Contact lens to measure individual ion concentrations in tears and applications to dry eye disease

被引:50
作者
Badugu, Ramachandram [1 ]
Jeng, Bennie H. [2 ]
Reece, E. Albert [3 ,4 ]
Lakowicz, Joseph R. [1 ]
机构
[1] Univ Maryland, Sch Med, Dept Biochem & Mol Biol, Ctr Fluorescence Spect, 725 W Lombard St, Baltimore, MD 21201 USA
[2] Univ Maryland, Sch Med, Dept Ophthalmol & Visual Sci, 419 W Redwood St,Suite 420, Baltimore, MD 21201 USA
[3] Univ Maryland, Sch Med, Dept Obstet Gynecol & Reprod Sci, 655 W Baltimore St, Baltimore, MD 21201 USA
[4] Univ Maryland, Sch Med, Dept Biochem & Mol Biol, 655 W Baltimore St, Baltimore, MD 21201 USA
关键词
Dry eye disease; Fluorescence sensors; Contact lens; Electrolytes; Chloride ion; Hydronium ion; Silicone hydrogels; Hydrogels; FLUORESCENCE DECAY KINETICS; SILICONE HYDROGELS; BILAYER THICKNESS; LACRIMAL GLAND; CHAIN-LENGTH; CHLORIDE; PROBE; WATER; PH; PERFORMANCE;
D O I
10.1016/j.ab.2017.11.014
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Dry eye disease (DED) affects millions of individuals in the United States and worldwide, and the incidence is increasing with an aging population. There is widespread agreement that the measurement of total tear osmolarity is the most reliable test, but this procedure provides only the total ionic strength and does not provide the concentration of each ionic species in tears. Here, we describe an approach to determine the individual ion concentrations in tears using modern silicone hydrogel (SiHG) contact lenses. We made pH (or H3O+, hydronium cation,/OH-, hydroxyl ion) and chloride ion (two of the important electrolytes in tear fluid) sensitive SiHG contact lenses. We attached hydrophobic C18 chains to water-soluble fluorescent probes for pH and chloride. The resulting hydrophobic ion sensitive fluorophores (H-ISF) bind strongly to SiHG lenses and could not be washed out with aqueous solutions. Both H-ISFs provide measurements which are independent of total intensity by use of wavelength-ratiometric measurements for pH or lifetime-based sensing for chloride. Our approach can be extended to fabricate a contact lens which provides measurements of the six dominant ionic species in tears. This capability will be valuable for research into the biochemical processes causing DED, which may improve the ability to diagnose the various types of DED.
引用
收藏
页码:84 / 94
页数:11
相关论文
共 98 条
[11]  
Bhavsar Ankita S, 2011, Oman J Ophthalmol, V4, P50, DOI 10.4103/0974-620X.83653
[12]   LONG-WAVELENGTH CHLORIDE-SENSITIVE FLUORESCENT INDICATORS [J].
BIWERSI, J ;
TULK, B ;
VERKMAN, AS .
ANALYTICAL BIOCHEMISTRY, 1994, 219 (01) :139-143
[13]  
Brennan Noel A, 2007, Cont Lens Anterior Eye, V30, P108
[14]  
CALHOUN D B, 1986, Proteins Structure Function and Genetics, V1, P109, DOI 10.1002/prot.340010202
[15]  
CARNEY LG, 1989, INVEST OPHTH VIS SCI, V30, P747
[16]  
Chalmers Robin L, 2006, Cont Lens Anterior Eye, V29, P25, DOI 10.1016/j.clae.2005.12.004
[17]   Towards large scale CMOS single-photon detector arrays for lab-on-chip applications [J].
Charbon, Edoardo .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2008, 41 (09)
[18]   Red edge excitation shift of a deeply embedded membrane probe: Implications in water penetration in the bilayer [J].
Chattopadhyay, A ;
Mukherjee, S .
JOURNAL OF PHYSICAL CHEMISTRY B, 1999, 103 (38) :8180-8185
[19]  
Chu S. -H., 2015, U. S. Pat. Appl. Publ., Patent No. [US 20150252194 Al 20150910, 20150252194]
[20]   SYNTHESIS AND SPECTRAL PROPERTIES OF NEW FLUORESCENT-PROBES FOR POTASSIUM [J].
CROSSLEY, R ;
GOOLAMALI, Z ;
GOSPER, JJ ;
SAMMES, PG .
JOURNAL OF THE CHEMICAL SOCIETY-PERKIN TRANSACTIONS 2, 1994, (03) :513-520