Horseradish peroxidase-screen printed biosensors for determination of Ochratoxin A

被引:39
作者
Asuncion Alonso-Lomillo, M. [1 ]
Dominguez-Renedo, Olga [1 ]
del Torno-de Roman, Lorena [1 ]
Julia Arcos-Martinez, M. [1 ]
机构
[1] Univ Burgos, Fac Sci, Dept Analyt Chem, Burgos 09001, Spain
关键词
Disposable electrodes; Screen-printed enzyme; Biosensor; Ochratoxin A; GLUCOSE BIOSENSOR; CARBON INK; L-LACTATE; AMPEROMETRIC BIOSENSOR; ELECTRODES; TYROSINASE; ACID;
D O I
10.1016/j.aca.2011.01.003
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work summarizes the manufacturing procedure of Horseradish peroxidase (HRP) based biosensors for the determination of the mycotoxin Ochratoxin A (OTA). The biosensors have been fabricated using the single technology of screen-printing. That is to say, an HRP containing ink has been directly screen-printed onto carbon electrodes, which offers a higher rapidity and simplicity in the manufacturing process of biosensors for OTA determination. The formal redox potential of the Fe(III/II) moiety of HRP has been used to demonstrate the effective loading of enzyme into the ink. The chronoamperometric oxidation current registered has been successfully related to the concentration of OTA in solution from different samples, including beer ones. Under the optimum conditions of the experimental variables, precision in terms of reproducibility and repeatability has been calculated in the concentration range from 23.85 to 203.28 nM. A relative standard deviation for the slopes of 10% (n = 4) was obtained for reproducibility. In the case of repeatability, the biosensor retained a 30% of the initial sensitivity after the third calibration. The average capability of detection for 0.05% probabilities of false positive and negative was 26.77 +/- 3.61 nM (alpha = 0.05 and beta=0.05, n = 3). (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:49 / 53
页数:5
相关论文
共 36 条
[21]  
LOMILLO MAA, 2009, BIOSENSORS PROPERTIE, P1
[22]   AMPEROMETRIC GLUCOSE BIOSENSOR MANUFACTURED BY A PRINTING TECHNIQUE [J].
NAGATA, R ;
CLARK, SA ;
YOKOYAMA, K ;
TAMIYA, E ;
KARUBE, I .
ANALYTICA CHIMICA ACTA, 1995, 304 (02) :157-164
[23]   AN ENZYME-CONTAINING INK FOR SCREEN-PRINTED GLUCOSE SENSORS [J].
NAGATA, R ;
YOKOYAMA, K ;
DURLIAT, H ;
COMTAT, M ;
CLARK, SA ;
KARUBE, I .
ELECTROANALYSIS, 1995, 7 (11) :1027-1031
[24]   A GLUCOSE SENSOR FABRICATED BY THE SCREEN PRINTING TECHNIQUE [J].
NAGATA, R ;
YOKOYAMA, K ;
CLARK, SA ;
KARUBE, I .
BIOSENSORS & BIOELECTRONICS, 1995, 10 (3-4) :261-267
[25]   Electrochemical oxidation of ochratoxin A at a glassy carbon electrode and in situ evaluation of the interaction with deoxyribonucleic acid using an electrochemical deoxyribonucleic acid-biosensor [J].
Oliveira, S. C. B. ;
Diculescu, V. C. ;
Palleschi, G. ;
Compagnone, D. ;
Oliveira-Brett, A. M. .
ANALYTICA CHIMICA ACTA, 2007, 588 (02) :283-291
[26]   Fabrication of microband glucose biosensors using a screen-printing water-based carbon ink and their application in serum analysis [J].
Pemberton, R. M. ;
Pittson, R. ;
Biddle, N. ;
Hart, J. P. .
BIOSENSORS & BIOELECTRONICS, 2009, 24 (05) :1246-1252
[27]  
Rousseeuw P.J., 1989, Robust Regression and Outlier Detection, DOI [10.2307/2982847, DOI 10.2307/2982847]
[28]   DETARCHI - A PROGRAM FOR DETECTION LIMITS WITH SPECIFIED ASSURANCE PROBABILITIES AND CHARACTERISTIC CURVES OF DETECTION [J].
SARABIA, L ;
ORTIZ, MC .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1994, 13 (01) :1-6
[29]   Development, validation, and application of an acetylcholinesterase-biosensor test for the direct detection of insecticide residues in infant food [J].
Schulze, H ;
Scherbaum, E ;
Anastassiades, M ;
Vorlová, S ;
Schmid, RD ;
Bachmann, TT .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (11-12) :1095-1105
[30]   Amperometric determination of glucose with an MnO2 and glucose oxidase bulk-modified screen-printed carbon ink biosensor [J].
Turkusic, E ;
Kalcher, K ;
Schachl, K ;
Komersova, A ;
Bartos, M ;
Moderegger, H ;
Svancara, I ;
Vytras, K .
ANALYTICAL LETTERS, 2001, 34 (15) :2633-2647