Frequency of Technical Complications in Fixed Implant Prosthesis: The Effect of Prosthesis Screw Emergence Correction by Computer-Aided Design/Computer-Aided Manufacturing

被引:13
作者
Anitua, Eduardo [1 ,2 ,3 ]
Flores, Carlos [1 ]
Pinas, Laura [4 ]
Hamdan Alkhraisat, Mohammad [2 ,3 ]
机构
[1] Clin Eduardo Anitua, Oral Implantol, Vitoria, Spain
[2] UPV EHU Fdn Eduardo Anitua, Univ Inst Regenerat Med & Oral Implantol UIRMI, Vitoria, Spain
[3] BTI Biotechnol Inst, Vitoria, Spain
[4] Univ Europea Madrid, Madrid, Spain
关键词
dental prosthesis; CAD/CAM; implant-supported framework; screw retained; fixed dental prostheses; SUPPORTED RECONSTRUCTIONS; SURVIVAL; ABUTMENTS; CHANNEL; RATES;
D O I
10.1563/aaid-joi-D-17-00229
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Computer-aided design/computer-aided manufacturing (CAD-CAM) technology permits the angular correction of screw emergence into the prosthesis; however, there is lack of controlled clinical studies that assess the frequency of technical complications in angled screw channel restorations. This controlled clinical study was designed to assess technical incidences in angled screw channel restorations. Patients who underwent placement of implant prosthesis between November 2014 and December 2015 were screened. The patients were selected if they received a prosthesis with up to 308 correction of the prosthesis screw emergence and had at least 1 nonangulated prosthesis (screw retained). All prostheses were located completely/partially in the posterior region. The frequency of technical complications was the principal variable. A total of 52 patients with a mean age of 62+/-10 years participated, with a total of 110 prostheses (55 in the test group and 55 in the control group). A total of 11 technical complications occurred (7 in the test group and 4 in the control group). These differences were not statistically significant. All prostheses in both groups survived the follow-up. The correction of the screw emergence into the prosthesis has not increased the risk of technical complications in CAD-CAM implant prostheses.
引用
收藏
页码:427 / 431
页数:5
相关论文
共 19 条
[1]   The Effect of Torque Application Technique on Screw Preload of Implant-Supported Prostheses [J].
Al-Otaibi, Hanan Nejer ;
Almutairi, Ahlam ;
Alfarraj, Jawza ;
Algesadi, Wejdan .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (02) :259-263
[2]   Implant Survival and Crestal Bone Loss Around Extra-Short Implants Supporting a Fixed Denture: The Effect of Crown Height Space, Crown-to-Implant Ratio, and Offset Placement of the Prosthesis [J].
Anitua, Eduardo ;
Hamdan Alkhraist, Mohammad ;
Pinas, Laura ;
Begona, Leire ;
Orive, Gorka .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (03) :682-689
[3]   Angled implant abutments A practical application of available knowledge [J].
Cavallaro, John, Jr. ;
Greenstein, Gary .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2011, 142 (02) :150-158
[4]   A systematic review of single-tooth restorations supported by implants [J].
Creugers, NHJ ;
Kreulen, CM ;
Snoek, PA ;
de Kanter, RJAM .
JOURNAL OF DENTISTRY, 2000, 28 (04) :209-217
[5]  
Davidowitz Gary, 2011, Dent Clin North Am, V55, P559, DOI 10.1016/j.cden.2011.02.011
[6]   Load-bearing capacity of screw-retained CAD/CAM-produced titanium implant frameworks (I-Bridge®2) before and after cyclic mechanical loading [J].
Dittmer, Marc Philipp ;
Nensa, Moritz ;
Stiesch, Meike ;
Kohorst, Philipp .
JOURNAL OF APPLIED ORAL SCIENCE, 2013, 21 (04) :307-313
[7]   Osseointegrated Implant Fracture: Causes and Treatment [J].
Gealh, Walter Cristiano ;
Mazzo, Valeria ;
Barbi, Francisco ;
Camarini, Edevaldo Tadeu .
JOURNAL OF ORAL IMPLANTOLOGY, 2011, 37 (04) :499-503
[8]   Effects of impression levels and trays on the accuracy of impressions taken from angulated implants [J].
Geramipanah, Farideh ;
Sahebi, Majid ;
Davari, Maryam ;
Hajimahmoudi, Mohammadreza ;
Rakhshan, Vahid .
CLINICAL ORAL IMPLANTS RESEARCH, 2015, 26 (09) :1098-1105
[9]   Angled Screw Channel: An Alternative to Cemented Single-Implant Restorations-Three Clinical Examples [J].
Gjelvold, Bjorn ;
Sohrabi, Majid Melvin ;
Chrcanovic, Bruno Ramos .
INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2016, 29 (01) :74-76
[10]   Mechanical Complications Associated with Angled Screw Channel Restorations [J].
Greer, Anna C. ;
Hoyle, Philippa J. ;
Vere, Joseph W. ;
Wragg, Phillip F. .
INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2017, 30 (03) :258-259