Contact lens to measure individual ion concentrations in tears and applications to dry eye disease

被引:50
作者
Badugu, Ramachandram [1 ]
Jeng, Bennie H. [2 ]
Reece, E. Albert [3 ,4 ]
Lakowicz, Joseph R. [1 ]
机构
[1] Univ Maryland, Sch Med, Dept Biochem & Mol Biol, Ctr Fluorescence Spect, 725 W Lombard St, Baltimore, MD 21201 USA
[2] Univ Maryland, Sch Med, Dept Ophthalmol & Visual Sci, 419 W Redwood St,Suite 420, Baltimore, MD 21201 USA
[3] Univ Maryland, Sch Med, Dept Obstet Gynecol & Reprod Sci, 655 W Baltimore St, Baltimore, MD 21201 USA
[4] Univ Maryland, Sch Med, Dept Biochem & Mol Biol, 655 W Baltimore St, Baltimore, MD 21201 USA
关键词
Dry eye disease; Fluorescence sensors; Contact lens; Electrolytes; Chloride ion; Hydronium ion; Silicone hydrogels; Hydrogels; FLUORESCENCE DECAY KINETICS; SILICONE HYDROGELS; BILAYER THICKNESS; LACRIMAL GLAND; CHAIN-LENGTH; CHLORIDE; PROBE; WATER; PH; PERFORMANCE;
D O I
10.1016/j.ab.2017.11.014
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Dry eye disease (DED) affects millions of individuals in the United States and worldwide, and the incidence is increasing with an aging population. There is widespread agreement that the measurement of total tear osmolarity is the most reliable test, but this procedure provides only the total ionic strength and does not provide the concentration of each ionic species in tears. Here, we describe an approach to determine the individual ion concentrations in tears using modern silicone hydrogel (SiHG) contact lenses. We made pH (or H3O+, hydronium cation,/OH-, hydroxyl ion) and chloride ion (two of the important electrolytes in tear fluid) sensitive SiHG contact lenses. We attached hydrophobic C18 chains to water-soluble fluorescent probes for pH and chloride. The resulting hydrophobic ion sensitive fluorophores (H-ISF) bind strongly to SiHG lenses and could not be washed out with aqueous solutions. Both H-ISFs provide measurements which are independent of total intensity by use of wavelength-ratiometric measurements for pH or lifetime-based sensing for chloride. Our approach can be extended to fabricate a contact lens which provides measurements of the six dominant ionic species in tears. This capability will be valuable for research into the biochemical processes causing DED, which may improve the ability to diagnose the various types of DED.
引用
收藏
页码:84 / 94
页数:11
相关论文
共 98 条
[1]   FLUORESCENCE LIFETIME DISTRIBUTIONS IN PROTEINS [J].
ALCALA, JR ;
GRATTON, E ;
PRENDERGAST, FG .
BIOPHYSICAL JOURNAL, 1987, 51 (04) :597-604
[2]  
[Anonymous], 2006, PRINCIPLES FLUORESCE, DOI DOI 10.1007/978-0-387-46312-4_8
[3]  
[Anonymous], CONTACT LENS MONTHLY, V218
[4]  
BACHMAN WG, 1985, INVEST OPHTH VIS SCI, V26, P1484
[5]   NANOSECOND RELAXATION PROCESSES IN LIPOSOMES [J].
BADEA, MG ;
DETOMA, RP ;
BRAND, L .
BIOPHYSICAL JOURNAL, 1978, 24 (01) :197-212
[6]   Wavelength-ratiometric near-physiological pH sensors based on 6-aminoquinolinium boronic acid probes [J].
Badugu, R ;
Lakowicz, JR ;
Geddes, CD .
TALANTA, 2005, 66 (03) :569-574
[7]  
BADUGU R, 2005, BIOORG MED CHEM LETT, V15, P3974
[8]   Bilayer thickness and lipid interface area in unilamellar extruded 1,2-diacylphosphatidylcholine liposomes:: a small-angle neutron scattering study [J].
Balgavy, P ;
Dubnicková, M ;
Kucerka, N ;
Kiselev, MA ;
Yaradaikin, SP ;
Uhriková, D .
BIOCHIMICA ET BIOPHYSICA ACTA-BIOMEMBRANES, 2001, 1512 (01) :40-52
[9]   Quasi-Solid Semi-Interpenetrating Polymer Networks as Electrolytes: Part I. Dependence of Physicochemical Characteristics and Ion Conduction Behavior on Matrix Composition, Cross-Link Density, Chain Length between Cross-Links, Molecular Entanglements, Charge Carrier Concentration, and Nature of Anion [J].
Bar, Nimai ;
Ramanjaneyulu, Kota ;
Basak, Pratyay .
JOURNAL OF PHYSICAL CHEMISTRY C, 2014, 118 (01) :159-174
[10]   Experimental Comparison of the High-Speed Imaging Performance of an EM-CCD and sCMOS Camera in a Dynamic Live-Cell Imaging Test Case [J].
Beier, Hope T. ;
Ibey, Bennett L. .
PLOS ONE, 2014, 9 (01)