Development and validation of a high-performance liquid chromatographic procedure for the determination of herbicide residues in surface and agriculture waters

被引:46
作者
Zanella, R [1 ]
Primel, EG
Gonçalves, FF
Kurz, MHS
Mistura, CM
机构
[1] Univ Fed Santa Catarina, Dept Quim, BR-97105900 Santa Maria, RS, Brazil
[2] Univ Passo Fundo, BR-99001970 Passo Fundo, RS, Brazil
来源
JOURNAL OF SEPARATION SCIENCE | 2003年 / 26卷 / 9-10期
关键词
water analysis; herbicides; HPLC; validation;
D O I
10.1002/jssc.200301309
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A procedure has been developed for the determination of quinclorac, bentazone, 2,4-D, clomazone, and propanil residues in surface and agriculture waters by SPE and HPLC-UV. The method was validated and was applied for levels between 0.1 and 0.5 g/L, after a 500-fold pre-concentration, Average recoveries ranged from 85.7 to 109.8% with overall relative standard deviations of 1.8 to 13.4%.
引用
收藏
页码:935 / 938
页数:4
相关论文
共 18 条
[1]   Monitoring of pesticide residues and their metabolites in surface and underground waters of Imathia (N. Greece) by means of solid-phase extraction disks and gas chromatography [J].
Albanis, TA ;
Hela, DG ;
Sakellarides, T ;
Konstantinou, IK .
JOURNAL OF CHROMATOGRAPHY A, 1998, 823 (1-2) :59-71
[2]   SOLID-PHASE EXTRACTION FOLLOWED BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ANALYSIS FOR MONITORING HERBICIDES IN DRINKING-WATER [J].
BALINOVA, A .
JOURNAL OF CHROMATOGRAPHY, 1993, 643 (1-2) :203-207
[3]  
Barcelo D., 1997, Trace Determination of Pesticides and Their Degradation Products in Water
[4]   AUTOMATED-DETERMINATION OF PYRETHROID INSECTICIDES IN SURFACE-WATER BY COLUMN LIQUID-CHROMATOGRAPHY WITH DIODE-ARRAY UV DETECTION, USING ONLINE MICELLE-MEDIATED SAMPLE PREPARATION [J].
BROUWER, ER ;
STRUYS, EA ;
VREULS, JJ ;
BRINKMAN, UAT .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 350 (7-9) :487-495
[5]   Validation of chromatographic methods in biomedical analysis - Viewpoint and discussion [J].
Causon, R .
JOURNAL OF CHROMATOGRAPHY B, 1997, 689 (01) :175-180
[6]   Pesticide chemical oxidation processes: an analytical approach [J].
Chiron, S ;
FernandezAlba, AR ;
Rodriguez, A .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1997, 16 (09) :518-527
[7]  
*EUR EC COMM, 1980, L2291129 EUR EC COMM
[8]   Comparison of various sample handling and analytical procedures for the monitoring of pesticides and metabolites in ground waters [J].
Fernandez-Alba, AR ;
Agüera, A ;
Contreras, M ;
Peñuela, G ;
Ferrer, I ;
Barceló, D .
JOURNAL OF CHROMATOGRAPHY A, 1998, 823 (1-2) :35-47
[9]  
Hatrik S, 1996, J CHROMATOGR A, V733, P217
[10]   Pesticide monitoring of drinking water with the help of solid-phase extraction and high-performance liquid chromatography [J].
JunkerBuchheit, A ;
Witzenbacher, M .
JOURNAL OF CHROMATOGRAPHY A, 1996, 737 (01) :67-74