Implementation of planar proton minibeam radiation therapy using a pencil beam scanning system: A proof of concept study

被引:41
作者
De Marzi, Ludovic [1 ]
Patriarca, Annalisa [1 ]
Nauraye, Catherine [1 ]
Hierso, Eric [1 ]
Dendale, Remi [1 ]
Guardiola, Consuelo [2 ,3 ]
Prezado, Yolanda [2 ,3 ]
机构
[1] PSL Res Univ, Inst Curie, Ctr Protontherapie Orsay, Campus Univ,Batiment 101, F-91898 Orsay, France
[2] Paris 7 Univ, UMR 8165, CNRS, IMNC, 15 Rue Georges Clemenceau, F-91405 Orsay, France
[3] Paris 11 Univ, UMR 8165, CNRS, IMNC, 15 Rue Georges Clemenceau, F-91405 Orsay, France
关键词
Monte Carlo simulations; proton minibeam radiation therapy; spatial fractionation of the dose; MONTE-CARLO SIMULATIONS; RAY MICROPLANAR BEAMS; GLIOMA-BEARING RATS; CLINICAL-APPLICATIONS; ANALYTICAL-MODEL; DOSE CALCULATION; RADIOTHERAPY; VALIDATION; DOSIMETRY; BYSTANDER;
D O I
10.1002/mp.13209
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Methods Proton minibeam radiation therapy (pMBRT) is an innovative approach that combines the advantages of minibeam radiation therapy with the more precise ballistics of protons to further reduce the side effects of radiation. One of the main challenges of this approach is the generation of very narrow proton pencil beams with an adequate dose-rate to treat patients within a reasonable treatment time (several minutes) in existing clinical facilities. The aim of this study was to demonstrate the feasibility of implementing pMBRT by combining the pencil beam scanning (PBS) technique with the use of multislit collimators. This proof of concept study of pMBRT with a clinical system is intended to guide upcoming biological experiments. Monte Carlo simulations (TOPAS v3.1.p2) were used to design a suitable multislit collimator to implement planar pMBRT for conventional pencil beam scanning settings. Dose distributions (depth-dose curves, lateral profiles, Peak-to-Valley Dose Ratio (PVDR) and dose-rates) for different proton beam energies were assessed by means of Monte Carlo simulations and experimental measurements in a water tank using commercial ionization chambers and a new p-type silicon diode, the IBA RAZOR. An analytical intensity-modulated dose calculation algorithm designed to optimize the weight of individual Bragg peaks composing the field was also developed and validated. Results Conclusions Proton minibeams were then obtained using a brass multislit collimator with five slits measuring 2 cm x 400 mu m in width with a center-to-center distance of 4 mm. The measured and calculated dose distributions (depth-dose curves and lateral profiles) showed a good agreement. Spread-out Bragg peaks (SOBP) and homogeneous dose distributions around the target were obtained by means of intensity modulation of Bragg peaks, while maintaining spatial fractionation at shallow depths. Mean dose-rates of 0.12 and 0.09 Gy/s were obtained for one iso-energy layer and a SOBP conditions in the presence of multislit collimator. This study demonstrates the feasibility of implementing pMBRT on a PBS system. It also confirms the reliability of RAZOR detector for pMBRT dosimetry. This newly developed experimental methodology will support the design of future preclinical research with pMBRT.
引用
收藏
页码:5305 / 5316
页数:12
相关论文
共 54 条
  • [1] Microdosimetric measurements of a clinical proton beam with micrometer-sized solid-state detector
    Anderson, Sarah E.
    Furutani, Keith M.
    Tran, Linh T.
    Chartier, Lachlan
    Petasecca, Marco
    Lerch, Michael
    Prokopovich, Dale A.
    Reinhard, Mark
    Perevertaylo, Vladimir L.
    Rosenfeld, Anatoly B.
    Herman, Michael G.
    Beltran, Chris
    [J]. MEDICAL PHYSICS, 2017, 44 (11) : 6029 - 6037
  • [2] High dose bystander effects in spatially fractionated radiation therapy
    Asur, Rajalakshmi
    Butterworth, Karl T.
    Penagaricano, Jose A.
    Prise, Kevin M.
    Griffin, Robert J.
    [J]. CANCER LETTERS, 2015, 356 (01) : 52 - 57
  • [3] On the parametrization of lateral dose profiles in proton radiation therapy
    Bellinzona, V. E.
    Ciocca, M.
    Embriaco, A.
    Fontana, A.
    Mairani, A.
    Mori, M.
    Parodi, K.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (05): : 484 - 492
  • [4] Benchmarking Monte Carlo simulations against experimental data in clinically relevant passive scattering proton therapy beamline configurations
    Bonfrate, A.
    Farah, J.
    De Marzi, L.
    Delacroix, S.
    Constant, E.
    Herault, J.
    Clairand, I.
    [J]. RADIOPROTECTION, 2016, 51 (02) : 113 - 122
  • [5] An analytical approximation of the Bragg curve for therapeutic proton beams
    Bortfeld, T
    [J]. MEDICAL PHYSICS, 1997, 24 (12) : 2024 - 2033
  • [6] Effects of microbeam radiation therapy on normal and tumoral blood vessels
    Bouchet, Audrey
    Serduc, Raphaeel
    Laissue, Jean Albert
    Djonov, Valentin
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (06): : 634 - 641
  • [7] PREFERENTIAL EFFECT OF SYNCHROTRON MICROBEAM RADIATION THERAPY ON INTRACEREBRAL 9L GLIOSARCOMA VASCULAR NETWORKS
    Bouchet, Audrey
    Lemasson, Benjamin
    Le Duc, Geraldine
    Maisin, Cecile
    Brauer-Krisch, Elke
    Siegbahn, Erik Albert
    Renaud, Luc
    Khalil, Enam
    Remy, Chantal
    Poillot, Cathy
    Bravin, Alberto
    Laissue, Jean A.
    Barbier, Emmanuel L.
    Serduc, Raphael
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (05): : 1503 - 1512
  • [8] Monochromatic Minibeams Radiotherapy: From Healthy Tissue-Sparing Effect Studies Toward First Experimental Glioma Bearing Rats Therapy
    Deman, Pierre
    Vautrin, Mathias
    Edouard, Magali
    Stupar, Vasile
    Bobyk, Laure
    Farion, Regine
    Elleaume, Helene
    Remy, Chantal
    Barbier, Emmanuel L.
    Esteve, Francois
    Adam, Jean-Francois
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 82 (04): : E693 - E700
  • [9] Tissue-sparing effect of x-ray microplanar beams particularly in the CNS:: Is a bystander effect involved?
    Dilmanian, F. Avraham
    Qu, Yun
    Feinendegen, Ludwig E.
    Pena, Louis A.
    Bacarian, Tigran
    Henn, Fritz A.
    Kalef-Ezra, John
    Liu, Su
    Zhong, Zhong
    McDonald, John W.
    [J]. EXPERIMENTAL HEMATOLOGY, 2007, 35 (04) : 69 - 77
  • [10] Minibeam Therapy With Protons and Light Ions: Physical Feasibility and Potential to Reduce Radiation Side Effects and to Facilitate Hypofractionation
    Dilmanian, F. Avraham
    Eley, John G.
    Krishnan, Sunil
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 92 (02): : 469 - 474