Field verification of bed-mounted ADV meters

被引:15
|
作者
McIntyre, N. [1 ]
Marshall, M. [1 ]
机构
[1] Imperial Coll, London, England
基金
英国自然环境研究理事会;
关键词
field testing & monitoring; hydrology & water resource;
D O I
10.1680/wama.2008.161.4.199
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The accuracy of continuous-signal acoustic Doppler velocity (ADV) meters for gauging stream flows is examined, using a case study of nine bed-mounted 'Starflow' meters currently installed at a range of sites in the Pontbren catchment, Wales. The accuracy of the ADV meters was tested, under a range of velocities and depths, by comparing flow estimates with those based on a standard method of measurement with an impeller meter. The accuracy of the ADV meters was found to be poor for very low flows. For higher flows, in five concrete-lined sections, accuracy was reasonable without calibration of the ADV meter (estimates were within 20% of the current-metered flow for 68% of samples) and accuracy was good after calibration (estimates were within 20% of the current-metered flow for 93% of samples). In one natural channel, the performance after calibration was similarly good, while performance was fair to poor for two other natural channels. The predictability of the calibration results, and the reasons for the poor performance, are discussed.
引用
收藏
页码:199 / 206
页数:8
相关论文
共 50 条
  • [1] Discussion: Field verification of bed-mounted ADV meters
    McIntyre, N.
    Marshall, M.
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-WATER MANAGEMENT, 2010, 163 (02) : 100 - 102
  • [2] Bed-mounted electro magnetic meters: Assessment of the (missing) technical parameters
    Ivetic, Damjan
    Prodanovic, Dusan
    Stojadinovic, Luka
    Pavlovic, Dragutin
    FLOW MEASUREMENT AND INSTRUMENTATION, 2019, 68
  • [3] Bed-mounted Electro Magnetic meters: Implications for robust velocity measurement in Urban Drainage systems
    Ivetic, Damjan
    Prodanovic, Dusan
    Stojadinovic, Luka
    JOURNAL OF HYDROLOGY, 2018, 566 : 455 - 469
  • [4] Yield Equations for Bed-Mounted Infiltration Galleries
    Anderson, Erik I.
    JOURNAL OF IRRIGATION AND DRAINAGE ENGINEERING, 2023, 149 (10)
  • [5] A BED-MOUNTED MOBILE INTENSIVE-CARE UNIT
    RAILTON, R
    DOCKER, SRP
    MUNLEY, AJ
    RICHARDSON, W
    HARVEY, GM
    JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 1988, 12 (03) : 121 - 123
  • [6] A BED-MOUNTED UNIT FOR THE MOVEMENT OF CRITICALLY ILL PATIENTS
    PARK, GR
    JOHNSON, S
    ANAESTHESIA, 1981, 36 (06) : 624 - 626
  • [7] Effects of Bed Roughness on Flow around Bed-Mounted Cylinders in Open Channels
    Sadeque, M. A. F.
    Rajaratnam, N.
    Loewen, M. R.
    JOURNAL OF ENGINEERING MECHANICS, 2009, 135 (02) : 100 - 110
  • [8] On the disruption of the horseshoe vortex in flow past bed-mounted cylinders
    Pradhan, Tapas Kumar
    Thakurta, Abhinav
    Roussinova, Vesselina
    Balachandar, Ram
    Biswas, Nihar
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 2024,
  • [9] Effects of a spoiler attachment on the wake flow of a bed-mounted horizontal pipe
    Devi, Kalpana
    Hanmaiahgari, Prashanth Reddy
    Pu, Jaan H.
    PHYSICS OF FLUIDS, 2024, 36 (10)
  • [10] Turbulentwakes behind bed-mounted hemispheres in co-existing surfacewave
    Barman K.
    Debnath K.
    International Journal of Fluid Mechanics Research, 2017, 44 (02) : 169 - 183