Efficiency analysis for quantitative MRI of T1 and T2 relaxometry methods

被引:10
作者
Leitao, David [1 ,3 ]
Teixeira, Rui Pedro A. G. [1 ,2 ]
Price, Anthony [1 ,2 ]
Uus, Alena [1 ]
Hajnal, Joseph, V [1 ,2 ]
Malik, Shaihan J. [1 ,2 ]
机构
[1] Kings Coll London, Sch Biomed Engn & Imaging Sci, London, England
[2] Kings Coll London, Ctr Developing Brain, London, England
[3] St Thomas Hosp, Perinatal Imaging & Hlth, 1st Floor South Wing, London SE1 7EH, England
基金
英国工程与自然科学研究理事会; 英国惠康基金;
关键词
efficiency; quantitative MRI (qMRI); T1; mapping; T2; steady-state; fingerprinting (MRF); NUCLEAR-MAGNETIC-RESONANCE; STATE FREE PRECESSION; STEADY-STATE; RELAXATION-TIMES; T-1; ECHO; RECONSTRUCTION; OPTIMIZATION; SYSTEM; DESS;
D O I
10.1088/1361-6560/ac101f
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study presents a comparison of quantitative MRI methods based on an efficiency metric that quantifies their intrinsic ability to extract information about tissue parameters. Under a regime of unbiased parameter estimates, an intrinsic efficiency metric eta was derived for fully-sampled experiments which can be used to both optimize and compare sequences. Here we optimize and compare several steady-state and transient gradient-echo based qMRI methods, such as magnetic resonance fingerprinting (MRF), for joint T-1 and T-2 mapping. The impact of undersampling was also evaluated, assuming incoherent aliasing that is treated as noise by parameter estimation. In vivo validation of the efficiency metric was also performed. Transient methods such as MRF can be up to 3.5 times more efficient than steady-state methods, when spatial undersampling is ignored. If incoherent aliasing is treated as noise during least-squares parameter estimation, the efficiency is reduced in proportion to the SNR of the data, with reduction factors of 5 often seen for practical SNR levels. In vivo validation showed a very good agreement between the theoretical and experimentally predicted efficiency. This work presents and validates an efficiency metric to optimize and compare the performance of qMRI methods. Transient methods were found to be intrinsically more efficient than steady-state methods, however the effect of spatial undersampling can significantly erode this advantage.
引用
收藏
页数:11
相关论文
共 49 条
[1]   Pseudo Steady-State Free Precession for MR-Fingerprinting [J].
Asslaender, Jakob ;
Glaser, Steffen J. ;
Hennig, Juergen .
MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (03) :1151-1161
[2]   A Perspective on MR Fingerprinting [J].
Asslander, Jakob .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2021, 53 (03) :676-685
[3]   Hybrid-state free precession in nuclear magnetic resonance [J].
Asslander, Jakob ;
Novikov, Dmitry S. ;
Lattanzi, Riccardo ;
Sodickson, Daniel K. ;
Cloos, Martijn A. .
COMMUNICATIONS PHYSICS, 2019, 2 (1)
[4]   Optimized quantification of spin relaxation times in the hybrid state [J].
Asslander, Jakob ;
Lattanzi, Riccardo ;
Sodickson, Daniel K. ;
Cloos, Martijn A. .
MAGNETIC RESONANCE IN MEDICINE, 2019, 82 (04) :1385-1397
[5]   Low rank alternating direction method of multipliers reconstruction for MR fingerprinting [J].
Asslander, Jakob ;
Cloos, Martijn A. ;
Knoll, Florian ;
Sodickson, Daniel K. ;
Hennig, Juergen ;
Lattanzi, Riccardo .
MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (01) :83-96
[6]   T1 mapping with the variable flip angle technique: A simple correction for insufficient spoiling of transverse magnetization [J].
Baudrexel, Simon ;
Noeth, Ulrike ;
Schuere, Jan-Ruediger ;
Deichmann, Ralf .
MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (06) :3082-3092
[7]   What are normal relaxation times of tissues at 3 T? [J].
Bojorquez, Jorge Zavala ;
Bricq, Stephanie ;
Acquitter, Clement ;
Brunotte, Francois ;
Walker, Paul M. ;
Lalande, Alain .
MAGNETIC RESONANCE IMAGING, 2017, 35 :69-80
[8]   OPTIMAL DETERMINATION OF RELAXATION-TIMES OF FOURIER-TRANSFORM NUCLEAR MAGNETIC-RESONANCE - DETERMINATION OF SPIN-LATTICE RELAXATION-TIMES IN CHEMICALLY POLARIZED SPECIES [J].
CHRISTENSEN, KA ;
GRANT, DM ;
SCHULMAN, EM ;
WALLING, C .
JOURNAL OF PHYSICAL CHEMISTRY, 1974, 78 (19) :1971-1977
[9]   MR fingerprinting Deep RecOnstruction NEtwork (DRONE) [J].
Cohen, Ouri ;
Zhu, Bo ;
Rosen, Matthew S. .
MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (03) :885-894
[10]   A COMPARISON OF ONE-SHOT AND RECOVERY METHODS IN T1-IMAGING [J].
CRAWLEY, AP ;
HENKELMAN, RM .
MAGNETIC RESONANCE IN MEDICINE, 1988, 7 (01) :23-34