, Marc S.
    Siewerdsen, J. H.
    Stayman, J. W.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (17) : 4799 - 4826
  • [6] Prospective regularization design in prior-image-based reconstruction
    Dang, Hao
    Siewerdsen, Jeffrey H.
    Stayman, J. Webster
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (24) : 9515 - 9536
  • [7] Ordered subsets algorithms for transmission tomography
    Erdogan, H
    Fessler, JA
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (11) : 2835 - 2851
  • [8] Spatial resolution properties of penalized-likelihood image reconstruction: Space-invariant tomographs
    Fessler, JA
    Rogers, WL
    [J]. IEEE TRANSACTIONS ON IMAGE PROCESSING, 1996, 5 (09) : 1346 - 1358
  • [9] Prior-based artifact correction (PBAC) in computed tomography
    Heusser, Thorsten
    Brehm, Marcus
    Ritschl, Ludwig
    Sawall, Stefan
    Kachelriess, Marc
    [J]. MEDICAL PHYSICS, 2014, 41 (02)
  • [10] Lung cancer screening: Minimum tube current required for helical CT
    Itoh, S
    Ikeda, M
    Arahata, S
    Kodaira, T
    Isomura, T
    Kato, T
    Yamakawa, K
    Maruyama, K
    Ishigaki, T
    [J]. RADIOLOGY, 2000, 215 (01) : 175 - 183